低水平运动时E/e'比值在诊断射血分数保留的心力衰竭中的效用
研究纳入215例射血分数≥50%的呼吸困难患者行运动负荷超声心动图,评估20W低水平运动时E/e'比值的可行性及诊断价值。E/e'比值可行性从静息100%降至20W运动96.3%、峰值运动74.9%;E/e'20W预测峰值E/e'≤15的AUC为0.91,切值≤12.4特异度94%、阳性预测值98%。在45例行运动右心导管亚组中,E/e'20W预测运动时PCWP正常的AUC为0.77,切值≤12.4特异度83%。
要点
- 20W低水平运动时E/e'比值可行性96.3%,高于峰值运动的74.9%。
- E/e'20W≤12.4预测峰值E/e'≤15特异度94%、阳性预测值98%。
- E/e'20W≤12.4预测运动时PCWP正常特异度83%。
核心结论
- 低水平运动时E/e'比值高度可行,能以高特异度预测峰值运动时E/e'比值或PCWP正常,作者认为E/e'20W可作为峰值运动值的替代用于排除呼吸困难患者的HFpEF。
研究设计与样本
- 在215例EF≥50%的呼吸困难患者中行踏车运动负荷超声心动图,并在45例受试者亚组中行运动右心导管检查。
诊断标准与关键数值
- E/e'20W预测峰值E/e'≤15的AUC为0.91(P<0.0001),切值≤12.4时特异度94%、阳性预测值98%;E/e'20W预测运动时PCWP正常的AUC为0.77(P=0.01),切值≤12.4时特异度83%。
临床应用与阅片要点
- E/e'比值可行性从静息100%降至20W运动96.3%、峰值运动74.9%,下降由E-A融合所致;E/e'峰值>15者E/e'比值从静息11.2±2.1升至20W运动16.3±3.5(P<0.0001),20W运动至峰值运动无显著变化(P=0.12);20W运动时93%的HFpEF患者PCWP≥25 mm Hg。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: E/e' ratio during exercise is the key parameter in identifying elevated pulmonary capillary wedge pressure (PCWP), and thus heart failure with preserved ejection fraction (HFpEF). However, its diagnostic value is limited when mitral inflow or tissue velocities are fused during elevated heart rate.
OBJECTIVES: The authors hypothesized that E/e' ratio during low-level (20 W) exercise (E/e'20W) can help diagnose HFpEF.
METHODS: Ergometric exercise stress echocardiography was performed in 215 dyspneic patients with an EF ≥50%. The authors determined the feasibility of E/e' ratio at each stage (frequency of patients who had measurable E/e' without E-A fusion among 215 participants) and examined whether E/e'20W could predict normal E/e' ratio during peak exercise (E/e'peak ≤15). The authors also evaluated whether E/e'20W could predict normal PCWP during exercise (PCWP <25 mm Hg) in a subset of participants (n = 45) who underwent exercise right heart catheterization.
RESULTS: The feasibility of the E/e' ratio decreased from 100% at rest to 96.3% during 20-W exercise and 74.9% during peak exercise caused by E-A fusion. In patients with E/e'peak >15, there was an increase in E/e' ratio from rest to 20-W exercise (11.2 ± 2.1 to 16.3 ± 3.5; P < 0.0001), but it did not change significantly from 20-W exercise to peak exercise (P = 0.12). E/e'20W predicted E/e'peak ≤15 (AUC: 0.91; P < 0.0001) with the cutoff value of ≤12.4 showing high specificity (94%) and positive predictive value (98%). During 20-W exercise, 93% of the HFpEF patients developed PCWP ≥25 mm Hg. E/e'20W predicted normal PCWP during exercise (AUC: 0.77; P = 0.01) with the cutoff value of ≤12.4 showing high specificity (83%).
CONCLUSIONS: E/e' ratio during low-level exercise is highly feasible and predicts normal E/e' ratio or PCWP during peak exercise with high specificity. These data suggest that E/e'20W could be used as an alternative to the peak exercise value to rule out HFpEF in patients with dyspnea.
引用
- Harada T, Obokata M, Kagami K, et al. Utility of E/e' Ratio During Low-Level Exercise to Diagnose Heart Failure With Preserved Ejection Fraction. JACC Cardiovasc Imaging. 2022. PMID: 36752422. doi:10.1016/j.jcmg.2022.10.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。