文献速递腹部MR

深度学习重建的屏气脂肪抑制T2加权成像在肝脏中的应用价值:与常规自由呼吸涡轮自旋回波的比较

Usefulness of Breath-Hold Fat-Suppressed T2-Weighted Images With Deep Learning-Based Reconstruction of the Liver: Comparison to Conventional Free-Breathing Turbo Spin Echo.
PubMed 文献 · Invest Radiol · 2022-12-26

纳入111例疑似肝病患者及58个≥10 mm肝局灶性实性病灶,比较自由呼吸涡轮自旋回波(FB-TSE)、屏气深度学习重建涡轮自旋回波(BH-DL-TSE)与屏气深度学习重建半傅里叶单次激发涡轮自旋回波(BH-DL-HASTE)三种脂肪抑制T2加权成像。BH-DL-TSE采集时间短于FB-TSE,图像质量相当或更优,作者认为可替代FB-TSE;BH-DL-TSE与BH-DL-HASTE各有优势,可互补使用。

要点

  • BH-DL-TSE采集时间40秒,远短于FB-TSE的4分43秒±1分21秒。
  • BH-DL-TSE与FB-TSE在运动相关信号丢失及肝内血管清晰度上显著优于BH-DL-HASTE(P<0.0001)。
  • 三种序列在病灶显示清晰度及病灶-肝脏信号强度比上无显著差异。

核心结论

  • BH-DL-TSE采集时间更短,图像质量与FB-TSE相当或更优,作者认为可在肝脏脂肪抑制T2加权成像中替代FB-TSE;BH-DL-TSE与BH-DL-HASTE各有优势,可互补使用。

研究设计与样本

  • 研究纳入111例疑似肝病患者行3 T磁共振成像,并评估58个≥10 mm的肝局灶性实性病灶,分别采用FB-TSE、原型BH-DL-TSE和原型BH-DL-HASTE采集三组脂肪抑制T2加权图像。

诊断标准与关键数值

  • 由2名放射科医师采用5分法对图像质量进行定性分析,并计算病灶-肝脏信号强度比(LEL-SIR),采用Friedman检验和Dunn多重比较检验评估三种脂肪抑制T2加权成像间的差异。

临床应用与阅片要点

  • 作者认为BH-DL-TSE可替代FB-TSE用于肝脏脂肪抑制T2加权成像;BH-DL-TSE与BH-DL-HASTE各有优势,可互补使用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to evaluate the usefulness of breath-hold turbo spin echo with deep learning-based reconstruction (BH-DL-TSE) in acquiring fat-suppressed T2-weighted images (FS-T2WI) of the liver by comparing this method with conventional free-breathing turbo spin echo (FB-TSE) and breath-hold half Fourier single-shot turbo spin echo with deep learning-based reconstruction (BH-DL-HASTE).

MATERIALS AND METHODS: The study cohort comprised 111 patients with suspected liver disease who underwent 3 T magnetic resonance imaging. Fifty-eight focal solid liver lesions ≥10 mm were also evaluated. Three sets of FS-T2WI were acquired using FB-TSE, prototypical BH-DL-TSE, and prototypical BH-DL-HASTE, respectively. In the qualitative analysis, 2 radiologists evaluated the image quality using a 5-point scale. In the quantitative analysis, we calculated the lesion-to-liver signal intensity ratio (LEL-SIR). Friedman test and Dunn multiple comparison test were performed to assess differences among 3 types of FS-T2WI with respect to image quality and LEL-SIR.

RESULTS: The mean acquisition time was 4 minutes and 43 seconds ± 1 minute and 21 seconds (95% confidence interval, 4 minutes and 28 seconds to 4 minutes and 58 seconds) for FB-TSE, 40 seconds for BH-DL-TSE, and 20 seconds for BH-DL-HASTE. In the qualitative analysis, BH-DL-HASTE resulted in the fewest respiratory motion artifacts ( P < 0.0001). BH-DL-TSE and FB-TSE exhibited significantly less motion-related signal loss and clearer intrahepatic vessels than BH-DL-HASTE ( P < 0.0001). Regarding the edge sharpness of the left lobe, BH-DL-HASTE scored the highest ( P < 0.0001), and BH-DL-TSE scored higher than FB-TSE ( P = 0.0290). There were no significant differences among 3 types of FS-T2WI with respect to the edge sharpness of the right lobe ( P = 0.1290), lesion conspicuity ( P = 0.5292), and LEL-SIR ( P = 0.6026).

CONCLUSIONS: BH-DL-TSE provides a shorter acquisition time and comparable or better image quality than FB-TSE, and could replace FB-TSE in acquiring FS-T2WI of the liver. BH-DL-TSE and BH-DL-HASTE have their own advantages and may be used complementarily.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Ichinohe F, Oyama K, Yamada A, et al. Usefulness of Breath-Hold Fat-Suppressed T2-Weighted Images With Deep Learning-Based Reconstruction of the Liver: Comparison to Conventional Free-Breathing Turbo Spin Echo. Invest Radiol. 2022. PMID: 36728880. doi:10.1097/RLI.0000000000000943

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。