文献速递骨肌MRCT

超短回波时间(UTE)与零回波时间(ZTE)磁共振成像在骨关节炎评估中的临床应用

Clinical application of ultrashort echo time (UTE) and zero echo time (ZTE) magnetic resonance (MR) imaging in the evaluation of osteoarthritis.
PubMed 文献 · Skeletal Radiol · 2023-01-06

本文综述了超短回波时间(UTE)与零回波时间(ZTE)磁共振成像在骨关节炎评估中的应用,重点在膝关节。这些技术可对短T2组织(骨、肌腱、钙化软骨、半月板、韧带)进行定性和定量评估,有助于识别早期退变和亚临床损伤;ZTE可检测骨信号并产生类似CT的组织对比,可能避免评估骨性特征时进行CT检查。

要点

  • UTE磁共振可定性定量评估短T2组织(骨、钙化软骨、半月板),识别早期退变和亚临床损伤。
  • ZTE磁共振可检测骨信号并产生类似CT的组织对比,可能避免评估骨性特征时进行CT检查。
  • 骨关节炎累及多种短T2组织,常规磁共振上呈暗信号,UTE和ZTE可改善显示。

核心结论

  • UTE和ZTE磁共振成像可对短T2组织进行定性和定量评估,有助于识别早期退变和亚临床损伤;ZTE可检测骨信号并产生类似CT的组织对比,可能避免评估骨关节炎骨性特征时进行CT检查。

研究设计与样本

  • 综述,描述UTE和ZTE磁共振成像在肌肉骨骼组织中的应用,重点关注膝关节骨关节炎,并引用文献中的结构和功能参考标准。

关键影像表现/征象

  • 许多与骨关节炎发生和进展相关的肌肉骨骼组织本质为短T2,图像采样开始时信号已衰减至最低而呈暗信号。
  • UTE和ZTE磁共振成像可对短T2组织(骨、肌腱、钙化软骨、半月板、韧带)进行定性和定量评估。
  • ZTE磁共振成像可检测骨信号并产生类似CT的组织对比。

临床应用与阅片要点

  • UTE磁共振成像可用于定性定量评估短T2组织(骨、钙化软骨、半月板),识别早期退变和亚临床损伤。
  • ZTE磁共振成像可检测骨信号并产生类似CT的组织对比,可能避免评估骨关节炎骨性特征时进行CT检查。

局限性

  • UTE和ZTE磁共振成像尚未在临床上广泛开展。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Novel compositional magnetic resonance (MR) imaging techniques have allowed for both the qualitative and quantitative assessments of tissue changes in osteoarthritis, many of which are difficult to characterize on conventional MR imaging. Ultrashort echo time (UTE) and zero echo time (ZTE) MR imaging have not been broadly implemented clinically but have several applications that leverage contrast mechanisms for morphologic evaluation of bone and soft tissue, as well as biochemical assessment in various stages of osteoarthritis progression. Many of the musculoskeletal tissues implicated in the initiation and progression of osteoarthritis are short T2 in nature, appearing dark as signal has already decayed to its minimum when image sampling starts. UTE and ZTE MR imaging allow for the qualitative and quantitative assessments of these short T2 tissues (bone, tendon, calcified cartilage, meniscus, and ligament) with both structural and functional reference standards described in the literature [1-3]. This review will describe applications of UTE and ZTE MR imaging in musculoskeletal tissues focusing on its role in knee osteoarthritis. While the review will address tissue-specific applications of these sequences, it is understood that osteoarthritis is a whole joint process with involvement and interdependence of all tissues. KEY POINTS: • UTE MR imaging allows for the qualitative and quantitative evaluation of short T2 tissues (bone, calcified cartilage, and meniscus), enabling identification of both early degenerative changes and subclinical injuries that may predispose to osteoarthritis. • ZTE MR imaging allows for the detection of signal from bone, which has some of the shortest T2 values, and generates tissue contrast similar to CT, potentially obviating the need for CT in the assessment of osseous features of osteoarthritis.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Cheng KY, Moazamian D, Ma Y, et al. Clinical application of ultrashort echo time (UTE) and zero echo time (ZTE) magnetic resonance (MR) imaging in the evaluation of osteoarthritis. Skeletal Radiol. 2023. PMID: 36607355. doi:10.1007/s00256-022-04269-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。