文献速递心血管MR

自由呼吸心脏电影MRI联合压缩感知实时成像与回顾性运动校正:临床可行性与验证

Free-breathing cardiac cine MRI with compressed sensing real-time imaging and retrospective motion correction: clinical feasibility and validation.
PubMed 文献 · Eur Radiol · 2022-11-10

该前瞻性研究纳入80例临床心脏MRI患者,在3.0T下比较屏气分段电影(SegBH)、实时压缩感知电影联合运动校正(RTCSCineMoCo)与单次激发实时压缩感知电影(RTCSCine)三种技术。RTCSCineMoCo与SegBH图像质量评分无显著差异(4.4±0.7 vs 4.2±0.8,p=0.066),且双心室定量参数相似;RTCSCine图像质量评分显著低于SegBH(4.0±0.8 vs 4.2±0.8,p=0.031),多数定量参数与SegBH显著不同(LVEDV除外)。

要点

  • RTCSCineMoCo与SegBH图像质量评分无显著差异(4.4±0.7 vs 4.2±0.8,p=0.066)。
  • RTCSCineMoCo与SegBH的双心室定量参数相似,而RTCSCine多数参数与SegBH显著不同(LVEDV除外)。
  • RTCSCineMoCo可能适用于常规临床中对传统分段电影技术成像困难的患者。

核心结论

  • RTCSCineMoCo是一种有前景的自由呼吸心脏电影成像方法,与RTCSCine相比可获得更好的图像质量和更精确的双心室定量分析结果。

研究设计与样本

  • 前瞻性研究,纳入80例拟行临床心脏MRI的患者,在3.0T下采集相同长轴和短轴层面的三种技术图像:屏气分段电影(SegBH)、实时压缩感知电影联合运动校正(RTCSCineMoCo)、单次激发实时压缩感知电影(RTCSCine)。

诊断标准与关键数值

  • 图像质量采用5点Likert量表定性评估,并参照欧洲CMR注册标准化标准;定量参数包括左心室和右心室射血分数、舒张末期容积、收缩末期容积、每搏输出量和左心室质量。RTCSCineMoCo与SegBH图像质量评分无显著差异(4.4±0.7 vs 4.2±0.8,p=0.066);RTCSCine图像质量评分显著低于SegBH(4.0±0.8 vs 4.2±0.8,p=0.031)。RTCSCineMoCo与SegBH所有定量参数相似;RTCSCine多数参数与SegBH显著不同,LVEDV除外。

临床应用与阅片要点

  • RTCSCineMoCo可能适用于常规临床中对传统分段电影技术成像困难的患者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To prospectively evaluate the feasibility and biventricular assessment accuracy of a free-breathing cardiac cine imaging technique (RTCSCineMoCo) combined with highly accelerated real-time (RT) acquisition, compressed sensing (CS) reconstruction, and fully automated non-rigid respiratory motion correction.

METHODS: We evaluated 80 patients scheduled for clinical cardiac MRI. Cardiac cine images of the same long-axis and short-axis stacks were acquired using three techniques: (1) SegBH: standard segmented cine with breath-hold; (2) RTCSCineMoCo; (3) RTCSCine: single-shot RT CS cine at 3.0 T. Image quality (IQ) was evaluated using a qualitative 5-point Likert scale and the European CMR registry standardized criteria. Quantitative parameters including left (LV) and right ventricular (RV) ejection fractions (EF), end-diastolic volumes (EDV), end-systolic volumes (ESV), stroke volumes (SV), and LV mass (LVM) were measured and compared.

RESULTS: RTCSCineMoCo and SegBH had equivalent IQ scores (4.4 ± 0.7 vs. 4.2 ± 0.8, p = 0.066), while RTCSCine had a significantly lower IQ score than SegBH (4.0 ± 0.8 vs. 4.2 ± 0.8, p = 0.031). In a quantitative analysis, RTCSCineMoCo and SegBH yielded similar measurements for all parameters, while the majority of RTCSCine parameters were significantly different compared with SegBH, except for LVEDV.

CONCLUSION: RTCSCineMoCo is a promising method for robust free-breathing cardiac cine imaging, achieving better IQ and more precise quantitative analysis results for both ventricles compared with RTCSCine.

KEY POINTS: • RTCSCineMoCo is a promising method for free-breathing cardiac MR cine imaging in daily practice. • RTCSCineMoCo provided better IQ and more precise quantitative measurements compared with RTCSCine, by extending RT data acquisition to multiple heartbeats, performing non-rigid respiratory motion correction, and signal averaging. • RTCSCineMoCo may be suitable for routine clinical use for vulnerable patients who may otherwise pose a challenge to image successfully with the conventional segmented cine technique.

来源:Eur Radiol,查看原文。版权归原作者所有。