O-RADS超声与MRI评估大型复杂卵巢附件囊肿的阅片者间一致性与检查方式间 concordance
这项回顾性研究纳入54例女性共58个≥5 cm的复杂附件囊肿,评估O-RADS超声与MRI的阅片者间一致性及两种模态间的一致性。结果显示超声一致性为fair(κ=0.31),MRI为moderate(κ=0.43),超声与MRI之间为moderate(κ=0.58);O-RADS 4阈值在两种模态下准确率最高(AUC分别为0.92和0.995)。
要点
- O-RADS超声与MRI的阅片者间一致性分别为fair(κ=0.31)和moderate(κ=0.43)。
- 超声与MRI之间的O-RADS分类一致性为moderate(κ=0.58)。
- O-RADS 4阈值在超声和MRI中均获得最高准确率(AUC分别为0.92和0.995)。
核心结论
- O-RADS超声与MRI表现优异且呈正相关,但仍存在显著的观察者间变异。
研究设计与样本
- 回顾性研究,纳入54例女性共58个≥5 cm的复杂囊肿,来自电子超声数据库,2017年7月至2020年6月期间同时行超声和MRI检查;由两组各两名盲法放射科医师独立阅片分配O-RADS分类,分歧由仲裁者解决(共六名阅片者);记录病变结局(49个良性、8个恶性、1个失访)。
诊断标准与关键数值
- O-RADS超声与MRI的阅片者间一致性分别为fair(κ=0.31)和moderate(κ=0.43)。
- 超声与MRI之间的O-RADS分类一致性为moderate(κ=0.58)。
- O-RADS超声与MRI呈显著正相关(τ=0.72,P<.001)。
- O-RADS 4阈值在超声和MRI中准确率最高,AUC分别为0.92和0.995。
- 以O-RADS超声4或5为潜在恶性、1-3为良性时,8个超声评估为潜在恶性的病变经MRI表现正确降级为良性;1个超声评估为良性的恶性病变经MRI表现升级为潜在恶性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To assess interreader agreement of the Ovarian-Adnexal Reporting and Data System (O-RADS) and intermodality concordance between US and MRI for characterizing complex adnexal cysts measuring 5 cm or larger. Materials and Methods This retrospective study included 58 "complex cysts" measuring at least 5 cm in size observed at both US and MRI in 54 women (median age, 37 years ± 12 [SD]; seven postmenopausal women) between July 2017 and June 2020, identified from an electronic US database. A separate set of two blinded radiologists independently reviewed the US or MR images to assign the O-RADS category, and an adjudicator resolved discrepancies (a total of six readers). Lesion outcome (49 benign, eight malignant, one lost to follow-up) was recorded. Interreader agreement of O-RADS US and O-RADS MRI and concordance between US and MRI were analyzed. Results Interreader agreement was fair for US (κ = 0.31), moderate for MRI (κ = 0.43), and moderate between US and MRI (κ = 0.58). A significant positive correlation was found between O-RADS US and MRI (τ = 0.72, P < .001). The O-RADS 4 threshold yielded the highest accuracy for both US and MRI (area under the receiver operating characteristic curve = 0.92 and 0.995, respectively). Considering O-RADS US 4 or 5 as potentially malignant and 1-3 as benign, eight lesions that were assessed as potentially malignant at US were correctly downgraded to benign by using findings at MRI. Using findings at MRI, one malignant lesion that was assessed as benign at US was upgraded to potentially malignant. Conclusion O-RADS US and MRI had excellent performance and positive correlation, but significant interobserver variability remains. Keywords: Ovary, MR Imaging, Ultrasonography © RSNA, 2022 See also the commentary by Baumgarten in this issue.
引用
- Guo Y, Phillips CH, Suarez-Weiss K, et al. Interreader Agreement and Intermodality Concordance of O-RADS US and MRI for Assessing Large, Complex Ovarian-Adnexal Cysts. Radiol Imaging Cancer. 2022. PMID: 36178350. doi:10.1148/rycan.220064
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。