胎盘植入谱系的彩色与频谱多普勒宫内血流模式与特征
对32例有胎盘植入谱系(PAS)风险的患者行彩色与频谱多普勒超声,19例最终证实PAS、13例无PAS。PAS组下段宫内血管簇(95% vs 23%)、簇内母体动脉波形(84% vs 15%)及穿越的胎儿动脉(84% vs 15%)均显著更常见,观察者间一致性良好至优秀。
要点
- 下段宫内血管簇伴低阻母体动脉血流提示PAS。
- 血管簇内可见穿越的胎儿动脉是PAS的特征之一。
- 静脉波形在PAS组占84%,无PAS组占15%。
核心结论
- PAS的宫内血流模式表现为宫内血管簇,内含低阻母体动脉血流及穿越胎盘的胎儿动脉。
研究设计与样本
- 前瞻性纳入32例有PAS风险的患者,行彩色与频谱多普勒超声,以分娩结局为参考标准,采用Fisher精确检验与Mann-Whitney U检验比较,并用kappa系数评估观察者间一致性。
关键影像表现/征象
- 下段宫内血管簇见于66%的病例,其中PAS组95%、无PAS组23%(p < 0.0001)。
- 血管簇内母体动脉波形见于PAS组84%、无PAS组15%(p < 0.0001)。
- 血管簇内穿越的胎儿动脉见于56%的病例,其中PAS组84%、无PAS组15%(p = 0.001)。
- 静脉波形见于PAS组84%、无PAS组15%。
临床应用与阅片要点
- 观察下段宫内血管簇时,应加用频谱多普勒区分母体动脉、胎儿动脉与静脉波形。
- 血管簇内低阻母体动脉血流及穿越的胎儿动脉支持PAS诊断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To characterize intraplacental blood flow patterns in placenta accreta spectrum (PAS) with color and spectral Doppler imaging.
METHODS: Thirty-two patients at risk for PAS underwent ultrasound imaging with both color and spectral Doppler. The placenta was inspected for areas of vascularity by color Doppler, particularly within the lower uterine segment. Spectral Doppler waveforms were obtained from these vessels and categorized as either intraplacental or subplacental (myometrial), venous or arterial, fetal or maternal (based on heart rate). Arterial waveforms were measured for heart rate, peak systolic velocity, end diastolic velocity, and resistive index. Statistical comparisons were made between cases with and without PAS using Fisher exact tests (categorical variables) and Mann-Whitney U tests (numerical indices). Interobserver agreement was characterized with kappa coefficients.
RESULTS: At delivery, there were 19 cases with PAS and 13 without PAS. On ultrasound studies, clustered intraplacental vascularity was found in the lower uterine segment in 66% of cases (95% of PAS cases and 23% cases without PAS; p < 0.0001). Maternal arterial waveforms were found within the vascular cluster in 84% of PAS cases and 15% of cases without PAS (p < 0.0001). A traversing fetal artery was found within the vascular cluster in 56% of cases (84% PAS cases and 15% cases without PAS; p = 0.001). Venous waveforms were found in 84% of PAS cases and 15% of cases without PAS. Interobserver agreement was good to excellent.
CONCLUSION: Intraplacental blood flow pattern in PAS is characterized by an intraplacental vascular cluster containing low-resistance maternal arterial flow and transplacental fetal arteries.
引用
- Kliewer MA, Bagley AR, Sadowski EA, et al. Placenta accreta spectrum: the pattern and character of intraplacental blood flow by color and spectral Doppler. Abdom Radiol (NY). 2022. PMID: 36273328. doi:10.1007/s00261-022-03708-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。