文献速递腹部儿科影像外周血管CT

基于X射线相位对比CT揭示胆道闭锁患者Kasai门肠吻合术后Glisson系统微血管适应性改变

Insight into microvascular adaptive alterations in the Glisson system of biliary atresia after Kasai portoenterostomy using X-ray phase-contrast CT.
PubMed 文献 · Eur Radiol · 2022-12-28

该研究利用X射线相位对比CT对胆道闭锁患者肝标本进行三维虚拟组织病理学评估,比较Kasai门肠吻合术组(n=16)与非手术组(n=16)Glisson系统微血管改变。术后组胆管增生减少、胆管环体积比降低13.89%,动脉三维空间密度降低3.53%、相对表面积从0.088±0.035降至0.039±0.015(p<.01),门静脉分支密度增加2.93%、迂曲度从1.17±0.06降至1.14±0.04(p<.01)。三维虚拟组织病理学清晰呈现了Glisson系统微血管形态及病理改变。

要点

  • X射线相位对比CT三维虚拟组织病理学可清晰显示胆道闭锁患者Glisson系统微血管结构及病理改变。
  • Kasai术后组胆管环体积比较非手术组降低13.89%,动脉三维空间密度降低3.53%。
  • Kasai术后组动脉相对表面积由非手术组0.088±0.035降至0.039±0.015(p<.01),门静脉迂曲度由1.17±0.06降至1.14±0.04(p<.01)。

核心结论

  • 基于X射线相位对比CT的三维虚拟组织病理学清晰揭示了胆道闭锁患者Glisson系统微血管结构,为Kasai术后胆道疏通诱导的微血管适应性改变的形态学机制提供了关键见解。

研究设计与样本

  • 研究论文;肝标本离体影像学研究,共纳入32例受试者,分为Kasai门肠吻合术组(n=16)与非Kasai组(n=16);采用X射线相位对比CT成像,结合组织学分析与三维可视化技术进行胆道、动脉和门静脉系统的三维虚拟组织病理学评估;参考标准为组织学分析。

关键影像表现/征象

  • 非Kasai组胆管多表现为放射状多分支增生并扭曲成环,Kasai组胆管增生较少。
  • 动脉和门静脉系统随胆管增生程度呈现适应性改变。
  • Kasai组门静脉分支变形逐渐恢复,三维空间密度较非Kasai组增加2.93%,迂曲度由1.17±0.06降至1.14±0.04(p<.01)。

诊断标准与关键数值

  • 采用环体积比、三维空间密度、相对表面积、迂曲度等参数评估Glisson系统微血管病理改变。
  • Kasai组胆管环体积比较非Kasai组降低13.89%。
  • Kasai组动脉三维空间密度较非Kasai组降低3.53%,相对表面积由0.088±0.035降至0.039±0.015(p<.01)。

临床应用与阅片要点

  • X射线相位对比CT三维虚拟组织病理学可用于显示胆道闭锁患者Glisson系统微血管形态结构及病理改变。
  • Glisson系统微血管形态改变在胆道闭锁过程中遵循竞争性占据机制。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate microvascular alterations in the Glisson system of biliary atresia (BA) patients after Kasai portoenterostomy (KP) using three-dimensional (3D) virtual histopathology based on X-ray phase-contrast CT (PCCT).

METHODS: Liver explants from BA patients were imaged using PCCT, and 32 subjects were included and divided into two groups: KP (n = 16) and non-KP (n = 16). Combined with histological analysis and 3D visualization technology, 3D virtual histopathological assessment of the biliary, arterial, and portal venous systems was performed. According to loop volume ratio, 3D spatial density, relative surface area, tortuosity, and other parameters, pathological changes of microvasculature in the Glisson system were investigated.

RESULTS: In the non-KP group, bile ducts mostly manifested as radial multifurcated hyperplasia and twisted into loops. In the KP group, the bile duct hyperplasia was less, and the loop volume ratio of bile ducts decreased by 13.89%. Simultaneously, the arterial and portal venous systems presented adaptive alterations in response to degrees of bile duct hyperplasia. Compared with the non-KP group, the 3D spatial density of arteries in the KP group decreased by 3.53%, and the relative surface area decreased from 0.088 ± 0.035 to 0.039 ± 0.015 (p < .01). Deformed portal branches gradually recovered after KP, with a 2.93% increase in 3D spatial density and a decrease in tortuosity from 1.17 ± 0.06 to 1.14 ± 0.04 (p < .01) compared to the non-KP group.

CONCLUSION: 3D virtual histopathology via PCCT clearly reveals the microvascular structures in the Glisson system of BA patients and provides key insights into the morphological mechanism of microvascular adaptation induced by biliary tract dredging after KP in BA disease.

KEY POINTS: • 3D virtual histopathology via X-ray phase-contrast computed tomography clearly presented the morphological structures and pathological changes of microvasculature in the Glisson system of biliary atresia patients. • The morphological alterations of microvasculature in the Glisson system followed the competitive occupancy mechanism in the process of biliary atresia.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Qi BN, Lv WJ, Jian JB, et al. Insight into microvascular adaptive alterations in the Glisson system of biliary atresia after Kasai portoenterostomy using X-ray phase-contrast CT. Eur Radiol. 2022. PMID: 36576546. doi:10.1007/s00330-022-09364-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。