胼胝体参考范围:生物测量图表构建方法及所获测量值的系统评价

Corpus callosal reference ranges: systematic review of methodology of biometric chart construction and measurements obtained.
PubMed 文献 · Ultrasound Obstet Gynecol · 2023-01-01

该系统评价纳入12项在正常胎儿人群中构建超声或磁共振胼胝体大小图表的观察性研究,按预设方法学标准评分,质量分范围为17.4%至95.7%。研究显示各研究间方法与最终生物测量值存在显著异质性,仅在17%的研究中样本基于人群且连续或随机招募并说明样本量依据。

要点

  • 仅17%的研究为基于人群且连续或随机招募并说明样本量依据,样本选择偏倚风险最大。
  • 仅17%的研究对每个胎儿每次扫描进行超过一次胼胝体生物测量。
  • 仅8%的研究清楚报告了研究人群人口学特征的最低数据集。

核心结论

  • 评价的研究间胼胝体测量方法与最终生物测量值存在显著异质性。
  • 需采用最高质量的统一方法学来定义「短」胼胝体并为父母咨询提供依据。

研究设计与样本

  • 系统评价纳入以在正常胎儿人群中创建超声或磁共振胼胝体大小图表为主要目的的观察性研究。
  • 共12项研究符合纳入标准,按预设的独立商定方法学标准评分并给出总体质量分。

诊断标准与关键数值

  • 各研究质量分范围为17.4%至95.7%。
  • 仅17%的研究为基于人群且连续或随机招募并说明样本量依据。
  • 仅17%的研究对每个胎儿每次扫描进行超过一次胼胝体生物测量。
  • 仅8%的研究清楚报告了研究人群人口学特征的最低数据集。

局限性

  • 评价的研究间胼胝体测量方法与最终生物测量值存在显著异质性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Adequate reference ranges of size of the corpus callosum (CC) are necessary to improve characterization of CC abnormalities and parental counseling. The objective of this study was to evaluate the methodology used in studies developing references charts for CC biometry.

METHODS: We conducted a systematic review of studies on fetal CC biometry using a set of predefined quality criteria of study design, statistical analysis and reporting methods. We included observational studies whose primary aim was to create ultrasound or magnetic resonance imaging charts for CC size in a normal population of fetuses. Studies were scored against a predefined set of independently agreed methodological criteria, and an overall quality score was given for each study.

RESULTS: Twelve studies met the inclusion criteria. Quality scores ranged between 17.4% and 95.7%. The greatest potential for bias was noted for the following items: sample selection and sample-size calculation, as only 17% of the studies were population-based and had consecutive or random recruitment of patients and with a justification of the sample size; number of measurements obtained for CC biometry, as only 17% of the studies performed more than one measurement per fetus and per scan; and description of characteristics of the study population, as only 8% of the studies clearly reported a minimum dataset of demographic characteristics.

CONCLUSIONS: Our review demonstrates substantial heterogeneity in methods and final biometric values of the fetal CC across the evaluated studies. The use of uniform methodology of the highest quality is essential in order to define a 'short' CC and provide appropriate parental counseling. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.