文献速递妇产影像儿科影像神经US

早孕期脉络丛与侧脑室比例失调及后续脑室增大的预测

First-trimester choroid-plexus-to-lateral-ventricle disproportion and prediction of subsequent ventriculomegaly.
PubMed 文献 · Ultrasound Obstet Gynecol · 2023-01-01

本研究为病例对照研究,纳入683例单胎妊娠,其中102例孕16周后诊断孤立性脑室增大,分析早孕期11+0至13+6周经腹超声测量的脉络丛面积与侧脑室面积比(PA/VA)等指标。结果显示PA/VA和PL/VL比值对严重脑室增大预测AUC分别为0.90和0.87,对轻度脑室增大AUC分别为0.84和0.82,校准良好,作者认为有前景但需前瞻性研究验证。

要点

  • 早孕期PA/VA比值预测严重脑室增大AUC为0.90,PL/VL为0.87。
  • PA/VA比值预测轻度脑室增大AUC最高,为0.84。
  • 所有脉络丛与侧脑室/头比值在病例组均低于对照组,差异有统计学意义。

核心结论

  • 早孕期应用胎儿脉络丛与侧脑室/头比值预测脑室增大似乎有前景,未来需前瞻性研究验证其作为筛查工具的预测准确性。

研究设计与样本

  • 病例对照研究,纳入683例单胎妊娠,其中102例孕16周后诊断孤立性脑室增大,对照组为无脑室增大的正常胎儿;排除非整倍体、遗传综合征和/或其他脑异常;对储存的早孕期二维超声图像进行盲法离线分析,于11+0至13+6周测量胎儿头围生物参数;另在20例正常胎儿中评估测量者内和测量者间一致性。

诊断标准与关键数值

  • 病例组中轻度脑室增大86例(84.3%),重度16例(15.7%);PA/VA比值预测重度脑室增大AUC为0.90(95%CI 0.82-0.98),PL/VL比值AUC为0.87(95%CI 0.73-0.98),PA/BPD比值AUC为0.73(95%CI 0.54-0.90),PD/VD比值AUC为0.65(95%CI 0.47-0.84);PA/VA比值预测轻度脑室增大AUC为0.84(95%CI 0.79-0.89),PL/VL比值AUC为0.82(95%CI 0.76-0.88),PA/BPD比值AUC为0.76(95%CI 0.69-0.82),PD/VD比值AUC为0.75(95%CI 0.67-0.81);校准曲线显示PA/VA和PL/VL比值校准良好。

临床应用与阅片要点

  • 作者认为早孕期脉络丛与侧脑室/头比值预测脑室增大似乎有前景,未来需前瞻性研究验证其作为筛查工具的预测准确性。

局限性

  • 未来需前瞻性研究验证这些超声标志物作为脑室增大筛查工具的预测准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Ventriculomegaly can be associated with long-term neurodevelopmental impairment. Prenatal diagnosis of ventriculomegaly is most commonly made at the routine second-trimester anomaly scan. The value of first-trimester ultrasound has expanded to early diagnosis and screening of fetal abnormalities. The objective of this study was to assess the predictive accuracy of first-trimester choroid-plexus-to-lateral-ventricle-or-head ratios for development of ventriculomegaly at a later gestational age.

METHODS: This was a case-control study of fetuses with isolated ventriculomegaly diagnosed after 16 weeks' gestation and a control group of normal fetuses (without ventriculomegaly). The exclusion criteria included aneuploidy, genetic syndrome and/or other brain abnormality. Stored two-dimensional first-trimester ultrasound images were analyzed blindly offline and fetal biometry was performed in the axial view of the fetal head. The ratios of choroid plexus area (PA) to lateral ventricular area (VA), choroid plexus length (PL) to lateral ventricular length (VL), choroid plexus diameter (PD) to lateral ventricular diameter (VD) and PA to biparietal diameter (BPD) were measured at 11 + 0 to 13 + 6 weeks' gestation. Intra- and interobserver variability of measurement of these fetal head biometric parameters at 11 + 0 to 13 + 6 weeks' gestation were assessed in 20 normal fetuses using intraclass correlation coefficients with 95% CI. The accuracy of first-trimester biometric measurements for prediction of ventriculomegaly was assessed using the area under the receiver-operating-characteristics curves (AUC).

RESULTS: The analysis included 683 singleton pregnancies, of which 102 fetuses were diagnosed with ventriculomegaly. Ventriculomegaly was mild in 86 (84.3%) cases and severe in the other 16 (15.7%). All first-trimester fetal choroid-plexus-to-lateral-ventricle/head ratios were significantly lower in cases with ventriculomegaly compared with controls (P < 0.001), with good inter- and intraobserver agreement (≥ 0.95) for the majority of the fetal head biometric parameters assessed. On adjusting for crown-rump length, optimism-adjusted AUC values obtained after cross-validation showed that both PL/VL ratio (AUC, 0.87 (95% CI, 0.73-0.98)) and PA/VA ratio (AUC, 0.90 (95% CI, 0.82-0.98)) had good predictive accuracy for severe ventriculomegaly. The PA/BPD ratio (AUC, 0.73 (95% CI, 0.54-0.90)) had modest predictive ability, which was significantly lower compared with that of the PA/VA ratio and PL/VL ratio (P = 0.003 and P = 0.001, respectively). The predictive accuracy of PD/VD ratio was low with an AUC of 0.65 (95% CI, 0.47-0.84). Optimism-adjusted AUC values obtained after cross-validation showed that PA/VA ratio offered the highest predictive accuracy for mild ventriculomegaly with an AUC of 0.84 (95% CI, 0.79-0.89), followed by PL/VL ratio (AUC, 0.82 (95% CI, 0.76-0.88)), PA/BPD ratio (AUC, 0.76 (95% CI, 0.69-0.82)) and PD/VD ratio (AUC, 0.75 (95% CI, 0.67-0.81)). Calibration plots showed that both PA/VA and PL/VL ratios had good calibration.

CONCLUSION: First-trimester prediction of ventriculomegaly using ratios of fetal choroid plexus to lateral ventricle/head appears promising. Future prospective studies are needed to validate the predictive accuracy of these ultrasound markers as a screening tool for ventriculomegaly. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Prasad S, Di Fabrizio C, Eltaweel N, et al. First-trimester choroid-plexus-to-lateral-ventricle disproportion and prediction of subsequent ventriculomegaly. Ultrasound Obstet Gynecol. 2023. PMID: 36864532. doi:10.1002/uog.26189

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。