文献速递心血管MR

双平面面积-长度法与心脏MRI三维容积定量评估心房颤动患者左心房容积的比较

Comparison of Biplane Area-Length Method and 3D Volume Quantification by Using Cardiac MRI for Assessment of Left Atrial Volume in Atrial Fibrillation.
PubMed 文献 · Radiol Cardiothorac Imaging · 2023-04-13

回顾性纳入64例心房颤动患者,比较双平面面积-长度法(BAL)测量的最大左心房容积(BALmax)与三维晚期钆增强MRI(3D LGE MRI)及三维对比增强MR血管成像(3D CE-MRA)容积定量的差异。BALmax较3D CE-MRA低估23.5 mL(P < .001),较3D LGE MRI低估31.3 mL(P < .001);3D LGE MRI与3D CE-MRA间无显著差异(P = .38)。提示BAL的椭球几何假设不能反映心房颤动患者的左心房几何形态。

要点

  • 在心房颤动患者中,BALmax较3D CE-MRA低估左心房容积(偏倚-23.5 mL,P < .001)。
  • BALmax较3D LGE MRI低估左心房容积(偏倚-31.3 mL,P < .001)。
  • 3D LGE MRI与3D CE-MRA测量的左心房容积无显著差异(偏倚7.8 mL,P = .38)。

核心结论

  • 在心房颤动患者中,BALmax较3D LGE MRI和3D CE-MRA低估左心房容积,提示BAL的椭球几何假设不能反映心房颤动患者的左心房几何形态。

研究设计与样本

  • 回顾性纳入2018年10月至2021年2月前瞻性队列中的64例心房颤动患者(平均年龄63岁±9,40例男性),所有患者接受研究性MRI检查,包括标准两腔和四腔 cine 采集、3D CE-MRA及心房收缩前进行的3D LGE MRI。

诊断标准与关键数值

  • BALmax从BAL容积-时间曲线提取,与3D CE-MRA和3D LGE MRI的LAV比较;BALmax较3D CE-MRA偏倚-23.5 mL±46.2(P < .001),较3D LGE MRI偏倚-31.3 mL±58.3(P < .001);3D LGE MRI与3D CE-MRA偏倚7.8 mL±45.7(P = .38);观察者间一致性ICC为0.96-0.98。

临床应用与阅片要点

  • 在心房颤动患者中,采用BAL法测量左心房容积时需注意其较3D LGE MRI和3D CE-MRA存在低估,3D LGE MRI与3D CE-MRA测量结果间无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare maximum left atrial (LA) volume (LAV) from the routinely used biplane area-length (BAL) method with three-dimensional (3D)-based volumetry from late gadolinium-enhanced MRI (3D LGE MRI) and contrast-enhanced MR angiography (3D CE-MRA) in patients with atrial fibrillation (AF).

MATERIALS AND METHODS: Sixty-four patients with AF (mean age, 63 years ± 9 [SD]; 40 male patients) were retrospectively included from a prospective cohort acquired between October 2018 and February 2021. All patients underwent a research MRI examination that included standard two- and four-chamber cine acquisitions, 3D CE-MRA, and 3D LGE MRI performed prior to the atrial kick. Contour delineation on cine imaging and LA 3D segmentations were performed by a radiologist. Maximum LAV (BALmax) was extracted from the BAL volume-time curve and compared with LAV from 3D CE-MRA and 3D LGE MRI. The Kruskal-Wallis test was performed, followed by the Dunn post hoc test and Bland-Altman analyses. Interobserver variability was assessed in 10 patients.

RESULTS: BALmax underestimated LAV compared with 3D CE-MRA (bias: -23.5 mL ± 46.2, P < .001) and 3D LGE MRI (bias: -31.3 mL ± 58.3, P < .001), whereas 3D LGE MRI volumes showed no evidence of a difference from 3D CE-MRA (bias: 7.8 mL ± 45.7, P = .38). Interobserver variability yielded excellent agreement for each method (intraclass correlation coefficient, 0.96-0.98).

CONCLUSION: BALmax underestimated LAV in patients with AF compared with 3D LGE MRI and 3D CE-MRA, suggesting that the geometric assumption of an ellipsoidal LA shape in BAL does not reflect LA geometry in patients with AF.Keywords: Left Atrial Volume, Biplane Area-Length, Late Gadolinium-enhanced 3D MRI, Contrast-enhanced 3D MR Angiography, Atrial Fibrillation Supplemental material is available for this article. © RSNA, 2023.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Maroun A, Baraboo JJ, Gunasekaran S, et al. Comparison of Biplane Area-Length Method and 3D Volume Quantification by Using Cardiac MRI for Assessment of Left Atrial Volume in Atrial Fibrillation. Radiol Cardiothorac Imaging. 2023. PMID: 37124639. doi:10.1148/ryct.220133

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。