平衡稳态自由进动序列在机器人辅助MRI引导前列腺穿刺活检中的价值:超越定位扫描
回顾性纳入67例MRI疑诊前列腺癌(PI-RADS 2.1≥3)行MRI引导经直肠穿刺活检的男性,比较T2WI、DWI与平衡稳态自由进动序列(bSSFP)显示病灶的清晰度,bSSFP对病灶的显示优于T2WI、接近DWI,且用bSSFP替代T2WI可缩短活检时间。
要点
- bSSFP对前列腺病灶的显示优于T2WI,清晰可见比例42% vs 27%。
- DWI清晰可见比例最高(82%),bSSFP居中(42%),T2WI最低(27%)。
- bSSFP与T2WI观察者间一致性极好(k=0.94 vs 0.97),DWI为好(k=0.75)。
核心结论
- bSSFP有助于显示前列腺病灶,以bSSFP替代T2WI可缩短MRI引导经直肠穿刺活检的时长。
研究设计与样本
- 回顾性研究,纳入67例MRI上单一可疑癌灶(PI-RADS 2.1≥3)并接受MRI引导经直肠穿刺活检的男性,由两名泌尿放射科医生独立评分。
关键影像表现/征象
- 病灶清晰可见比例:T2WI 27%(18/67),DWI 82%(55/67),bSSFP 42%(28/67)。
- 病灶不可见比例:T2WI 18%(12/67),DWI 5%(3/67),bSSFP 10%(7/67)。
- 病灶轻微可见比例:T2WI 56%(37/67),DWI 13%(9/67),bSSFP 48%(32/67)。
诊断标准与关键数值
- 病灶显示清晰度采用3分制评分:1分为不可见,2分为轻微可见,3分为清晰可见。
- 组织学确诊前列腺癌的病灶轻微至清晰可见比例:T2WI 85%(41/48),DWI 100%(48/48),bSSFP 94%(45/48)。
- PI-RADS≥4的病灶可见比例:T2WI 87%(47/54),DWI 100%(54/54),bSSFP 93%(50/54)。
- Gleason≥3+4的病灶可见比例:T2WI 85%(37/43),DWI 100%(43/43),bSSFP 95%(41/43)。
- 观察者间一致性:T2WI k=0.97,bSSFP k=0.94,DWI k=0.75。
临床应用与阅片要点
- bSSFP可用于MRI引导经直肠穿刺活检中前列腺病灶的显示。
- 作者认为以bSSFP替代T2WI可缩短MRI引导经直肠穿刺活检的时长。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To determine whether bSSFP images are useful for visualizing prostatic lesionsin MRI-guided in-bore transrectal biopsy.
METHODS: This retrospective studyincluded 67 men witha single suspected cancer on MRI (PI-RADS 2.1 category ≥ 3) who underwent in-bore transrectal MRI-guided biopsy. Two uroradiologists independently rated lesion conspicuity on a 3-point scale (1:non-visible, 2:slightly visible, 3:clearly visible) on T2WI, DWI, and balanced SSFP.We used measures of frequency to compare lesion conspicuity in 3 sequences. We used Cohen's kappa to assess inter-rater reliability.
RESULTS: Lesions were rated (1) non-visible in 18 % (12/67) of T2WI, 5 % (3/67) of DWI, and 10 % (7/67) of balanced SSFP images, (2) slightly visible in 56 % (37/67) on T2WI, 13 % (9/67) on DWI, and 48 % (32/67) on bSSFP, and (3) clearly visible in 27 %(18/67) on T2WI, 82 % (55/67) on DWI, and 42 % (28/67) on bSSFP. Lesions classified as prostate cancer at histology were slightly-clearly visible in 85 % (41/48) on T2WI, 100 % (48/48) on DWI, and 94 % (45/48) on bSSFP. Lesions classified as PI-RADS ≥ 4 were visible in 87 % (47/54) of T2WI, 100 % (54/54) of DWI, and 93 % (50/54) of bSSFP. Gleason ≥ 3 + 4 lesions were visible in 85 % (37/43) of T2WI, 100 % (43/43) of DWI, and 95 % (41/43) of bSSFP. Inter-rater agreement was excellent for T2WI (k = 0.97) and bSSFP (k = 0.94), and good for DWI (k = 0.75).
CONCLUSION: Balanced SSFP is useful for visualizing prostatic lesions. Replacing T2WI with balanced SSFP can reduce the duration of in-bore transrectal MRI-guided biopsy.
引用
- Vilanova JC, Pérez de Tudela A, Thio-Henestrosa S, et al. Usefulness of balanced SSFP sequence in robot-assisted MRI-guided prostate biopsy: Beyond scouting. Eur J Radiol. 2023. PMID: 36689791. doi:10.1016/j.ejrad.2023.110707
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。