文献速递神经头颈MR

功能磁共振成像与弥散张量成像在脑肿瘤手术语言区定位中的作用:与直接皮层电刺激及皮层-皮层诱发电位的验证

Functional Magnetic Resonance Imaging and Diffusion Tensor Imaging for Language Mapping in Brain Tumor Surgery: Validation With Direct Cortical Stimulation and Cortico-Cortical Evoked Potential.
PubMed 文献 · Korean J Radiol · 2023-01-01

前瞻性纳入26例Broca区附近肿瘤患者,对226个皮层位点比较术前fMRI和DTI纤维束成像与术中直接皮层电刺激(DCS)或皮层-皮层诱发电位(CCEP)的语言定位效能。以DCS为参考标准时fMRI和DTI敏感度69.2%-92.3%、特异度72.4%-96.8%;以CCEP为参考标准时敏感度≤40.0%。fMRI与DTI均阳性且一致的位点真阳性率高(DCS 81.2%,CCEP 100%),不一致时≤24.2%。

要点

  • fMRI与DTI纤维束成像对Broca区定位特异度72.4%-96.8%,以DCS为参考标准时敏感度69.2%-92.3%。
  • 以CCEP为参考标准时fMRI和DTI敏感度仅40.0%或更低,阴性结果不能排除语言功能区。
  • fMRI与DTI均阳性的位点真阳性率高(DCS 81.2%,CCEP 100%),两者不一致时≤24.2%。

核心结论

  • 与DCS相比,fMRI和DTI纤维束成像定位Broca区敏感且特异;与CCEP相比则特异但不敏感;fMRI与DTI均阳性的位点很可能为必需语言区。

研究设计与样本

  • 前瞻性研究,纳入26例(23-74岁;男:女=13:13)Broca区附近肿瘤患者,术前采用同时多层技术行fMRI和DTI纤维束成像,以术中DCS或CCEP为参考标准进行位点对位点比较,共分析226个皮层位点。

诊断标准与关键数值

  • 共分析226个皮层位点,其中DCS在100个位点实施,CCEP在166个位点实施。
  • fMRI和DTI纤维束成像的特异度范围为72.4%(63/87)至96.8%(122/126)。
  • 以DCS为参考标准,fMRI(动词生成任务除外)和DTI纤维束成像的敏感度为69.2%(9/13)至92.3%(12/13)。
  • 以CCEP为参考标准,fMRI和DTI纤维束成像的敏感度为40.0%(16/40)或更低。
  • 术前fMRI或DTI纤维束成像阳性的82个位点中,两者一致时真阳性率以DCS为参考标准为81.2%、以CCEP为参考标准为100%,两者不一致时≤24.2%。

临床应用与阅片要点

  • fMRI与DTI纤维束成像结果一致阳性时,该位点很可能为必需语言区。
  • 以CCEP为参考标准时fMRI和DTI纤维束成像敏感度低(≤40.0%),术前阴性结果不能排除语言功能区。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Functional magnetic resonance imaging (fMRI) and diffusion tensor imaging-derived tractography (DTI-t) contribute to the localization of language areas, but their accuracy remains controversial. This study aimed to investigate the diagnostic performance of preoperative fMRI and DTI-t obtained with a simultaneous multi-slice technique using intraoperative direct cortical stimulation (DCS) or corticocortical evoked potential (CCEP) as reference standards.

MATERIALS AND METHODS: This prospective study included 26 patients (23-74 years; male:female, 13:13) with tumors in the vicinity of Broca's area who underwent preoperative fMRI and DTI-t. A site-by-site comparison between preoperative (fMRI and DTI-t) and intraoperative language mapping (DCS or CCEP) was performed for 226 cortical sites to calculate the sensitivity and specificity of fMRI and DTI-t for mapping Broca's areas. For sites with positive signals on fMRI or DTI-t, the true-positive rate (TPR) was calculated based on the concordance and discordance between fMRI and DTI-t.

RESULTS: Among 226 cortical sites, DCS was performed in 100 sites and CCEP was performed in 166 sites. The specificities of fMRI and DTI-t ranged from 72.4% (63/87) to 96.8% (122/126), respectively. The sensitivities of fMRI (except for verb generation) and DTI-t were 69.2% (9/13) to 92.3% (12/13) with DCS as the reference standard, and 40.0% (16/40) or lower with CCEP as the reference standard. For sites with preoperative fMRI or DTI-t positivity (n = 82), the TPR was high when fMRI and DTI-t were concordant (81.2% and 100% using DCS and CCEP, respectively, as the reference standards) and low when fMRI and DTI-t were discordant (≤ 24.2%).

CONCLUSION: fMRI and DTI-t are sensitive and specific for mapping Broca's area compared with DCS and specific but insensitive compared with CCEP. A site with a positive signal on both fMRI and DTI-t represents a high probability of being an essential language area.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Kang KM, Kim KM, Kim IS, et al. Functional Magnetic Resonance Imaging and Diffusion Tensor Imaging for Language Mapping in Brain Tumor Surgery: Validation With Direct Cortical Stimulation and Cortico-Cortical Evoked Potential. Korean J Radiol. 2023. PMID: 37271209. doi:10.3348/kjr.2022.1001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。