指南与共识心血管CT

CAD-RADS™ 2.0——2022 冠状动脉疾病报告与数据系统:美国心血管计算机断层扫描学会(SCCT)、美国心脏病学会(ACC)、美国放射学会(ACR)与北美心血管影像学会(NASCI)的专家共识文件

CAD-RADS™ 2.0 - 2022 Coronary Artery Disease - Reporting and Data System.: An expert consensus document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Cardiology (ACC), the American College of Radiology (ACR) and the North America Society of Cardiovascular Imaging (NASCI).
指南 / 共识 · J Am Coll Radiol · 2022-01-01

CAD-RADS 是为冠状动脉 CT 血管成像(CCTA)患者标准化报告并指导后续管理而创建的系统。2022 年更新的 CAD-RADS 2.0 纳入心脏 CT 新技术进展、近期临床试验数据和新临床指南,沿用狭窄、斑块负荷与修饰符的框架,加入 CT-FFR 或心肌 CT 灌注评估病变特异性缺血,并新增 P1 至 P4 斑块负荷描述符。狭窄严重程度分类以每患者最严重冠状动脉管腔狭窄为准,从 CAD-RADS 0(无斑块或狭窄)到 CAD-RADS 5(至少一支冠状动脉完全闭塞)。

要点

  • 狭窄分级以每患者最严重冠状动脉管腔狭窄为准,从 CAD-RADS 0 到 CAD-RADS 5。
  • P1 至 P4 描述符用于表示递增的斑块负荷类别。
  • 在实施时,可使用 CT-FFR 或心肌 CT 灌注评估病变特异性缺血。

核心结论

  • CAD-RADS 2.0 旨在改进 CCTA 初始报告系统,标准化报告以便与转诊医师沟通检查结果并提供后续患者管理建议,同时应始终结合报告中的印象解读。

研究设计与样本

  • 由美国心血管计算机断层扫描学会(SCCT)、美国心脏病学会(ACC)、美国放射学会(ACR)与北美心血管影像学会(NASCI)共同制定的专家共识文件,纳入近期临床试验数据和新临床指南。

诊断标准与关键数值

  • 狭窄严重程度分类以每患者最严重冠状动脉管腔狭窄为准,范围从 CAD-RADS 0(无任何斑块或狭窄)到 CAD-RADS 5(至少一支冠状动脉完全闭塞)。
  • P1 至 P4 描述符用于表示递增的斑块负荷类别。
  • 在实施时,使用 CT 分数血流储备(CT-FFR)或心肌 CT 灌注(CTP)评估病变特异性缺血。

临床应用与阅片要点

  • CAD-RADS 应始终结合报告中的印象解读。
  • 报告应促进与转诊医师沟通检查结果并提供后续患者管理建议。
  • 报告应包含基于每患者最严重冠状动脉管腔狭窄的狭窄严重程度分类。
  • 报告应使用 P1 至 P4 描述符表示斑块负荷类别。
  • 在实施 CT-FFR 或心肌 CT 灌注时,应评估病变特异性缺血。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Coronary Artery Disease Reporting and Data System (CAD-RADS) was created to standardize reporting system for patients undergoing coronary CT angiography (CCTA) and to guide possible next steps in patient management. The goal of this updated 2022 CAD-RADS 2.0 is to improve the initial reporting system for CCTA by considering new technical developments in Cardiac CT, including data from recent clinical trials and new clinical guidelines. The updated CAD-RADS classification will follow an established framework of stenosis, plaque burden, and modifiers, which will include assessment of lesion-specific ischemia using CT fractional-flow-reserve (CT-FFR) or myocardial CT perfusion (CTP), when performed. Similar to the method used in the original CAD-RADS version, the determinant for stenosis severity classification will be the most severe coronary artery luminal stenosis on a per-patient basis, ranging from CAD-RADS 0 (zero) for absence of any plaque or stenosis to CAD-RADS 5 indicating the presence of at least one totally occluded coronary artery. Given the increasing data supporting the prognostic relevance of coronary plaque burden, this document will provide various methods to estimate and report total plaque burden. The addition of P1 to P4 descriptors are used to denote increasing categories of plaque burden. The main goal of CAD-RADS, which should always be interpreted together with the impression found in the report, remains to facilitate communication of test results with referring physicians along with suggestions for subsequent patient management. In addition, CAD-RADS will continue to provide a framework of standardization that may benefit education, research, peer-review, artificial intelligence development, clinical trial design, population health and quality assurance with the ultimate goal of improving patient care.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Cury RC, Leipsic J, Abbara S, et al. CAD-RADS™ 2.0 - 2022 Coronary Artery Disease - Reporting and Data System.: An expert consensus document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Cardiology (ACC), the American College of Radiology (ACR) and the North America Society of Cardiovascular Imaging (NASCI). J Am Coll Radiol. 2022. PMID: 36436841. doi:10.1016/j.jacr.2022.09.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。