全自动人工智能身体成分工具的技术充分性:在异构外部CT检查样本中的评估

Technical Adequacy of Fully Automated Artificial Intelligence Body Composition Tools: Assessment in a Heterogeneous Sample of External CT Examinations.
PubMed 文献 · AJR Am J Roentgenol · 2023-02-22

本回顾性研究纳入来自777家外部机构的11,699例腹部CT检查,评估三种自动AI身体成分工具的技术充分性,结果显示总体充分率为97.7%,失败主要与DICOM头信息体素尺寸错误导致的各向异性误差有关。

要点

  • 三种AI工具总体技术充分率为97.7%,至少一种工具失败占2.3%。
  • 骨、肌肉、脂肪工具单独充分率分别为97.8%、99.1%、98.9%。
  • 各向异性误差是全部工具失败的最常见具体原因,且均发生于同一制造商扫描仪。

核心结论

  • 自动AI身体成分工具在异构外部CT检查样本中具有高技术充分性,支持其通用性和广泛使用潜力。

研究设计与样本

  • 回顾性研究纳入8949例患者(4256男,4693女;平均年龄55.5±15.9岁)的11,699例腹部CT检查,来自777家外部机构、83种扫描仪型号、六家制造商,图像传输至本地PACS;评估三种独立自动AI工具,每例检查评估一个轴位序列。

诊断标准与关键数值

  • 技术充分性定义为工具输出值在经验推导的参考范围内;失败即工具输出超出参考范围。

临床应用与阅片要点

  • 各向异性误差(因DICOM头信息体素尺寸信息不正确)是全部工具失败的最常见具体原因,骨工具31.6%、肌肉工具81.0%、脂肪工具62.8%;81例(88.0%)全部工具失败的检查中由该误差导致,且该误差发生时全部工具均失败;79/81(97.5%)各向异性误差发生于同一制造商扫描仪,80/81(98.8%)发生于同一扫描仪型号。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. Clinically usable artificial intelligence (AI) tools analyzing imaging studies should be robust to expected variations in study parameters. OBJECTIVE. The purposes of this study were to assess the technical adequacy of a set of automated AI abdominal CT body composition tools in a heterogeneous sample of external CT examinations performed outside of the authors' hospital system and to explore possible causes of tool failure. METHODS. This retrospective study included 8949 patients (4256 men, 4693 women; mean age, 55.5 ± 15.9 years) who underwent 11,699 abdominal CT examinations performed at 777 unique external institutions with 83 unique scanner models from six manufacturers with images subsequently transferred to the local PACS for clinical purposes. Three independent automated AI tools were deployed to assess body composition (bone attenuation, amount and attenuation of muscle, amount of visceral and sub-cutaneous fat). One axial series per examination was evaluated. Technical adequacy was defined as tool output values within empirically derived reference ranges. Failures (i.e., tool output outside of reference range) were reviewed to identify possible causes. RESULTS. All three tools were technically adequate in 11,431 of 11,699 (97.7%) examinations. At least one tool failed in 268 (2.3%) of the examinations. Individual adequacy rates were 97.8% for the bone tool, 99.1% for the muscle tool, and 98.9% for the fat tool. A single type of image processing error (anisometry error, due to incorrect DICOM header voxel dimension information) accounted for 81 of 92 (88.0%) examinations in which all three tools failed, and all three tools failed whenever this error occurred. Anisometry error was the most common specific cause of failure of all tools (bone, 31.6%; muscle, 81.0%; fat, 62.8%). A total of 79 of 81 (97.5%) anisometry errors occurred on scanners from a single manufacturer; 80 of 81 (98.8%) occurred on the same scanner model. No cause of failure was identified for 59.4% of failures of the bone tool, 16.0% of failures of the muscle tool, or 34.9% of failures of the fat tool. CONCLUSION. The automated AI body composition tools had high technical adequacy rates in a heterogeneous sample of external CT examinations, supporting the generalizability of the tools and their potential for broad use. CLINICAL IMPACT. Certain causes of AI tool failure related to technical factors may be largely preventable through use of proper acquisition and reconstruction protocols.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Pooler BD, Garrett JW, Southard AM, et al. Technical Adequacy of Fully Automated Artificial Intelligence Body Composition Tools: Assessment in a Heterogeneous Sample of External CT Examinations. AJR Am J Roentgenol. 2023. PMID: 37095663. doi:10.2214/AJR.22.28745

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。