扩散加权MRI预测和评估结直肠癌肝转移治疗反应——系统综述与Meta分析
该系统综述与Meta分析纳入16项研究,评估DWI在预测和评估结直肠癌肝转移治疗反应中的作用。采用传统单指数法计算的较低基线ADC值是最一致的反应预测因子;因异质性未能确定ADC截断值,但汇总显示反应者与非反应者平均差为-0.12×10⁻³ mm²/s。作者认为扩散衍生技术可能有助于评估和预测治疗反应,需进一步对照前瞻性研究确认。
要点
- 采用传统单指数法计算的较低基线ADC值是最一致的治疗反应预测因子。
- 因研究间异质性,Meta分析未能确立预测有利反应的ADC截断值。
- 反应者与非反应者ADC汇总平均差为-0.12×10⁻³ mm²/s。
核心结论
- 扩散衍生技术和系数可能有助于评估和预测结直肠癌肝转移的治疗反应,需进一步对照前瞻性研究确认。
研究设计与样本
- 系统综述与Meta分析,检索MEDLINE/PubMed数据库,用QUADAS-2工具评估偏倚风险,共纳入16项研究,汇总反应者与非反应者的平均差。
诊断标准与关键数值
- 采用传统单指数法计算的较低基线ADC值是最一致的反应预测因子;因异质性未能建立ADC截断值,反应者与非反应者汇总平均差为-0.12×10⁻³ mm²/s。
临床应用与阅片要点
- 作者认为扩散衍生技术和系数可能有助于结直肠癌肝转移治疗反应的评估和预测,需进一步对照前瞻性研究确认以指导临床和影像决策。
局限性
- 研究间存在异质性,Meta分析未能确立ADC截断值。
- 研究间存在差异。
- 需进一步对照前瞻性研究确认这些发现并指导临床和影像决策。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The evaluation of response to chemotherapy and targeted therapies in colorectal liver metastases has traditionally been based on size changes, as per the RECIST criteria. However, therapy may alter tissue composition and not only tumor size, therefore, functional imaging techniques such as diffusion-weighted magnetic resonance imaging (DWI) may offer a more comprehensive assessment of treatment response. The aim of this systematic review and meta-analysis was to evaluate the use of DWI in the prediction and assessment of response to treatment in colorectal liver metastases and to determine if there is a baseline apparent diffusion coefficient (ADC) cut-off value that can predict a favorable response. A literature search was conducted using the MEDLINE/PubMed database, and risk of bias was evaluated using the QUADAS-2 tool. The mean differences between responders and non-responders were pooled. A total of 16 studies met the inclusion criteria, and various diffusion-derived techniques and coefficients were found to have potential for predicting and assessing treatment response. However, discrepancies were noted between studies. The most consistent predictor of response was a lower baseline ADC value calculated using traditional mono-exponential methods. Non-mono-exponential techniques for calculating DWI-derived parameters were also reported. A meta-analysis of a subset of studies failed to establish a cut-off value of ADC due to heterogeneity, but revealed a pooled mean difference of -0.12 × 10-3 mm2/s between responders and non-responders. The results of this systematic review suggest that diffusion-derived techniques and coefficients may contribute to the evaluation and prediction of treatment response in colorectal liver metastases. Further controlled prospective studies are needed to confirm these findings and to guide clinical and radiological decision-making in the management of patients with CRC liver metastases.
引用
- Sobeh T, Inbar Y, Apter S, et al. Diffusion-weighted MRI for predicting and assessing treatment response of liver metastases from CRC - A systematic review and meta-analysis. Eur J Radiol. 2023. PMID: 37075628. doi:10.1016/j.ejrad.2023.110810
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。