斑块及斑块周围冠状动脉周围脂肪组织CT衰减值与斑块特征的相关性
回顾性纳入2021年3月至11月间188例稳定型冠心病患者的280个病灶,计算斑块及斑块周围(近端和远端5 mm与10 mm范围内)冠状动脉周围脂肪组织CT衰减值,采用多元线性回归评估其与斑块特征的相关性。结果显示斑块及斑块周围PCAT CT衰减值在非钙化斑块和混合斑块中高于钙化斑块,远端斑块高于近端斑块,且非钙化斑块、混合斑块和远端位置是PCAT CT衰减值的显著决定因素。
要点
- 非钙化斑块和混合斑块的斑块及斑块周围PCAT CT衰减值高于钙化斑块(均p<0.05)。
- 远端斑块的PCAT CT衰减值高于近端斑块(均p<0.05)。
- 非钙化斑块、混合斑块和远端位置是PCAT CT衰减值的显著决定因素(均p<0.05)。
核心结论
- 斑块及斑块周围的PCAT CT衰减值与斑块类型和位置相关。
研究设计与样本
- 回顾性收集2021年3月至2021年11月间188例稳定型冠心病患者(280个病灶)的冠状动脉CT血管成像数据,计算斑块及斑块周围(近端和远端5 mm与10 mm范围内)的PCAT CT衰减值,采用多元线性回归评估其与不同斑块特征的相关性。
关键影像表现/征象
- 非钙化斑块的斑块及斑块周围PCAT CT衰减值分别为-73.38 ± 10.41 HU、-76.77 ± 10.86 HU、79.33 ± 11.13 HU、-75.67 ± 11.24 HU、-78.63 ± 12.09 HU。
- 混合斑块的斑块及斑块周围PCAT CT衰减值分别为-76.83 ± 8.11 HU、-79 [-85, -68.5] HU、-78.55 ± 11 HU、-78.76 ± 9.9 HU、-78.79 ± 11.06 HU。
- 钙化斑块的斑块及斑块周围PCAT CT衰减值分别为-86.96 ± 10 HU、-84 [-92, -76] HU、-84.14 ± 11.08 HU、-84.91 ± 11.41 HU、-84.59 ± 11.69 HU;非钙化斑块和混合斑块的上述值均高于钙化斑块(均p<0.05)。
- 远端斑块的PCAT CT衰减值高于近端斑块(均p<0.05)。
- 最小狭窄斑块的斑块PCAT CT衰减值低于轻度或中度狭窄斑块(p<0.05)。
临床应用与阅片要点
- 非钙化斑块、混合斑块和远端位置是PCAT CT衰减值的显著决定因素(均p<0.05),阅片时可结合斑块类型和位置解读PCAT CT衰减值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To investigate the relationship between different plaque characteristics and pericoronary adipose tissue (PCAT) computed tomography (CT) attenuation values for plaques and periplaques.
MATERIALS AND METHODS: The data from 188 eligible patients with stable coronary heart disease (280 lesions) who underwent coronary CT angiography between March 2021 and November 2021 were collected retrospectively. All PCAT CT attenuation values of plaques and periplaques (the area within 5 and 10 mm proximal and distal to the plaque) were calculated, and multiple linear regression was used to assess their correlation with different plaque characteristics.
RESULTS: PCAT CT attenuation of plaques and periplaques was higher in non-calcified plaques (-73.38 ± 10.41 HU, -76.77 ± 10.86 HU, 79.33 ± 11.13 HU, -75.67 ± 11.24 HU, -78.63 ± 12.09 HU) and mixed plaques (-76.83 ± 8.11 HU, -79 [-85, -68.5] HU, -78.55 ± 11 HU, -78.76 ± 9.9 HU, -78.79 ± 11.06 HU) than in calcified plaques (-86.96 ± 10 HU, -84 [-92, -76] HU, -84.14 ± 11.08 HU, -84.91 ± 11.41 HU, -84.59 ± 11.69 HU; all p<0.05) and higher in distal segment plaques than in proximal segment plaques (all p<0.05). Plaque PCAT CT attenuation was lower in plaques with minimal stenosis than in plaques with mild or moderate stenosis (p<0.05). The significant determinants of PCAT CT attenuation values of plaques and periplaques were non-calcified plaques, mixed plaques, and plaques located in the distal segment (all p<0.05).
CONCLUSIONS: PCAT CT attenuation values in both plaques and periplaques were related to plaque type and location.