以肝活检为金标准比较视觉瞬时弹性成像、振动控制瞬时弹性成像、剪切波弹性成像与声触诊弹性成像在慢性肝病评估中的表现
研究纳入152例连续受试者,均行视觉瞬时弹性成像(ViTE)、振动控制瞬时弹性成像(VCTE)、剪切波弹性成像(SWE)和声触诊弹性成像(STE)检查,以肝活检为金标准。ViTE在慢性肝病分期鉴别中的表现与VCTE、SWE和STE相当;各方法诊断F≥F1至F=F4的AUC分别为0.9481–0.9900、0.9698–0.9931、0.9651–0.9846和0.9509–0.9656。观察者间和观察者内ICC分别为0.98和0.97。
要点
- ViTE诊断F≥F1至F=F4的AUC为0.9481–0.9846,与VCTE、SWE和STE相当。
- VCTE诊断F≥F1的AUC最高(0.9900),SWE诊断F≥F2的AUC最高(0.9931)。
- 观察者间ICC为0.98,观察者内ICC为0.97。
核心结论
- ViTE在慢性肝病分期鉴别中的表现与VCTE、SWE和STE相当。
研究设计与样本
- 152例连续受试者均行ViTE、VCTE、SWE和STE检查,以肝活检为金标准,并对各方法测得的硬度值行ROC分析及观察者间与观察者内分析。
诊断标准与关键数值
- ViTE诊断F≥F1、F≥F2、F≥F3和F=F4的AUC分别为0.9481、0.9698、0.9846和0.9524。
- VCTE诊断F≥F1、F≥F2、F≥F3和F=F4的AUC分别为0.9900、0.9767、0.9651和0.9645。
- SWE诊断F≥F1、F≥F2、F≥F3和F=F4的AUC分别为0.9621、0.9931、0.9835和0.9656。
- STE诊断F≥F1、F≥F2、F≥F3和F=F4的AUC分别为0.9683、0.9834、0.9763和0.9509。
- 观察者间ICC为0.98,观察者内ICC为0.97。
临床应用与阅片要点
- ViTE可作为慢性肝病分期评估的弹性成像方法之一,其诊断表现与VCTE、SWE和STE相当。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Chronic liver disease (CLD) is considered one of the main causes of death. Ultrasound Elastography (USE) is a CLD assessment imaging method. This study aims to evaluate a recently introduced commercial alternative of USE, Visual Transient Elastography (ViTE), and to compare it with three established USE methods, Vibration Controlled Transient Elastography (VCTE), Shear Wave Elastography (SWE) and Sound Touch Elastography (STE), using Liver Biopsy (LB) as 'Gold Standard'.
METHOD: 152 consecutive subjects underwent a liver ViTE, VCTE, SWE and STE examination. A Receiver Operator Characteristic (ROC) analysis was performed on the measured stiffness values of each method. An inter- intra-observer analysis was also performed.
RESULTS: The ViTE, VCTE, SWE and STE ROC analysis resulted in an AUC of 0.9481, 0.9900, 0.9621 and 0.9683 for F ≥ F1, 0.9698, 0.9767, 0.9931 and 0.9834 for F ≥ F2, 0.9846, 0.9651, 0.9835 and 0.9763 for F ≥ F3, and 0.9524, 0.9645, 0.9656, and 0.9509 for F = F4, respectively. ICC scores were 0.98 for Inter-observer and 0.97 for Intra-observer variability analysis.
CONCLUSION: ViTE performance in CLD stage differentiation is comparable to the performance of VCTE, SWE and STE.
引用
- Gatos I, Yarmenitis S, Theotokas I, et al. Comparison of Visual Transient Elastography, Vibration Controlled Transient Elastography, Shear Wave Elastography and Sound Touch Elastography in Chronic liver Disease assessment using liver biopsy as 'Gold Standard'. Eur J Radiol. 2022. PMID: 36274360. doi:10.1016/j.ejrad.2022.110557
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。