头动加速运动估计与校正技术(SAMER)在住院与急诊环境中三维MR成像的临床评估

Clinical Evaluation of Scout Accelerated Motion Estimation and Reduction Technique for 3D MR Imaging in the Inpatient and Emergency Department Settings.
PubMed 文献 · AJNR Am J Neuroradiol · 2023-01-26

本研究纳入97例在住院和急诊环境中接受脑MR检查的患者,对加速T1加权MPRAGE序列回顾性应用SAMER运动校正,由两名盲法神经放射科医师按5级运动严重程度评分。SAMER重建中位时间1分47秒,整体运动评分显著改善(P<.005),中度运动病例100%改善、重度运动病例75%改善,69%的运动所致不可诊断病例(4级和5级)校正后变为可诊断。

要点

  • SAMER使69%的运动所致不可诊断病例(4级和5级)校正后变为可诊断。
  • 中度运动病例运动评分100%改善,重度运动病例75%改善。
  • 轻微或无运动病例中SAMER对整体运动评分影响可忽略。

核心结论

  • SAMER改善了存在运动伪影的临床脑MR检查的诊断图像质量,改善在中度或重度运动病例中最为明显。

研究设计与样本

  • 回顾性研究纳入97例在住院和急诊环境中接受脑MR检查的患者,对包含平扫和增强的加速T1加权MPRAGE序列回顾性应用SAMER运动校正,由两名盲法神经放射科医师按5级运动严重程度评分(1级=无,2级=轻微,3级=轻度,4级=中度,5级=重度)对校正前后图像进行评分。

关键影像表现/征象

  • 运动伪影减少见于28%的病例,64%的病例无变化,8%的病例增加。
  • 轻微或无运动病例中SAMER对整体运动评分影响可忽略。
  • 轻度、中度、重度运动病例中SAMER分别平均改善运动评分0.3级(SD,0.5)、1.1级(SD,0.3)和1.1级(SD,0.8)。

诊断标准与关键数值

  • 5级运动严重程度评分:1级=无,2级=轻微,3级=轻度,4级=中度,5级=重度。
  • SAMER重建中位时间为1分47秒。
  • SAMER运动校正使所有检查的整体运动评分显著改善(P<.005)。
  • 中度运动病例中SAMER使运动评分改善的比例为100%,重度运动病例中为75%。
  • 运动所致不可诊断病例(4级和5级)中69%经SAMER校正后被认为可诊断。

临床应用与阅片要点

  • SAMER可回顾性应用于加速T1加权MPRAGE序列,用于改善存在运动伪影的临床脑MR检查的图像质量。
  • 对中度或重度运动病例,SAMER的运动评分改善最为明显。
  • 对轻微或无运动病例,SAMER对整体运动评分影响可忽略。
  • 8%的病例运动伪影增加。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: A scout accelerated motion estimation and reduction (SAMER) framework has been developed for efficient retrospective motion correction. The goal of this study was to perform an initial evaluation of SAMER in a series of clinical brain MR imaging examinations.

MATERIALS AND METHODS: Ninety-seven patients who underwent MR imaging in the inpatient and emergency department settings were included in the study. SAMER motion correction was retrospectively applied to an accelerated T1-weighted MPRAGE sequence that was included in brain MR imaging examinations performed with and without contrast. Two blinded neuroradiologists graded images with and without SAMER motion correction on a 5-tier motion severity scale (none = 1, minimal = 2, mild = 3, moderate = 4, severe = 5).

RESULTS: The median SAMER reconstruction time was 1 minute 47 seconds. SAMER motion correction significantly improved overall motion grades across all examinations (P < .005). Motion artifacts were reduced in 28% of cases, unchanged in 64% of cases, and increased in 8% of cases. SAMER improved motion grades in 100% of moderate motion cases and 75% of severe motion cases. Sixty-nine percent of nondiagnostic motion cases (grades 4 and 5) were considered diagnostic after SAMER motion correction. For cases with minimal or no motion, SAMER had negligible impact on the overall motion grade. For cases with mild, moderate, and severe motion, SAMER improved the motion grade by an average of 0.3 (SD, 0.5), 1.1 (SD, 0.3), and 1.1 (SD, 0.8) grades, respectively.

CONCLUSIONS: SAMER improved the diagnostic image quality of clinical brain MR imaging examinations with motion artifacts. The improvement was most pronounced for cases with moderate or severe motion.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。