文献速递腹部技术与安全CT

采用深度学习图像重建的74 keV虚拟单能图像评估薄层腹部双能CT:图像质量比较

Evaluation of thin-slice abdominal DECT using deep-learning image reconstruction in 74 keV virtual monoenergetic images: an image quality comparison.
PubMed 文献 · Abdom Radiol (NY) · 2023-02-21

回顾性分析30例门静脉期腹部快速kV切换双能CT(80/140 kVp)扫描,比较0.625 mm与2.5 mm层厚下深度学习图像重建(DLIR)与自适应统计迭代重建(ASIR-V)在74 keV虚拟单能图像中的噪声、CNR、SNR及主观图像质量。DLIR在同层厚下显著降低噪声并提高CNR与SNR(p < 0.001),0.625 mm DLIR较2.5 mm ASIR-V在肝、主动脉和肌肉噪声略高5.5%–16.2%(p < 0.01),脂肪噪声低4.3%(p = 0.08)。结论认为DLIR可促进常规增强腹部双能CT的薄层重建。

要点

  • 同层厚下DLIR较ASIR-V显著降低噪声并提高CNR和SNR(p < 0.001)。
  • 0.625 mm DLIR较2.5 mm ASIR-V在肝、主动脉和肌肉噪声高5.5%–16.2%(p < 0.01)。
  • 0.625 mm DLIR较2.5 mm ASIR-V脂肪噪声低4.3%(p = 0.08)。

核心结论

  • DLIR较ASIR-V显著降低0.625 mm层厚74 keV虚拟单能腹部双能CT图像的噪声、提高CNR和SNR并改善图像质量,可能促进常规增强腹部双能CT的薄层重建。

研究设计与样本

  • 回顾性研究,经机构审查委员会和区域伦理委员会批准,分析30例门静脉期腹部快速kV切换双能CT(80/140 kVp)扫描,重建为74 keV下ASIR-V 60%和DLIR-High、层厚0.625 mm和2.5 mm。

关键影像表现/征象

  • 在肝、主动脉、脂肪组织和肌肉内测量HU和噪声并进行定量评估。
  • 两名委员会认证放射科医生基于五分Likert量表评估图像噪声、锐利度、纹理和整体质量。
  • 定性评估显示DLIR图像质量显著改善,尤其在0.625 mm图像中。

诊断标准与关键数值

  • 定量指标包括噪声、CNR、SNR,在肝、主动脉、脂肪组织和肌肉内测量。
  • 主观图像质量采用五分Likert量表评估噪声、锐利度、纹理和整体质量。
  • 同层厚下DLIR较ASIR-V显著降低噪声并提高CNR和SNR(p < 0.001)。
  • 0.625 mm DLIR较2.5 mm ASIR-V在肝、主动脉和肌肉噪声高5.5%–16.2%(p < 0.01)。
  • 0.625 mm DLIR较2.5 mm ASIR-V脂肪噪声低4.3%(p = 0.08)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare noise, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and image quality using deep-learning image reconstruction (DLIR) vs. adaptive statistical iterative reconstruction (ASIR-V) in 0.625 and 2.5 mm slice thickness gray scale 74 keV virtual monoenergetic (VM) abdominal dual-energy CT (DECT).

METHODS: This retrospective study was approved by the institutional review board and regional ethics committee. We analysed 30 portal-venous phase abdominal fast kV-switching DECT (80/140kVp) scans. Data were reconstructed to ASIR-V 60% and DLIR-High at 74 keV in 0.625 and 2.5 mm slice thickness. Quantitative HU and noise assessment were measured within liver, aorta, adipose tissue and muscle. Two board-certified radiologists evaluated image noise, sharpness, texture and overall quality based on a five-point Likert scale.

RESULTS: DLIR significantly reduced image noise and increased CNR as well as SNR compared to ASIR-V, when slice thickness was maintained (p < 0.001). Slightly higher noise of 5.5-16.2% was measured (p < 0.01) in liver, aorta and muscle tissue at 0.625 mm DLIR compared to 2.5 mm ASIR-V, while noise in adipose tissue was 4.3% lower with 0.625 mm DLIR compared to 2.5 mm ASIR-V (p = 0.08). Qualitative assessments demonstrated significantly improved image quality for DLIR particularly in 0.625 mm images.

CONCLUSIONS: DLIR significantly reduced image noise, increased CNR and SNR and improved image quality in 0.625 mm slice images, when compared to ASIR-V. DLIR may facilitate thinner image slice reconstructions for routine contrast-enhanced abdominal DECT.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。