绵羊模型中胎儿对人工胎盘连接的急性心血管适应

Acute fetal cardiovascular adaptation to artificial placenta in sheep model.
PubMed 文献 · Ultrasound Obstet Gynecol · 2023-01-01

该实验研究对12只胎羊在109-117天胎龄连接无泵性人工胎盘系统,采用超声和侵入性血流动力学评估连接前后的急性心血管适应。连接后脐动脉和静脉导管搏动指数降低、脐静脉峰值流速升高且血流变为搏动性,动脉和静脉压短暂升高,胎心率短暂增快,但心脏结构和功能基本保持。作者认为该系统导致非生理性静脉压升高和搏动性血流,应予以纠正以避免后期心功能损害。

要点

  • 连接人工胎盘后脐动脉和静脉导管搏动指数降低、脐静脉峰值流速升高且血流变为搏动性。
  • 连接后动脉压和静脉压短暂升高,胎心率短暂增快,右室面积变化分数无显著变化。
  • 作者认为应纠正人工胎盘系统导致的非生理性静脉压升高和搏动性血流。

核心结论

  • 连接人工胎盘系统引起胎儿短暂的血流动力学反应,数小时内趋于正常化;短期评估中心脏结构和功能保持,但系统导致非生理性静脉压升高和搏动性血流,应予以纠正以避免后期心功能损害。

研究设计与样本

  • 实验研究,12只胎羊在109-117天胎龄转移至无泵性回路经脐带连接的人工胎盘系统;第一组连续6只置入血管内导管和血管周围探头获取侵入性生理数据(设计存活目标1-3小时),第二组6只未置管(实验目标存活3-24小时);采用超声和侵入性及非侵入性血流动力学评估,多数胎儿可获得超声心动图及回路传感器记录。

诊断标准与关键数值

  • 连接后30和180分钟脐动脉搏动指数较宫内降低:宫内中位数1.36(IQR 1.06-1.50)vs 30分钟0.38(IQR 0.31-0.50)vs 180分钟0.36(IQR 0.29-0.41),极端时间点P<0.001。
  • 连接后30和180分钟静脉导管搏动指数较宫内降低:宫内中位数0.50(IQR 0.41-0.67)vs 30分钟0.29(IQR 0.22-0.33)vs 180分钟0.36(IQR 0.22-0.41),极端时间点P=0.011。
  • 连接后30和180分钟脐静脉峰值流速较宫内升高:宫内中位数20 cm/s(IQR 18-22 cm/s)vs 30分钟39 cm/s(IQR 31-43 cm/s)vs 180分钟43 cm/s(IQR 34-54 cm/s),极端时间点P<0.001,血流变为更具搏动性。
  • 平均动脉压基线、5分钟和30分钟中位数分别为43 mmHg(IQR 35-54 mmHg)、72 mmHg(IQR 61-77 mmHg)和58 mmHg(IQR 50-64 mmHg),基线 vs 5分钟P=0.02。
  • 胎心率宫内、连接后30和180分钟中位数分别为145 bpm(IQR 142-156 bpm)、188 bpm(IQR 171-209 bpm)和175 bpm(IQR 165-190 bpm),极端时间点P=0.001;右室面积变化分数分别为36%(IQR 34-41%)、38%(IQR 30-40%)和37%(IQR 33-40%),极端时间点P=0.807。

局限性

  • 第一组实验设计存活目标为1-3小时,第二组实验目标存活3-24小时,均为短期评估。
  • 作者指出系统导致非生理性静脉压升高和搏动性血流,应予以纠正以避免后期心功能损害。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To describe the acute cardiovascular adaptation of the fetus after connection to an artificial placenta (AP) in a sheep model, using ultrasound and invasive and non-invasive hemodynamic assessment.

METHODS: This was an experimental study of 12 fetal sheep that were transferred to an AP system, consisting of a pumpless circuit with umbilical cord connection, at 109-117 days' gestation. The study was designed to collect in-utero and postcannulation measurements in all the animals. The first six consecutive fetuses were fitted with intravascular catheters and perivascular probes to obtain invasive physiological data, including arterial and venous intravascular pressures and perivascular blood flows, with measurements taken in utero and at 5 and 30 min after cannulation. These experiments were designed with a survival goal of 1-3 h. The second set of six fetuses were not fitted with catheters, and experiments were aimed at 3-24 h of survival. Echocardiographic assessment of cardiac anatomy and function, as well as measurements of blood flow and pre- and postmembrane pressures recorded by circuit sensors in the AP system, were available for most of the fetuses. These data were acquired in utero and at 30 and 180 min after cannulation.

RESULTS: Compared with in-utero conditions, the pulsatility index at 30 and 180 min after connection to the AP system was reduced in the umbilical artery (median, 1.36 (interquartile range (IQR), 1.06-1.50) vs 0.38 (IQR, 0.31-0.50) vs 0.36 (IQR, 0.29-0.41); P < 0.001 for extreme timepoints) and the ductus venosus (median, 0.50 (IQR, 0.41-0.67) vs 0.29 (IQR, 0.22-0.33) vs 0.36 (IQR, 0.22-0.41); P = 0.011 for extreme timepoints), whereas umbilical venous peak velocity increased (median, 20 cm/s (IQR, 18-22 cm/s) vs 39 cm/s (IQR, 31-43 cm/s) vs 43 cm/s (IQR, 34-54 cm/s); P < 0.001 for extreme timepoints) and flow became more pulsatile. Intravascular monitoring showed that arterial and venous pressures increased transiently after connection, with median values for mean arterial pressure at baseline, 5 min and 30 min of 43 mmHg (IQR, 35-54 mmHg), 72 mmHg (IQR, 61-77 mmHg) and 58 mmHg (IQR, 50-64 mmHg), respectively (P = 0.02 for baseline vs 5 min). Echocardiography showed a similar transient elevation of fetal heart rate at 30 and 180 min after connection compared with in utero (median, 145 bpm (IQR, 142-156 bpm) vs 188 bpm (IQR, 171-209 bpm) vs 175 bpm (IQR, 165-190 bpm); P = 0.001 for extreme timepoints). Fetal cardiac structure and function were mainly preserved; median values for right fractional area change were 36% (IQR, 34-41%) in utero, 38% (IQR, 30-40%) at 30 min and 37% (IQR, 33-40%) at 180 min (P = 0.807 for extreme timepoints).

CONCLUSIONS: Connection to an AP system resulted in a transient fetal hemodynamic response that tended to normalize over hours. In this short-term evaluation, cardiac structure and function were preserved. However, the system resulted in non-physiologically elevated venous pressure and pulsatile flow, which should be corrected to avoid later impairment of cardiac function. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.