对比增强三维FLAIR序列上的边缘强化模式及MRI特征在区分脑膜瘤与恶性硬脑膜肿瘤中的价值
回顾性纳入102例脑膜瘤与31例恶性硬脑膜肿瘤患者,评估对比增强FLAIR上的边缘强化模式及MRI特征。完整边缘强化(CE-FLAIR边缘征)在脑膜瘤中占89.2%,显著高于恶性硬脑膜肿瘤的6.5%(P < .001),诊断脑膜瘤的敏感度89.2%、特异度93.5%、准确率90.2%。结论认为该征象有助于鉴别,但<2.0 cm或位于海绵窦区的脑膜瘤可无此征象。
要点
- 对比增强FLAIR上肿瘤-脑界面完整边缘强化(CE-FLAIR边缘征)是脑膜瘤的可靠预测征象。
- 该征象诊断脑膜瘤敏感度89.2%、特异度93.5%、准确率90.2%。
- 骨质增生提示脑膜瘤,骨质破坏伴皮质突破及柔脑膜强化提示恶性硬脑膜肿瘤。
核心结论
- 对比增强FLAIR上的完整边缘强化模式是脑膜瘤的可靠预测征象,有助于区分脑膜瘤与恶性硬脑膜肿瘤。
研究设计与样本
- 回顾性研究,纳入102例脑膜瘤和31例恶性硬脑膜肿瘤患者,均行治疗前MR成像。
关键影像表现/征象
- 对比增强FLAIR上肿瘤-脑界面完整边缘强化(CE-FLAIR边缘征)在脑膜瘤中见于91/102(89.2%),在恶性硬脑膜肿瘤中见于2/31(6.5%)。
- 骨质增生是提示脑膜瘤诊断的MR成像特征。
- 骨质破坏伴皮质突破和柔脑膜强化提示恶性硬脑膜肿瘤。
诊断标准与关键数值
- 完整对比增强FLAIR边缘强化诊断脑膜瘤:敏感度89.2%,特异度93.5%,准确率90.2%。
- CE-FLAIR边缘征在脑膜瘤中的出现频率为89.2%(91/102),在恶性硬脑膜肿瘤中为6.5%(2/31),组间比较P < .001。
临床应用与阅片要点
- 阅片时可关注对比增强FLAIR上肿瘤-脑界面是否呈完整边缘强化,完整强化提示脑膜瘤。
- 注意<2.0 cm的脑膜瘤或位于海绵窦区的脑膜瘤可不出现对比增强FLAIR边缘强化。
局限性
- <2.0 cm或位于海绵窦位置的脑膜瘤未显示对比增强FLAIR边缘强化。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Meningiomas are the most common type of extra-axial dural-based tumors; however, malignant dural-based tumors can mimic meningiomas on imaging. The aim of this study was to determine the efficacy of differentiating meningiomas from malignant dural-based tumors by using rim-enhancement patterns on a contrast-enhanced FLAIR sequence and MR imaging characteristics.
MATERIALS AND METHODS: This retrospective study included 102 patients with meningiomas and 31 patients with malignant dural-based tumors who underwent pretreatment MR imaging. The rim-enhancement patterns on contrast-enhanced FLAIR and MR imaging characteristics, including the dural tail sign, hyperostosis, bony destruction, leptomeningeal enhancement, peritumoral edema, T2-weighted signal intensity, and tumor enhancement were evaluated.
RESULTS: Complete rim enhancement of the tumor-brain interface on contrast-enhanced FLAIR (contrast-enhanced-FLAIR rim sign) was present in most meningiomas (91/102, 89.2%) and at significantly greater frequency than in malignant dural-based tumors (2/31, 6.5%) (P < .001). Complete contrast-enhanced FLAIR rim enhancement provided high sensitivity (89.2%), specificity (93.5%), and accuracy (90.2%) for diagnosing meningioma. Additionally, hyperostosis was an MR imaging characteristic that suggested a diagnosis of meningioma. In contrast, bony destruction with cortical breakthrough and leptomeningeal enhancement suggested malignant dural-based tumors. There were limitations of meningiomas of <2.0 cm or at cavernous sinus locations that did not demonstrate contrast-enhanced FLAIR rim enhancement.
CONCLUSIONS: The rim-enhancement pattern on contrast-enhanced FLAIR could help differentiate meningiomas and malignant dural-based tumors. The presence of complete rim enhancement on contrast-enhanced FLAIR was a robust predictive sign for meningioma.
引用
- Panyaping T, Punpichet M, Tunlayadechanont P, et al. Usefulness of a Rim-Enhancing Pattern on the Contrast-Enhanced 3D-FLAIR Sequence and MRI Characteristics for Distinguishing Meningioma and Malignant Dural-Based Tumor. AJNR Am J Neuroradiol. 2023. PMID: 36732030. doi:10.3174/ajnr.A7780