胎儿脊髓扩散张量成像的可行性及孕龄相关变化
这项前瞻性研究在18至36周孕龄的正常胎儿中评估了脊髓扩散张量成像的可行性,使用1.5T磁共振扫描仪采集矢状扩散加权图像,发现所有完成采集的病例均可提取扩散张量成像参数,且孕龄与全段及各节段脊髓的部分各向异性值呈正相关,而表观扩散系数与孕龄无相关性。
要点
- 在18至36周正常胎儿中,脊髓扩散张量成像采集可行。
- 孕龄与全段脊髓部分各向异性值呈正相关(r=0.37,P<0.01)。
- 孕龄与全段脊髓表观扩散系数无相关性(r=0.01,P=0.99)。
核心结论
- 正常胎儿脊髓扩散张量成像在典型临床实践中可行,并能提取脊髓扩散张量成像参数;妊娠期间胎儿脊髓部分各向异性值存在显著的孕龄相关变化,可能源于宫内髓鞘化过程中水含量下降;本研究可为胎儿扩散张量成像的进一步研究奠定基础。
研究设计与样本
- 前瞻性研究,于2021年12月至2022年6月在法国巴黎Necker-Enfants Malades医院LUMIERE平台进行,为LUMIERE SUR LE FETUS试验的一部分;纳入孕龄18至36周且无胎儿或母体异常的孕妇;使用1.5特斯拉磁共振扫描仪采集胎儿脊柱矢状扩散加权图像,无需镇静;共纳入42名孕妇。
诊断标准与关键数值
- 扩散张量成像参数包括部分各向异性值和表观扩散系数,在脊髓颈段、上胸段、下胸段和腰段提取;孕龄与全段脊髓平均部分各向异性值呈正相关(r=0.37,P<0.01),与颈段(r=0.519,P<0.01)、上胸段(r=0.468,P<0.01)、下胸段(r=0.425,P=0.02)和腰段(r=0.427,P=0.02)部分各向异性值亦呈正相关;孕龄与全段脊髓平均表观扩散系数无相关性(r=0.01,P=0.99),与颈段(r=-0.109,P=0.56)、上胸段(r=-0.226,P=0.22)、下胸段(r=-0.052,P=0.78)和腰段(r=-0.11,P=0.95)表观扩散系数亦无相关性。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 5例(11.9%)患者因胎儿运动未纳入分析。
- 2例(4.8%)患者因纤维束成像重建异常被排除分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Diffusion tensor imaging (DTI) of the fetal brain is a relatively new technique that allows evaluation of white matter tracts of the central nervous system throughout pregnancy, as well as in certain pathological conditions. The objectives of this study were to evaluate the feasibility of DTI of the spinal cord in utero and to examine gestational-age (GA)-related changes in DTI parameters during pregnancy.
METHODS: This was a prospective study conducted between December 2021 and June 2022 in the LUMIERE Platform, Necker-Enfants Malades Hospital, Paris, France, as part of the LUMIERE SUR LE FETUS trial. Women with a pregnancy between 18 and 36 weeks of gestation without fetal or maternal abnormality were eligible for inclusion. Sagittal diffusion-weighted scans of the fetal spine were acquired, without sedation, using a 1.5-Tesla magnetic resonance imaging scanner. The imaging parameters were as follows: 15 non-collinear direction diffusion-weighted magnetic-pulsed gradients with a b-value 700 s/mm2 and one B0 image without diffusion-weighting; slice thickness, 3 mm; field of view (FOV), 36 mm; phase FOV, 1.00; voxel size, 4.5 × 2.8 × 3 mm3 ; number of slices, 7-10; repetition time, 2800 ms; echo time, minimum; and total acquisition time, 2.3 min. DTI parameters, including fractional anisotropy (FA) and apparent diffusion coefficient (ADC), were extracted at the cervical, upper thoracic, lower thoracic and lumbar levels of the spinal cord. Cases with motion degradation and those with aberrant reconstruction of the spinal cord on tractography were excluded. Pearson's correlation analysis was performed to evaluate GA-related changes of DTI parameters during pregnancy.
RESULTS: During the study period, 42 pregnant women were included at a median GA of 29.3 (range, 22.0-35.7) weeks. Five (11.9%) patients were not included in the analysis because of fetal movement. Two (4.8%) patients with aberrant tractography reconstruction were also excluded from analysis. Acquisition of DTI parameters was feasible in all remaining cases (35/35). Increasing GA correlated with increasing FA averaged over the entire fetal spinal cord (r, 0.37; P < 0.01), as well as at the individual cervical (r, 0.519; P < 0.01), upper thoracic (r, 0.468; P < 0.01), lower thoracic (r, 0.425; P = 0.02) and lumbar (r, 0.427; P = 0.02) levels. There was no correlation between GA and ADC averaged over the entire spinal cord (r, 0.01; P = 0.99) or at the individual cervical (r, -0.109; P = 0.56), upper thoracic (r, -0.226; P = 0.22), lower thoracic (r, -0.052; P = 0.78) or lumbar (r, -0.11; P = 0.95) levels.
CONCLUSIONS: This study shows that DTI of the spinal cord is feasible in normal fetuses in typical clinical practice and allows extraction of DTI parameters of the spinal cord. There is a significant GA-related change in FA in the fetal spinal cord during pregnancy, which may result from decreasing water content as observed during myelination of fiber tracts occurring in utero. This study may serve as a basis for further investigation of DTI in the fetus, including research into its potential in pathological conditions that impact spinal cord development. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Corroenne R, Grevent D, Mahallati H, et al. Diffusion tensor imaging of fetal spinal cord: feasibility and gestational-age-related changes. Ultrasound Obstet Gynecol. 2023. PMID: 36971038. doi:10.1002/uog.26208
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。