文献速递妇产影像儿科影像技术与安全US

胎儿超声检查实时人工智能诊断辅助系统的开发与临床验证

Development and clinical validation of real-time artificial intelligence diagnostic companion for fetal ultrasound examination.
PubMed 文献 · Ultrasound Obstet Gynecol · 2023-01-01

本研究在来自法国和英国两个转诊中心的549例围产期表型数据库上验证了一款实时决策支持系统(DSS),该系统在胎儿超声检查每一步提示下一个应评估的表型特征以优化诊断路径。全表型输入和逐步输入下,确诊诊断位于软件前10位鉴别诊断的比例分别为93%和83%,敏感度分别为99%和84%,特异度分别为94%和96%。作者认为该软件在真实数据中表现良好,可能改善围产期保健。

要点

  • 全表型输入时93%的确诊诊断位于DSS前10位鉴别诊断,逐步输入时为83%。
  • 全表型输入敏感度99%、特异度94%;逐步输入敏感度84%、特异度96%。
  • 逐步输入平均需13次查询达到最终诊断集合。

核心结论

  • 该DSS应用于真实世界数据时表现良好,作者认为此类软件可改善围产期保健,高效地向参与超声产前诊断的医护人员提供复杂且易被忽视的知识。

研究设计与样本

  • 验证研究,基于两个转诊中心(法国一个、英国一个)收集的549例围产期表型数据库,由软件回顾性评估,采用全表型单次输入或按软件提示逐步输入表型特征两种方式,不一致病例由外部专家小组裁定。

诊断标准与关键数值

  • 全表型输入:确诊诊断位于软件前10位鉴别诊断的比例为93%,敏感度99%,特异度94%。
  • 逐步输入:确诊诊断位于软件前10位鉴别诊断的比例为83%,敏感度84%,特异度96%。
  • 逐步输入平均需13次查询达到最终诊断集合。
  • 数据集覆盖软件数据库中110/408(27%)的诊断,累积患病率83%。

临床应用与阅片要点

  • 软件在每步检查时提示下一个应评估的表型特征,以优化诊断路径至最少可能诊断数。
  • 全表型输入与逐步输入在敏感度和特异度上存在差异,报告时需注明输入方式。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Prenatal diagnosis of a rare disease on ultrasound relies on a physician's ability to remember an intractable amount of knowledge. We developed a real-time decision support system (DSS) that suggests, at each step of the examination, the next phenotypic feature to assess, optimizing the diagnostic pathway to the smallest number of possible diagnoses. The objective of this study was to evaluate the performance of this real-time DSS using clinical data.

METHODS: This validation study was conducted on a database of 549 perinatal phenotypes collected from two referral centers (one in France and one in the UK). Inclusion criteria were: at least one anomaly was visible on fetal ultrasound after 11 weeks' gestation; the anomaly was confirmed postnatally; an associated rare disease was confirmed or ruled out based on postnatal/postmortem investigation, including physical examination, genetic testing and imaging; and, when confirmed, the syndrome was known by the DSS software. The cases were assessed retrospectively by the software, using either the full phenotype as a single input, or a stepwise input of phenotypic features, as prompted by the software, mimicking its use in a real-life clinical setting. Adjudication of discordant cases, in which there was disagreement between the DSS output and the postnatally confirmed ('ascertained') diagnosis, was performed by a panel of external experts. The proportion of ascertained diagnoses within the software's top-10 differential diagnoses output was evaluated, as well as the sensitivity and specificity of the software to select correctly as its best guess a syndromic or isolated condition.

RESULTS: The dataset covered 110/408 (27%) diagnoses within the software's database, yielding a cumulative prevalence of 83%. For syndromic cases, the ascertained diagnosis was within the top-10 list in 93% and 83% of cases using the full-phenotype and stepwise input, respectively, after adjudication. The full-phenotype and stepwise approaches were associated, respectively, with a specificity of 94% and 96% and a sensitivity of 99% and 84%. The stepwise approach required an average of 13 queries to reach the final set of diagnoses.

CONCLUSIONS: The DSS showed high performance when applied to real-world data. This validation study suggests that such software can improve perinatal care, efficiently providing complex and otherwise overlooked knowledge to care-providers involved in ultrasound-based prenatal diagnosis. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Stirnemann JJ, Besson R, Spaggiari E, et al. Development and clinical validation of real-time artificial intelligence diagnostic companion for fetal ultrasound examination. Ultrasound Obstet Gynecol. 2023. PMID: 37161503. doi:10.1002/uog.26242

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。