博来霉素诱导猪肺纤维化模型的磁共振弹性成像研究

Magnetic Resonance Elastography (MRE) of Bleomycin-Induced Pulmonary Fibrosis in an Animal Model.
PubMed 文献 · Invest Radiol · 2022-10-25

本研究在9只约克夏猪右肺气管内滴注2个剂量的博来霉素诱导肺纤维化,于基线、第4周和第8周用1.5 T磁共振弹性成像测量肺剪切刚度,并同步行支气管肺泡灌洗,末次扫描后取全肺行组织学分析。结果显示损伤右肺与对照左肺剪切刚度比值在基线、第4周和第8周分别为0.98±0.23、1.52±0.41和1.64±0.40,高剂量组支气管肺泡灌洗液蛋白升高并见斑片状浸润、胶原和α-平滑肌肌动蛋白染色增强,低剂量组及高剂量组对照左肺未见显著组织病理学改变。结论认为磁共振弹性成像可用于检测博来霉素攻击后猪肺刚度的变化。

要点

  • 损伤右肺与对照左肺剪切刚度比值在基线、第4周、第8周分别为0.98±0.23、1.52±0.41、1.64±0.40。
  • 对照左肺平均刚度在基线、第4周、第8周分别为1.02±0.27 kPa、0.86±0.29 kPa、0.68±0.20 kPa。
  • 高剂量组支气管肺泡灌洗液蛋白升高,组织学见斑片状浸润、胶原及α-平滑肌肌动蛋白染色增强。

核心结论

  • 磁共振弹性成像可用于检测博来霉素攻击后猪肺刚度的变化。

研究设计与样本

  • 动物实验:9只约克夏猪右肺气管内滴注2个剂量博来霉素诱导肺纤维化,于基线、第4周和第8周在1.5 T磁共振扫描仪上用自旋回波回波平面成像序列行磁共振弹性成像,每次扫描时行支气管肺泡灌洗,末次扫描后取全肺行组织学分析。

关键影像表现/征象

  • 对照左肺平均磁共振弹性成像刚度在基线、第4周、第8周分别为1.02±0.27 kPa、0.86±0.29 kPa、0.68±0.20 kPa。
  • 损伤右肺与对照左肺剪切刚度比值在基线、第4周、第8周分别为0.98±0.23、1.52±0.41、1.64±0.40。
  • 高剂量组支气管肺泡灌洗液蛋白升高,组织学见斑片状浸润、胶原和α-平滑肌肌动蛋白染色增强。
  • 低剂量组及高剂量组对照左肺未见显著组织病理学改变。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Idiopathic pulmonary fibrosis is responsible for 40,000 deaths annually in the United States. A hallmark of idiopathic pulmonary fibrosis is elevated collagen deposition, which alters lung stiffness. Clinically relevant ways to measure changes in lung stiffness during pulmonary fibrosis are not available, and new noninvasive imaging methods are needed to measure changes in lung mechanical properties.

OBJECTIVES: Magnetic resonance elastography (MRE) is an in vivo magnetic resonance imaging technique proven to detect changes in shear stiffness in different organs. This study used MRE, histology, and bronchoalveolar lavage (BAL) to study changes in the mechanical and structural properties of the lungs after bleomycin-induced pulmonary fibrosis in pigs.

MATERIALS AND METHODS: Pulmonary fibrosis was induced in 9 Yorkshire pigs by intratracheal instillation of 2 doses of bleomycin into the right lung only. Magnetic resonance elastography scans were performed at baseline and week 4 and week 8 postsurgery in a 1.5 T magnetic resonance imaging scanner using a spin-echo echo planar imaging sequence to measure changes in lung shear stiffness. At the time of each scan, a BAL was performed. After the final scan, whole lung tissue was removed and analyzed for histological changes.

RESULTS: Mean MRE-derived stiffness measurements at baseline, week 4, and week 8 for the control (left) lungs were 1.02 ± 0.27 kPa, 0.86 ± 0.29 kPa, and 0.68 ± 0.20 kPa, respectively. The ratio of the shear stiffness in the injured (right) lung to the uninjured control (left) lung at baseline, week 4, and week 8 was 0.98 ± 0.23, 1.52 ± 0.41, and 1.64 ± 0.40, respectively. High-dose animals showed increased protein in BAL fluid, elevated inflammation observed by the presence of patchy filtrates, and enhanced collagen and α-smooth muscle actin staining on histological sections. Low-dose animals and the control (left) lungs of high-dose animals did not show significant histopathological changes.

CONCLUSION: This study demonstrated that MRE can be used to detect changes in lung stiffness in pigs after bleomycin challenge.

来源:Invest Radiol,查看原文。版权归原作者所有。