评估两种3D T1加权采集(一种覆盖脑,一种覆盖脑与脊髓)所获脑部测量指标的等效性
该研究纳入36名健康对照和42例多发性硬化患者,比较传统脑T1加权成像(brain-T1)与覆盖脑和颈髓的3D T1加权成像(cns-T1)所获脑部及脊髓测量指标的一致性。结果显示,两种采集的皮层厚度、区域体积和脑体积年变化率ICC较高,脊髓面积ICC在健康对照为0.68、在多发性硬化患者为0.92,提示cns-T1可能可替代brain-T1。
要点
- cns-T1与brain-T1所测皮层厚度ICC在健康对照94%区域、多发性硬化患者80%区域大于0.75。
- 区域体积ICC大于0.88,脑体积年变化率ICC大于0.79,两种采集高度一致。
- 脊髓面积ICC在健康对照为0.68、在多发性硬化患者为0.92。
核心结论
- 从3D cns-T1获得的脑部测量与从brain-T1获得的测量高度等效,提示以cns-T1替代brain-T1可能是可行的。
研究设计与样本
- 研究纳入36名健康对照和42例多发性硬化患者,其中18名健康对照和35例多发性硬化患者有基线和1年随访的3T磁共振数据,每个时间点均采集brain-T1和cns-T1两种3D T1加权图像,采用FastSurfer测定区域皮层厚度和体积,SIENA计算每年脑体积变化百分比,Spinal Cord Toolbox估计脊髓面积,以组内相关系数(ICC)评估一致性。
诊断标准与关键数值
- 皮层厚度测量ICC大于0.75的区域比例:健康对照为94%,多发性硬化患者为80%。
- 区域体积ICC大于0.88,脑体积年变化率ICC大于0.79,两组均如此。
- 脊髓面积测量ICC:健康对照为0.68,多发性硬化患者为0.92。
临床应用与阅片要点
- 作者认为以cns-T1替代brain-T1可能是可行的,但未给出具体操作推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: In MS, it is common to acquire brain and spinal cord MR imaging sequences separately to assess the extent of the disease. The goal of this study was to see how replacing the traditional brain T1-weighted images (brain-T1) with an acquisition that included both the brain and the cervical spinal cord (cns-T1) affected brain- and spinal cord-derived measures.
MATERIALS AND METHODS: Thirty-six healthy controls (HC) and 42 patients with MS were included. Of those, 18 HC and 35 patients with MS had baseline and follow-up at 1 year acquired on a 3T magnet. Two 3D T1-weighted images (brain-T1 and cns-T1) were acquired at each time point. Regional cortical thickness and volumes were determined with FastSurfer, and the percentage brain volume change per year was obtained with SIENA. The spinal cord area was estimated with the Spinal Cord Toolbox. Intraclass correlation coefficients (ICC) were calculated to check for consistency of measures obtained from brain-T1 and cns-T1.
RESULTS: Cortical thickness measures showed an ICC >0.75 in 94% of regions in healthy controls and 80% in patients with MS. Estimated regional volumes had an ICC >0.88, and the percentage brain volume change had an ICC >0.79 for both groups. The spinal cord area measures had an ICC of 0.68 in healthy controls and 0.92 in patients with MS.
CONCLUSIONS: Brain measurements obtained from 3D cns-T1 are highly equivalent to those obtained from a brain-T1, suggesting that it could be feasible to replace the brain-T1 with cns-T1.
引用
- Pareto D, Corral JF, Garcia-Vidal A, et al. Assessing the Equivalence of Brain-Derived Measures from Two 3D T1-Weighted Acquisitions: One Covering the Brain and One Covering the Brain and Spinal Cord. AJNR Am J Neuroradiol. 2023. PMID: 37080719. doi:10.3174/ajnr.A7843
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。