双能CT血管成像在急性非静脉曲张性消化道出血评估中的效用:与数字减影血管造影的比较
研究纳入111例急性非静脉曲张性消化道出血患者,均行双能CT血管成像(DECTA)和数字减影血管造影(DSA),以DSA为金标准比较诊断效能。结果显示虚拟单能图像(60 keV和70 keV)分别改善了图像质量和对比度,但虚拟单能图像数据集与线性融合图像相比未提高诊断准确率,DECTA在此类出血中的诊断效用仍不确定。
要点
- 线性融合图像检出血管病变:读者1为88例(79.3%),读者2为87例(78.4%),DSA显示病变92例(82.9%)。
- 70 keV虚拟单能图像上动脉、血管病变及供血动脉的CNR和SNR显著高于融合图像和其他虚拟单能图像(p<0.005)。
- 两位读者对60 keV图像的主观图像质量评分更高,但差异无统计学意义(p=0.3)。
核心结论
- 在急性非静脉曲张性消化道出血评估中,60 keV和70 keV虚拟单能图像分别改善了图像质量和对比度,但虚拟单能图像数据集与线性融合图像相比未提高诊断准确率,因此DECTA在此类出血中的诊断效用仍不确定。
研究设计与样本
- 研究纳入2016年1月至2021年9月间同时接受DECTA和DSA的111例急性非静脉曲张性消化道出血患者(平均年龄39.2岁,94例男性),以DSA为金标准;由两名对DSA信息不知情的读者独立评估动脉期40至70 keV(每10 keV递增)虚拟单能图像及120kVp等效融合图像。
诊断标准与关键数值
- DECTA线性融合图像检出血管病变:读者1为88例(79.3%),读者2为87例(78.4%),DSA显示病变92例(82.9%);虚拟单能图像与线性融合图像对病变检出的敏感度和特异度无显著差异;70 keV图像上动脉、血管病变及供血动脉的CNR和SNR显著高于融合图像和其他虚拟单能图像(p<0.005);60 keV图像主观图像质量评分更高但差异无统计学意义(p=0.3)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文结论指出DECTA在急性非静脉曲张性消化道出血中的诊断效用仍不确定。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the utility of dual energy CT angiography (DECTA) in acute non-variceal gastrointestinal hemorrhage (ANVGIH) compared to digital subtraction angiography (DSA) as gold standard.
MATERIALS AND METHODS: 111 Patients (mean age: 39.2 years; 94 males) of ANVGIH who underwent both DECTA and DSA between January 2016 and September 2021 were included. Virtual monochromatic (VM) images at 10 keV increments from 40 to 70 keV and blended (120kVp equivalent) images of arterial phase of DECTA were evaluated independently by two readers blinded to DSA information. Quantitative analysis included measurement of attenuation in the major arteries (abdominal aorta, celiac artery, superior mesenteric artery), suspected vascular lesion, and lesion feeding artery to calculate contrast-to-noise ratios (CNRs) and signal-to-noise ratios (SNRs). Qualitative analysis assessed the image quality of each data set using a 3-point Likert scale. Findings on DSA were evaluated by a third reader and both DECTA and DSA were compared.
RESULTS: On linear blended images, vascular lesion was identified by reader 1 in 88 (79.3%) and by reader 2 in 87 (78.4%) patients and DSA showed lesion in 92 (82.9%) patients. The sensitivity and specificity of blended images and VM images of DECTA for lesion detection were not significantly different from each other. The CNR and SNR of arteries, vascular lesion and feeding artery were significantly higher at 70 keV (p < 0.005) compared to blended and other VM images. Although subjective scores for image quality were higher for 60 keV images by both readers, the difference was not statistically significant (p = 0.3). The interobserver agreement was mostly good.
CONCLUSION: In the assessment of ANVGIH, the 60 keV and 70 keV VM images improved the image quality and contrast, respectively, but there was no increase in diagnostic accuracy of VM image datasets compared to linearly blended images. Hence, the diagnostic utility of DECTA in ANVGIH is still uncertain.
引用
- Agarwal A, Kumar KP, Madhusudhan KS, et al. Utility of dual energy CT angiography in the evaluation of acute non-variceal gastrointestinal hemorrhage: comparison with digital subtraction angiography. Abdom Radiol (NY). 2023. PMID: 36939912. doi:10.1007/s00261-023-03864-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。