文献速递骨肌技术与安全乳腺X线

使用新型成像技术对切割与未切割骨科皮质螺钉不同切割模式的放射学测定

A radiologic determination of the different screw cutting patterns in cut and uncut orthopedic cortical screws using a novel imaging technique.
PubMed 文献 · Skeletal Radiol · 2023-05-27

研究用聚氨酯泡沫块模拟皮质骨,以数字乳腺X线摄影和PACS软件测量不锈钢与钛制切割及未切割螺钉的钉道。切割后不锈钢螺钉核心直径增加0.30 mm(95%CI 0.16–0.45,p<.001),钛螺钉增加0.45 mm(95%CI 0.30–0.61,p<.001);外径无显著差异。结论为切割后螺钉钉道核心直径和螺纹模式发生变形,钛螺钉效应更明显。

要点

  • 切割后钛螺钉核心直径增加0.45 mm,不锈钢螺钉增加0.30 mm,均具高度统计学意义。
  • 切割与未切割螺钉的外径在两种材质间均无显著差异。
  • 数字乳腺X线摄影结合PACS软件可用于测量螺钉钉道直径变化。

核心结论

  • 切割后钛和不锈钢螺钉钉道均出现螺钉核心直径和螺纹模式变形,钛螺钉效应更显著。

研究设计与样本

  • 使用聚氨酯泡沫块模拟皮质骨的生物力学研究,分不锈钢和钛制切割与未切割螺钉四组,以数字乳腺X线摄影成像并用PACS软件测量,功效分析确定功效0.95、α误差0.05。

关键影像表现/征象

  • 切割不锈钢螺钉后核心直径增加0.30 mm(95%CI 0.16–0.45,p<.001)。
  • 切割钛螺钉后核心直径增加0.45 mm(95%CI 0.30–0.61,p<.001)。
  • 切割后不锈钢和钛螺钉的外径均无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: We hypothesize that cut screws will deform in a manner that increases the core and outer diameters of the screw hole compared to uncut controls, and effects will be more pronounced in titanium screws.

MATERIALS AND METHODS: We used biomechanical polyurethane foam blocks to simulate cortical bone. We organized four groups of stainless steel and titanium cut and uncut screws. Blocks were fitted with a jig to ensure perpendicular screw insertion. We imaged the blocks using digital mammography and measured them using PACS software. Power analysis determined a power of 0.95 and an alpha error of 0.05.

RESULTS: Highly statistically significant differences in core diameter were found after cutting stainless steel and titanium screws. Cutting stainless steel screws increased core diameter by 0.30 mm (95% CI, 0.16 to 0.45; p < .001). Titanium screws' core diameter increased by 0.45 mm (95% CI, 0.30 to 0.61; p < .001). No significant differences were found in the outer diameters of stainless steel and titanium screws after cutting.

CONCLUSION: Titanium and stainless steel screw tracts demonstrated screw core diameter and screw thread pattern deformation after cutting. Titanium screws demonstrated more significant effects.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Major JW, Ernst AJ, Kallevang JK, et al. A radiologic determination of the different screw cutting patterns in cut and uncut orthopedic cortical screws using a novel imaging technique. Skeletal Radiol. 2023. PMID: 37237173. doi:10.1007/s00256-023-04368-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。