文献速递心血管CT

基于冠状动脉CT血管成像的冠脉血流动力学能量用于提高血流动力学显著狭窄检出的可行性

Feasibility of CT Angiography-derived Kinetic Energy of Coronary Flow to Improve the Detection of Hemodynamically Significant Coronary Stenosis.
PubMed 文献 · Radiol Cardiothorac Imaging · 2022-12-15

单中心回顾性研究纳入113例冠状动脉CT血管成像示中度狭窄(30%-70%)并接受有创血流储备分数(FFR)检查的患者,计算狭窄区域近端冠脉直径与心肌质量得出的血流动力学能量,并与无网格模拟的模拟FFR(sFFR)比较。144支血管中53支(37%)存在血流动力学显著狭窄(有创FFR≤0.80),显著狭窄血管的血流动力学能量高于非显著狭窄血管(79 mJ/kg vs 36 mJ/kg,P<.001)。在直径狭窄与sFFR基础上加入血流动力学能量,受试者工作特征曲线下面积从0.89提高至0.93(P=.04)。

要点

  • 显著狭窄血管血流动力学能量高于非显著狭窄血管(79 mJ/kg vs 36 mJ/kg,P<.001)。
  • 血流动力学能量每增加20 mJ/kg,显著狭窄风险比值比为1.92(95%CI:1.37,2.95;P<.001)。
  • 在直径狭窄与sFFR基础上加入血流动力学能量,AUC从0.89升至0.93(P=.04)。

核心结论

  • 血流动力学能量在检测有创FFR评估的血流动力学显著狭窄方面较sFFR具有增量价值。

研究设计与样本

  • 单中心回顾性研究纳入113例患者(平均年龄68岁±9[SD],80例男性),于2015年12月至2020年3月期间行冠状动脉CT血管成像示中度狭窄(30%-70%)并随后行有创FFR检查,共评估144支血管。

关键影像表现/征象

  • 血流动力学能量通过狭窄区域近端冠状动脉直径与心肌质量计算。
  • 采用无网格模拟计算sFFR。
  • 以有创FFR≤0.80作为血流动力学显著狭窄的参考标准,144支血管中53支(37%)存在显著狭窄。

诊断标准与关键数值

  • 血流动力学能量:显著狭窄血管79 mJ/kg(IQR,58-104 mJ/kg)vs 非显著狭窄血管36 mJ/kg(IQR,23-59 mJ/kg),P<.001。
  • 多变量分析(纳入直径狭窄与sFFR):血流动力学能量每20 mJ/kg的比值比为1.92(95%CI:1.37,2.95;P<.001)。
  • 以直径狭窄与sFFR为基础,加入血流动力学能量后AUC从0.89(95%CI:0.84,0.95)提高至0.93(95%CI:0.89,0.97)(P=.04)。

临床应用与阅片要点

  • 冠状动脉CT血管成像示中度狭窄(30%-70%)时,血流动力学能量可作为sFFR之外的补充指标。
  • 有创FFR≤0.80定义为血流动力学显著狭窄,与血流动力学能量的诊断参考标准一致。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate whether coronary flow kinetic energy has incremental value over simulated fractional flow reserve (sFFR) in diagnosing hemodynamically significant stenosis assessed with coronary CT angiography and invasive fractional flow reserve (FFR).

MATERIALS AND METHODS: This single-center retrospective study included 113 patients (mean age, 68 years ± 9 [SD]; 80 men) who underwent coronary CT angiography showing intermediate stenosis (30%-70% stenosis) and subsequent invasive FFR between December 2015 and March 2020. Kinetic energy was calculated using proximal coronary diameter and myocardial mass of the stenotic region. A mesh-free simulation was performed to calculate the sFFR. Invasive FFR of 0.80 or less indicated hemodynamically significant stenosis. Models using diameter stenosis, kinetic energy, and sFFR were compared by analyzing the receiver operating characteristic curve.

RESULTS: Of the 144 vessels evaluated, 53 vessels (37%) had hemodynamically significant stenosis. Kinetic energy of vessels with significant stenosis was higher than that of vessels with nonsignificant stenosis (79 mJ/kg [IQR, 58-104 mJ/kg] vs 36 mJ/kg [IQR, 23-59 mJ/kg]; P < .001). Multivariable analysis including diameter stenosis and sFFR showed that kinetic energy (per 20 mJ/kg; odds ratio, 1.92; 95% CI: 1.37, 2.95; P < .001) was a predictor of hemodynamically significant stenosis. Adding kinetic energy to diameter stenosis and sFFR improved the area under the receiver operating characteristic curve from 0.89 (95% CI: 0.84, 0.95) to 0.93 (95% CI: 0.89, 0.97) (P = .04).

CONCLUSION: Kinetic energy had incremental value over sFFR in detecting hemodynamically significant stenosis assessed with invasive FFR.Keywords: Coronary CT Angiography, Coronary Arteries, Fractional Flow Reserve, Kinetic Energy, Cardiac Supplemental material is available for this article © RSNA, 2022.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Tomizawa N, Nozaki Y, Fujimoto S, et al. Feasibility of CT Angiography-derived Kinetic Energy of Coronary Flow to Improve the Detection of Hemodynamically Significant Coronary Stenosis. Radiol Cardiothorac Imaging. 2022. PMID: 36601450. doi:10.1148/ryct.220147

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。