文献速递头颈技术与安全CT

基于高千电子伏单能成像与迭代金属伪影抑制重建减少光子计数探测器CT数据集中的牙科材料伪影——能否结合两者优势?

Artifact Reduction From Dental Material in Photon-Counting Detector Computed Tomography Data Sets Based on High-keV Monoenergetic Imaging and Iterative Metal Artifact Reduction Reconstructions-Can We Combine the Best of Two Worlds?
PubMed 文献 · Invest Radiol · 2023-01-01

研究纳入50例有牙科材料且接受颈部临床CT的患者,比较不同虚拟单能成像(VMI)水平(40-190 keV)、标准与锐利卷积核及是否使用迭代金属伪影抑制(IMAR)对牙科材料伪影的减少效果;结果显示IMAR重建伪影减少最显著(最大减少84%,AIX最大减少90%),VMI>70 keV仅在使用IMAR时显著减少伪影(最大减少25%),锐利核较标准核噪声更高。

要点

  • IMAR重建可大幅减少牙科材料金属伪影,伪影指数AIX最大降低90%。
  • VMI>70 keV仅在使用IMAR时显著减少伪影(最大减少25%),单独提高keV效果轻微。
  • 锐利核较标准核图像噪声更高,AIX值更大,IMAR序列中更明显(最大增加38%)。

核心结论

  • 大量牙科材料所致金属伪影可通过IMAR大幅减少,与卷积核选择或VMI设置无关;提高VMI的keV水平仅轻微减少牙科伪影,但该效应与IMAR的获益相加。

研究设计与样本

  • 纳入50例有牙科材料且接受颈部临床CT的患者,使用光子计数探测器CT,重建标准与锐利卷积核、有无IMAR(Qr40、Qr40 IMAR、Qr60、Qr60 IMAR)及不同VMI水平(40-190 keV)的图像系列,在有无牙科伪影的代表性层面相同位置测量CT值的均值与标准差,计算CT值平均绝对误差和伪影指数AIX,采用Wilcoxon检验分析非参数数据。

诊断标准与关键数值

  • VMI水平>70 keV时伪影指标下降,但仅在使用IMAR的重建中差异显著,最大减少25%。
  • 锐利核较标准核图像噪声更高,反映为AIX值更高,且在IMAR序列中更明显,最大增加38%。
  • IMAR重建的伪影减少最显著:CT值平均绝对误差最大减少84%,AIX最大减少90%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The aim of this study was to compare the effectiveness of common strategies for artifact reduction of dental material in photon-counting detector computed tomography data sets.

MATERIALS AND METHODS: Patients with dental material who underwent clinically indicated CT of the neck were enrolled. Image series were reconstructed using a standard and sharp kernel, with and without iterative metal artifact reduction (IMAR) (Qr40, Qr40 IMAR , Qr60, Qr60 IMAR ) at different virtual monoenergetic imaging (VMI) levels (40-190 keV). On representative slice positions with and without dental artifacts, mean and standard deviation of CT values were measured in all series at identical locations. The mean absolute error of CT values ( ) and the artifact index (AIX) were calculated and analyzed focusing on 3 main comparisons: ( a ) different VMI levels versus 70 keV, ( b ) standard versus sharp kernel, and ( c ) nonuse or use of IMAR reconstruction. The Wilcoxon test was used to assess differences for nonparametric data.

RESULTS: The final cohort comprised 50 patients. Artifact measures decreased for VMI levels >70 keV, yet only significantly so for reconstructions using IMAR (maximum reduction, 25%). The higher image noise of the sharp versus standard kernel is reflected in higher AIX values and is more pronounced in IMAR series (maximum increase, 38%). The most profound artifact reduction was observed for IMAR reconstructions (maximum reduction : 84%; AIX: 90%).

CONCLUSIONS: Metal artifacts caused by large amounts of dental material can be substantially reduced by IMAR, regardless of kernel choice or VMI settings. Increasing the keV level of VMI series, on the other hand, only slightly reduces dental artifacts; this effect, however, is additive to the benefit conferred by IMAR reconstructions.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Risch F, Decker JA, Popp D, et al. Artifact Reduction From Dental Material in Photon-Counting Detector Computed Tomography Data Sets Based on High-keV Monoenergetic Imaging and Iterative Metal Artifact Reduction Reconstructions-Can We Combine the Best of Two Worlds? Invest Radiol. 2023. PMID: 36897803. doi:10.1097/RLI.0000000000000967

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。