文献速递心血管MRPETCTDSA

二线心肌灌注成像检测梗阻性狭窄:CMR与PET的头对头比较

Second-Line Myocardial Perfusion Imaging to Detect Obstructive Stenosis: Head-to-Head Comparison of CMR and PET.
PubMed 文献 · JACC Cardiovasc Imaging · 2023-02-08

在冠状动脉CTA疑诊梗阻性狭窄的患者中,头对头比较3.0-T心脏磁共振与82铷PET心肌灌注成像的诊断效能,以有创冠状动脉造影联合血流储备分数为参考标准。372例完成全部检查,CMR与RbPET敏感度相似(59% vs 64%,P=0.21),特异度均较高(84% vs 89%,P=0.08),RbPET总体准确率更高(73% vs 78%,P=0.03)。

要点

  • 冠脉CTA疑诊梗阻性狭窄后,CMR与RbPET敏感度中等且相似,特异度均较高。
  • 以ICA联合FFR为参考,RbPET总体准确率高于CMR(73% vs 78%,P=0.03)。
  • 该患者群体中先进MPI与有创测量常不一致,诊断存在挑战。

核心结论

  • 在冠状动脉CTA疑诊梗阻性狭窄的患者中,与ICA联合FFR相比,CMR与RbPET敏感度相似且中等,特异度均较高;RbPET总体准确率高于CMR。

研究设计与样本

  • Dan-NICAD 2研究,连续纳入1732例因疑诊梗阻性CAD症状转诊行冠状动脉CTA的患者(平均年龄59.1±9.5岁,57.2%为男性)。

诊断标准与关键数值

  • 梗阻性CAD定义为FFR≤0.80或视觉评估直径狭窄>90%;CMR敏感度59%(95%CI:51%-67%)、特异度84%(95%CI:78%-89%);RbPET敏感度64%(95%CI:56%-71%)、特异度89%(95%CI:84%-93%)。

临床应用与阅片要点

  • 冠状动脉CTA疑诊梗阻性狭窄的患者中,445例疑诊狭窄者转诊行CMR与RbPET并随后行ICA,其中372例完成全部检查,164/372(44.1%)检出血液动力学梗阻性CAD。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Guidelines recommend verification of myocardial ischemia by selective second-line myocardial perfusion imaging (MPI) following a coronary computed tomography angiography (CTA) with suspected obstructive coronary artery disease (CAD). Head-to-head data on the diagnostic performance of different MPI modalities in this setting are sparse.

OBJECTIVES: The authors sought to compare, head-to-head, the diagnostic performance of selective MPI by 3.0-T cardiac magnetic resonance (CMR) and 82rubidium positron emission tomography (RbPET) in patients with suspected obstructive stenosis at coronary CTA using invasive coronary angiography (ICA) with fractional flow reserve (FFR) as reference.

METHODS: Consecutive patients (n = 1,732, mean age: 59.1 ± 9.5 years, 57.2% men) referred for coronary CTA with symptoms suggestive of obstructive CAD were included. Patients with suspected stenosis were referred for both CMR and RbPET and subsequently ICA. Obstructive CAD was defined as FFR ≤0.80 or >90% diameter stenosis by visual assessment.

RESULTS: In total, 445 patients had suspected stenosis on coronary CTA. Of these, 372 patients completed both CMR, RbPET and subsequent ICA with FFR. Hemodynamically obstructive CAD was identified in 164 of 372 (44.1%) patients. Sensitivities for CMR and RbPET were 59% (95% CI: 51%-67%) and 64% (95% CI: 56%-71%); P = 0.21, respectively, and specificities 84% (95% CI: 78%-89%) and 89% (95% CI: 84%-93%]); P = 0.08, respectively. Overall accuracy was higher for RbPET compared with CMR (73% vs 78%; P = 0.03).

CONCLUSIONS: In patients with suspected obstructive stenosis at coronary CTA, CMR, and RbPET show similar and moderate sensitivities but high specificities compared with ICA with FFR. This patient group represents a diagnostic challenge with frequent mismatch between advanced MPI tests and invasive measurements. (Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease 2 [Dan-NICAD 2]; NCT03481712).

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Rasmussen LD, Winther S, Eftekhari A, et al. Second-Line Myocardial Perfusion Imaging to Detect Obstructive Stenosis: Head-to-Head Comparison of CMR and PET. JACC Cardiovasc Imaging. 2023. PMID: 36881421. doi:10.1016/j.jcmg.2022.11.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。