人工智能用于减少乳腺X线筛查中不必要的召回:一项模拟研究
该模拟阅读研究纳入2016年1月至2019年12月两个筛查中心793例因筛查乳腺X线发现异常而被召回补充摄影的女性,由三名乳腺专科放射科医生在有和无人工智能辅助下序贯判读。人工智能辅助后平均AUC从0.79升至0.89,平均特异度从41.9%升至53.9%,平均召回率从60.4%降至49.5%,平均敏感度无统计学差异。
要点
- AI辅助判读可降低筛查乳腺X线的召回率,并提高诊断AUC和特异度。
- AI辅助后平均敏感度无统计学差异,但经验最少者的敏感度从79.6%升至90.7%。
- 该研究为模拟阅读研究,结论基于因筛查异常被召回补充摄影的女性。
核心结论
- 在该模拟研究中,AI辅助判读减少了召回数量并提高了诊断性能,研究对象为乳腺X线筛查后因发现异常而被召回补充摄影的女性。
研究设计与样本
- 回顾性阅读研究,纳入两个筛查中心793例因筛查乳腺X线发现异常而被召回补充摄影的女性(平均年龄50±9岁),由三名乳腺专科放射科医生在同一场次中逐例序贯在有和无AI辅助下判读。
诊断标准与关键数值
- AI辅助前后读者平均AUC分别为0.79(95%CI 0.74-0.85)和0.89(95%CI 0.85-0.94)(p<0.001);读者平均特异度分别为41.9%(95%CI 39.3%-44.5%)和53.9%(95%CI 50.9%-56.9%)(p<0.001);读者平均敏感度分别为89.5%(95%CI 83.1%-95.9%)和92.6%(95%CI 86.2%-99.0%)(p=0.053),无统计学差异;经验最少放射科医生AI辅助前后敏感度分别为79.6%(43/54,95%CI 66.5%-89.4%)和90.7%(49/54,95%CI 79.7%-96.9%)(p=0.031);读者平均召回率AI辅助后从60.4%(95%CI 57.8%-62.9%)降至49.5%(95%CI 46.5%-52.4%)(p<0.001)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To conduct a simulation study to determine whether artificial intelligence (AI)-aided mammography reading can reduce unnecessary recalls while maintaining cancer detection ability in women recalled after mammography screening.
MATERIALS AND METHODS: A retrospective reader study was performed by screening mammographies of 793 women (mean age ± standard deviation, 50 ± 9 years) recalled to obtain supplemental mammographic views regarding screening mammography-detected abnormalities between January 2016 and December 2019 at two screening centers. Initial screening mammography examinations were interpreted by three dedicated breast radiologists sequentially, case by case, with and without AI aid, in a single session. The area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and recall rate for breast cancer diagnosis were obtained and compared between the two reading modes.
RESULTS: Fifty-four mammograms with cancer (35 invasive cancers and 19 ductal carcinomas in situ) and 739 mammograms with benign or negative findings were included. The reader-averaged AUC improved after AI aid, from 0.79 (95% confidence interval [CI], 0.74-0.85) to 0.89 (95% CI, 0.85-0.94) (p < 0.001). The reader-averaged specificities before and after AI aid were 41.9% (95% CI, 39.3%-44.5%) and 53.9% (95% CI, 50.9%-56.9%), respectively (p < 0.001). The reader-averaged sensitivity was not statistically different between AI-unaided and AI-aided readings: 89.5% (95% CI, 83.1%-95.9%) vs. 92.6% (95% CI, 86.2%-99.0%) (p = 0.053), although the sensitivities of the least experienced radiologists before and after AI aid were 79.6% (43 of 54 [95% CI, 66.5%-89.4%]) and 90.7% (49 of 54 [95% CI, 79.7%-96.9%]), respectively (p = 0.031). With AI aid, the reader-averaged recall rate decreased by from 60.4% (95% CI, 57.8%-62.9%) to 49.5% (95% CI, 46.5%-52.4%) (p < 0.001).
CONCLUSION: AI-aided reading reduced the number of recalls and improved the diagnostic performance in our simulation using women initially recalled for supplemental mammographic views after mammography screening.
引用
- Kim YS, Jang MJ, Lee SH, et al. Use of Artificial Intelligence for Reducing Unnecessary Recalls at Screening Mammography: A Simulation Study. Korean J Radiol. 2022. PMID: 36447412. doi:10.3348/kjr.2022.0263