文献速递乳腺乳腺X线

数字乳腺断层摄影与数字乳腺X线摄影在连续筛查轮次中的筛查表现:乳腺癌症监测联盟研究

Digital Breast Tomosynthesis versus Digital Mammography Screening Performance on Successive Screening Rounds from the Breast Cancer Surveillance Consortium.
PubMed 文献 · Radiology · 2023-01-01

该回顾性队列研究纳入乳腺癌症监测联盟58家乳腺影像机构中40-79岁接受数字乳腺断层摄影(DBT)或数字乳腺X线摄影(DM)筛查的女性,评估连续筛查轮次中的筛查结局。DBT在各轮次召回率均显著低于DM,第3轮及以上癌检出率显著高于DM,间期癌率和总晚期癌率无显著差异。

要点

  • DBT筛查召回率在各轮次均低于DM,第1轮差异-3.3%,第2轮-1.8%,第3轮及以上-1.2%。
  • 仅第3轮及以上DBT癌检出率显著高于DM,每1000次检查差异0.6(95%CI:0.2,1.1)。
  • DBT与DM的间期癌率和总晚期癌率在各轮次均无显著差异。

核心结论

  • 在三个筛查轮次中,DBT召回率低于DM,可能有助于检出更多癌症,间期癌率与晚期癌率无差异。

研究设计与样本

  • 回顾性队列研究,纳入乳腺癌症监测联盟58家乳腺影像机构2011至2020年40-79岁接受DBT或DM筛查的女性,共评估504863名女性的523485次DBT检查和1008123次DM检查。

诊断标准与关键数值

  • 采用广义估计方程与边际标准化调整不同检查方式和轮次间女性风险特征差异,估计筛查结局的绝对差异。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Prior cross-sectional studies have observed that breast cancer screening with digital breast tomosynthesis (DBT) has a lower recall rate and higher cancer detection rate compared with digital mammography (DM). Purpose To evaluate breast cancer screening outcomes with DBT versus DM on successive screening rounds. Materials and Methods In this retrospective cohort study, data from 58 breast imaging facilities in the Breast Cancer Surveillance Consortium were collected. Analysis included women aged 40-79 years undergoing DBT or DM screening from 2011 to 2020. Absolute differences in screening outcomes by modality and screening round were estimated during the study period by using generalized estimating equations with marginal standardization to adjust for differences in women's risk characteristics across modality and round. Results A total of 523 485 DBT examinations (mean age of women, 58.7 years ± 9.7 [SD]) and 1 008 123 DM examinations (mean age, 58.4 years ± 9.8) among 504 863 women were evaluated. DBT and DM recall rates decreased with successive screening round, but absolute recall rates in each round were significantly lower with DBT versus DM (round 1 difference, -3.3% [95% CI: -4.6, -2.1] [P < .001]; round 2 difference, -1.8% [95% CI: -2.9, -0.7] [P = .003]; round 3 or above difference, -1.2% [95% CI: -2.4, -0.1] [P = .03]). DBT had significantly higher cancer detection (difference, 0.6 per 1000 examinations [95% CI: 0.2, 1.1]; P = .009) compared with DM only for round 3 and above. There were no significant differences in interval cancer rate (round 1 difference, 0.00 per 1000 examinations [95% CI: -0.24, 0.30] [P = .96]; round 2 or above difference, 0.04 [95% CI: -0.19, 0.31] [P = .76]) or total advanced cancer rate (round 1 difference, 0.00 per 1000 examinations [95% CI: -0.15, 0.19] [P = .94]; round 2 or above difference, -0.06 [95% CI: -0.18, 0.11] [P = .43]). Conclusion DBT had lower recall rates and could help detect more cancers than DM across three screening rounds, with no difference in interval or advanced cancer rates. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Skaane in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Sprague BL, Coley RY, Lowry KP, et al. Digital Breast Tomosynthesis versus Digital Mammography Screening Performance on Successive Screening Rounds from the Breast Cancer Surveillance Consortium. Radiology. 2023. PMID: 37249433. doi:10.1148/radiol.223142

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。