文献速递神经技术与安全MR

基于机器学习的多参数磁共振成像影像组学模型用于区分侧脑室中枢神经细胞瘤与胶质瘤

Machine learning-based multiparametric magnetic resonance imaging radiomics model for distinguishing central neurocytoma from glioma of lateral ventricle.
PubMed 文献 · Eur Radiol · 2022-12-22

本研究纳入两个医疗中心的132例患者,回顾性构建基于多参数MRI的机器学习影像组学模型,用于术前区分侧脑室中枢神经细胞瘤与胶质瘤。模型在训练组、内部验证组和外部验证组的AUC分别为0.986、0.933和0.903,优于三位放射科医师的AUC(0.657–0.838、0.786–0.799、0.708–0.790)。在影像组学模型辅助下,两位放射科医师仅在训练组中表现提升(p < 0.05),在内部和外部验证组中未提升。

要点

  • 影像组学模型区分侧脑室中枢神经细胞瘤与胶质瘤的AUC在外部验证组为0.903。
  • 模型AUC(0.90)优于两位经验丰富放射科医师(0.79和0.86)。
  • 模型辅助仅在训练组提升两位医师表现(p < 0.05),验证组未提升。

核心结论

  • 基于多参数MRI的机器学习影像组学模型在区分中枢神经细胞瘤与侧脑室胶质瘤方面表现优于经验丰富的放射科医师,并显示出提升放射科医师表现的潜力。

研究设计与样本

  • 回顾性研究,纳入两个医疗中心共132例患者;第一中心分为训练组(n = 74)和内部验证组(n = 30),第二中心为外部验证组(n = 28);从增强T1加权和T2加权图像提取特征,采用支持向量机建立影像组学模型。

诊断标准与关键数值

  • 影像组学模型AUC在训练组为0.986、内部验证组为0.933、外部验证组为0.903;放射科医师1的AUC在三组分别为0.657、0.786、0.708,医师2分别为0.838、0.799、0.790,医师3分别为0.827、0.871、0.862。

临床应用与阅片要点

  • 作者认为该模型在区分中枢神经细胞瘤与侧脑室胶质瘤方面表现优于经验丰富的放射科医师,并显示出提升放射科医师表现的潜力;模型辅助下两位放射科医师仅在训练组表现提升(p < 0.05),在内部和外部验证组未提升。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To develop a machine learning-based radiomics model based on multiparametric magnetic resonance imaging (MRI) for preoperative discrimination between central neurocytomas (CNs) and gliomas of lateral ventricles.

METHODS: A total of 132 patients from two medical centers were enrolled in this retrospective study. Patients from the first medical center were divided into a training cohort (n = 74) and an internal validation cohort (n = 30). Patients from the second medical center were used as the external validation cohort (n = 28). Features were extracted from contrast-enhanced T1-weighted and T2-weighted images. A support vector machine was used for radiomics model investigation. Performance was evaluated using the sensitivity, specificity, and the area under the receiver operating characteristic curve (AUC). The model's performance was also compared with those of three radiologists.

RESULTS: The radiomics model achieved an AUC of 0.986 in the training cohort, 0.933 in the internal validation cohort, and 0.903 in the external validation cohort. In the three cohorts, the AUC values were 0.657, 0.786, and 0.708 for radiologist 1; 0.838, 0.799, and 0.790 for radiologist 2; and 0.827, 0.871, and 0.862 for radiologist 3. When assisted by the radiomics model, two radiologists improved their performance in the training cohort (p < 0.05) but not in the internal or external validation cohorts.

CONCLUSIONS: The machine learning radiomics model based on multiparametric MRI showed better performance for distinguishing CNs from lateral ventricular gliomas than did experienced radiologists, and it showed the potential to improve radiologist performance.

KEY POINTS: • The machine learning radiomics model shows excellent performance in distinguishing CNs from gliomas. • The radiomics model outweighs two experienced radiologists (area under the receiver operating characteristic curve, 0.90 vs 0.79 and 0.86, respectively). • The radiomics model has the potential to enhance radiologist performance.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Mo H, Liang W, Huang Z, et al. Machine learning-based multiparametric magnetic resonance imaging radiomics model for distinguishing central neurocytoma from glioma of lateral ventricle. Eur Radiol. 2022. PMID: 36547672. doi:10.1007/s00330-022-09319-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。