重组组织型纤溶酶原激活剂与120 kHz超声对猪颅内血栓密度的影响

Effect of Recombinant Tissue Plasminogen Activator and 120-kHz Ultrasound on Porcine Intracranial Thrombus Density.
PubMed 文献 · Ultrasound Med Biol · 2022-11-03

在幼年猪脑出血模型中,直接注入自体血制作血栓,分别不治疗、单用重组组织型纤溶酶原激活剂(rt-PA)或联用脉冲经颅120 kHz超声,治疗后取血栓用D-二聚体和血栓密度检测评估溶解程度;rt-PA单用或联用超声组血栓密度均显著低于假手术组,但加用120 kHz超声未增强rt-PA介导的溶栓效果。

要点

  • 在幼年猪脑出血模型中,rt-PA单用或联用120 kHz超声组血栓密度均显著低于假手术组。
  • 加用120 kHz超声未增强rt-PA介导的溶栓效果,可能与缺乏外源性空化核有关。
  • 所用猪和人类D-二聚体检测均灵敏度不足,无法检出猪D-二聚体。

核心结论

  • rt-PA在幼年猪脑出血体内模型中显示溶栓效果,但经颅超声溶栓未增强rt-PA诱导的溶栓作用,可能因缺乏外源性空化核。

研究设计与样本

  • 幼年猪脑出血模型:向猪白质直接注入自体血制作血栓,分为不治疗(假手术)、单用rt-PA、rt-PA联合脉冲经颅120 kHz超声(超声溶栓)组;治疗后处死、冻头切片并取出血栓,用D-二聚体和血栓密度检测评估溶解程度。

关键影像表现/征象

  • rt-PA单用或联用120 kHz超声组血栓密度均显著低于假手术组。
  • 加用120 kHz超声未见增强rt-PA介导的溶栓效果。
  • 所用猪和人类D-二聚体检测均灵敏度不足,无法检出猪D-二聚体。

局限性

  • 所用猪和人类D-二聚体检测均灵敏度不足,无法检出猪D-二聚体。
  • 加用120 kHz超声未增强rt-PA溶栓效果,原文认为可能与缺乏外源性空化核有关。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Surgical intervention for the treatment of intracerebral hemorrhage (ICH) has been limited by inadequate lysis of the target thrombus. Adjuvant transcranial ultrasound exposure is hypothesized to improve thrombolysis, expedite hematoma evacuation and improve clinical outcomes. A juvenile porcine intracerebral hemorrhage model was established by direct infusion of autologous blood into the porcine white matter. Thrombi were either not treated (sham) or treated with recombinant tissue plasminogen activator alone (rt-PA only) or in combination with pulsed transcranial 120-kHz ultrasound (sonothrombolysis). After treatment, pigs were euthanized, the heads frozen and sectioned and the thrombi extracted. D-Dimer and thrombus density assays were used to assess degree of lysis. Both porcine and human D-dimer assays tested did not have sufficient sensitivity to detect porcine D-dimer. Thrombi treated with rt-PA with or without 120-kHz ultrasound had a significantly lower density compared with sham-treated thrombi. No enhancement of rt-PA-mediated thrombolysis was noted with the addition of 120-kHz ultrasound (sonothrombolysis). The thrombus density assay revealed thrombolytic efficacy caused by rt-PA in an in vivo juvenile porcine model of intracerebral hemorrhage. Transcranial sonothrombolysis did not enhance rt-PA-induced thrombolysis, likely because of the lack of exogenous cavitation nuclei.