双层光谱探测器计算机断层扫描在胰腺神经内分泌肿瘤诊断中的应用
本回顾性分析纳入134例胰腺神经内分泌肿瘤患者共136个病灶,均行对比增强双层光谱探测器CT扫描并经组织病理学证实。研究比较40-100 keV虚拟单能图像、碘浓度图、Z有效原子序数图与常规图像的客观和主观质量及病灶检出率,发现VMI40keV的SNR和CNR最高,Zeff图和IC图的主观评分优于常规图像和VMI40keV,双层光谱探测器CT图像检出性能优于常规图像。
要点
- VMI40keV在动脉期和静脉期的SNR和CNR均最高,是胰腺神经内分泌肿瘤显示的最佳虚拟单能级。
- Zeff图和IC图的主观图像质量评分高于常规图像和VMI40keV(P < 0.05)。
- 双层光谱探测器CT图像的病灶检出性能优于常规图像。
核心结论
- VMI40keV相比其他虚拟单能图像显示胰腺神经内分泌肿瘤最佳的CNR和SNR,Zeff图和IC图相比常规图像提高客观图像质量和阅片者偏好,这些发现可能对制定治疗策略具有重要临床意义。
研究设计与样本
- 回顾性分析纳入134例胰腺神经内分泌肿瘤患者共136个病灶,均行对比增强双层光谱探测器CT扫描并经组织病理学证实。
诊断标准与关键数值
- VMI40keV的SNR和CNR最高:40-80 keV VMI的SNR高于常规图像(动脉期P < 0.001,静脉期P < 0.05),40-60 keV的CNR高于常规图像(动脉期和静脉期各P < 0.05)。
- 两名阅片者间一致性良好(Kappa值 > 0.61),Zeff图和IC图的主观评分高于常规图像和VMI40keV(P < 0.05)。
- 双层光谱探测器CT图像的病灶检出性能优于常规图像。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To explore the optimal energy level of dual-layer spectral detector computed tomography (DLCT) images of pancreatic neuroendocrine neoplasms (pNENs) and investigate the value in their detection.
METHODS: This retrospective analysis included 134 pNEN patients with 136 lesions; they underwent contrast-enhanced DLCT scanning with histopathological confirmation of pNENs. Virtual monoenergetic images (VMI) of 40-100 keV, iodine concentration map (IC map), Z-effective atomic number map (Zeff map), and conventional images were analysed. The optimal energy level was obtained by comparing the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The lesion detection rates of DLCT and conventional images were compared. Subjective image analysis was performed by two readers who assessed the image quality and lesion conspicuity on a 5-point scale.
RESULTS: The SNR of VMIs from 40 to 80 keV (arterial phase, P < 0.001; venous phase, P < 0.05) and CNR from 40 to 60 keV (arterial and venous phases, each P < 0.05) were higher than that of conventional images; VMI40keV showed the highest SNR and CNR. There was a good inter-reader agreement between the two reviewers (Kappa values > 0.61); the scores of Zeff and IC maps were higher than those of conventional images and VMI40keV (P < 0.05). The detection performance of DLCT images was better than conventional images.
CONCLUSIONS: The VMI40keV demonstrated the best CNR and SNR of pNENs compared to other VMIs. Zeff and IC maps improve objective image quality and reader preference compared to conventional images. These findings could possess important clinical implications in formulating treatment strategies.
引用
- Yuan J, Wang Y, Hu X, et al. Use of dual-layer spectral detector computed tomography in the diagnosis of pancreatic neuroendocrine neoplasms. Eur J Radiol. 2022. PMID: 36577182. doi:10.1016/j.ejrad.2022.110660
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。