FLAIR血管高信号作为急性卒中侧支循环的替代标志物:DWI至关重要
本研究回顾性纳入6家卒中中心209例前循环大血管闭塞急性卒中患者,以PWI侧支血流图(1-4级,3-4级为良好)为参考,比较全部FLAIR血管高信号与FLAIR血管高信号-DWI不匹配对侧支循环的评估价值。结果显示FLAIR血管高信号-DWI不匹配预测良好侧支的AUC为0.80(95%CI 0.74-0.87),优于全部FLAIR血管高信号的AUC 0.52(95%CI 0.44-0.60),两者比较P<.001。
要点
- 评估侧支循环时,FLAIR血管高信号需结合DWI计算不匹配范围,全部FLAIR血管高信号不能可靠反映侧支状态。
- FLAIR血管高信号-DWI不匹配预测良好侧支的AUC为0.80(95%CI 0.74-0.87),全部FLAIR血管高信号为0.52(95%CI 0.44-0.60)。
- 良好侧支独立相关因素为较小DWI病灶体积(P<.001)和较大FLAIR血管高信号-DWI不匹配(P=.02)。
核心结论
- 在急性前循环大血管闭塞性卒中中,除非同时考虑DWI,否则FLAIR血管高信号的范围不能可靠反映侧支循环状态。
研究设计与样本
- 回顾性研究,纳入6家大型卒中中心209例前循环大血管闭塞急性卒中患者,血栓切除术前接受包含PWI的MR成像,以PWI衍生侧支血流图(1-4级)为参考标准。
关键影像表现/征象
- 全部FLAIR血管高信号范围在良好侧支组与不良侧支组间相似(P=.76)。
- FLAIR血管高信号-DWI不匹配范围在良好侧支组显著高于不良侧支组(P<.001)。
- 侧支状态在PWI衍生侧支血流图上分为1-4级,二分为良好(3-4级)和不良(1-2级)。
诊断标准与关键数值
- 全部FLAIR血管高信号及FLAIR血管高信号-DWI不匹配范围在7个皮质ASPECTS区域上评估,评分0(无)至7(广泛)。
- FLAIR血管高信号-DWI不匹配预测良好侧支的AUC为0.80(95%CI 0.74-0.87)。
- 全部FLAIR血管高信号预测良好侧支的AUC为0.52(95%CI 0.44-0.60),两者比较P<.001。
临床应用与阅片要点
- 阅片评估侧支循环时,应关注FLAIR血管高信号超出DWI病灶的范围(即不匹配),而非全部FLAIR血管高信号。
- FLAIR血管高信号-DWI不匹配范围越大,提示良好侧支的可能性越高。
- 较小DWI病灶体积与良好侧支独立相关(P<.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: FLAIR vascular hyperintensities are thought to represent leptomeningeal collaterals in acute ischemic stroke. However, whether all-FLAIR vascular hyperintensities or FLAIR vascular hyperintensities-DWI mismatch, ie, FLAIR vascular hyperintensities beyond the DWI lesion, best reflects collaterals remains debated. We aimed to compare the value of FLAIR vascular hyperintensities-DWI mismatch versus all-FLAIR vascular hyperintensities for collateral assessment using PWI-derived collateral flow maps as a reference.
MATERIALS AND METHODS: We retrospectively reviewed the registries of 6 large stroke centers and included all patients with acute stroke with anterior circulation large-vessel occlusion who underwent MR imaging with PWI before thrombectomy. Collateral status was graded from 1 to 4 on PWI-derived collateral flow maps and dichotomized into good (grades 3-4) and poor (grades 1-2). The extent of all-FLAIR vascular hyperintensities and FLAIR vascular hyperintensities-DWI mismatch was assessed on the 7 cortical ASPECTS regions, ranging from 0 (absence) to 7 (extensive), and associations with good collaterals were compared using receiver operating characteristic curves.
RESULTS: Of the 209 included patients, 133 (64%) and 76 (36%) had good and poor collaterals, respectively. All-FLAIR vascular hyperintensity extent was similar between collateral groups (P = .76). Conversely, FLAIR vascular hyperintensities-DWI mismatch extent was significantly higher in patients with good compared with poor collaterals (P < .001). The area under the curve was 0.80 (95% CI, 0.74-0.87) for FLAIR vascular hyperintensities-DWI mismatch and 0.52 (95% CI, 0.44-0.60) for all-FLAIR vascular hyperintensities (P < .001 for the comparison), to predict good collaterals. Variables independently associated with good collaterals were smaller DWI lesion volume (P < .001) and larger FLAIR vascular hyperintensities-DWI mismatch (P = .02).
CONCLUSIONS: In acute ischemic stroke with large-vessel occlusion, the extent of FLAIR vascular hyperintensities does not reliably reflect collateral status unless one accounts for DWI.
引用
- Legrand L, Le Berre A, Seners P, et al. FLAIR Vascular Hyperintensities as a Surrogate of Collaterals in Acute Stroke: DWI Matters. AJNR Am J Neuroradiol. 2022. PMID: 36521962. doi:10.3174/ajnr.A7733
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。