文献速递心血管MR

应用定量心脏磁共振参数检测免疫检查点抑制剂相关心肌炎的心肌病变

Applying quantitative CMR parameters for detecting myocardial lesion in immune checkpoint inhibitors-associated myocarditis.
PubMed 文献 · Eur J Radiol · 2022-10-17

该回顾性研究纳入2018年8月至2021年8月本院56例临床诊断的免疫检查点抑制剂相关心肌炎患者,评估T2 mapping、native T1、水肿比率及LGE范围等定量CMR参数。结果显示整体T2值升高率(92%)显著高于native T1异常率(73%)、ER(52%)和LGE存在率(68%);LGE范围与左心室射血分数负相关,与native T1值和细胞外容积正相关。

要点

  • T2 mapping检测ICI相关心肌炎的阳性率(92%)显著高于native T1(73%)、ER(52%)和LGE(68%)。
  • LGE范围与左心室射血分数呈负相关(r=-0.38,p=0.004)。
  • LGE范围与native T1值(r=0.28,p<0.04)和细胞外容积(r=0.50,p=0.001)呈正相关。

核心结论

  • T2 mapping检测ICI相关心肌炎患者的阳性率高于native T1 mapping、ER和LGE存在率;LGE范围与左心室射血分数负相关,与native T1值和细胞外容积正相关。

研究设计与样本

  • 回顾性研究,纳入2018年8月至2021年8月本院56例临床诊断的ICI相关心肌炎患者,临床诊断基于欧洲心脏病学会指南临床标准;采用多参数CMR图像包括T2 mapping和黑血T2加权成像评估心肌水肿。

关键影像表现/征象

  • ICI相关心肌炎患者整体T2值和native T1值显著高于本院参考范围(p<0.05);整体T2值升高率为92%,native T1异常率为73%,ER为52%,LGE存在率为68%;LGE extent为10.38±9.64%,左心室射血分数为56.42±8.54%。

诊断标准与关键数值

  • 心肌水肿判定采用T2加权成像上心肌水肿比率(ER)≥2.0;整体T2值升高率92%显著高于native T1异常率73%、ER 52%和LGE存在率68%(p<0.05)。

临床应用与阅片要点

  • 在疑诊ICI相关心肌炎时,T2 mapping对心肌水肿的检出率高于native T1 mapping、ER和LGE存在率,可优先关注整体T2值升高;LGE范围与左心室射血分数负相关,与native T1值和细胞外容积正相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Sparse researches evaluated the quantitative cardiovascular magnetic resonance (CMR) parameters for immune checkpoint inhibitors (ICI)-associated myocarditis. We aimed to apply quantitative CMR mappings and late gadolinium enhancement (LGE) extent for detecting ICI-associated myocarditis.

METHOD: The retrospective study included patients with ICI-associated myocarditis and CMR examination from August 2018 to August 2021 in our hospital. ICI-associated myocarditis was clinically diagnosed based on the clinical criteria by European Society of Cardiology guidelines. The multiparametric CMR images including T2 mapping and black blood T2-weighted images were used to evaluate myocardial edema. The myocardial edema ratio (ER) ≥ 2.0 was applied for determining myocardial edema on T2-weighted images.

RESULTS: 56 patients with ICI-associated myocarditis were included. The global T2 value and native T1 value of patients with ICI-associated myocarditis were significantly higher than the reference ranges in our hospital (p < 0.05). The rate of elevated global T2 value (92%) was significantly higher than those of abnormal native T1 value (73%), ER (52%) and LGE presence (68%) in patients with ICI-associated myocarditis (p < 0.05). The LGE extent and left ventricular ejection fraction of patients with ICI-associated myocarditis were 10.38 ± 9.64% and 56.42 ± 8.54%, respectively. LGE extent inversely correlated with left ventricular ejection fraction (r = -0.38, p = 0.004) but positively correlated with native T1 value (r = 0.28, p < 0.04) and extracellular volume (r = 0.50, p = 0.001).

CONCLUSIONS: T2 mapping could detect higher rate of patients with ICI-associated myocarditis than native T1 mapping, ER and LGE presence. LGE extent inversely correlated with left ventricular ejection fraction but positively correlated with native T1 value and extracellular volume in patients with ICI-associated myocarditis.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Zhao SH, Yun H, Chen CZ, et al. Applying quantitative CMR parameters for detecting myocardial lesion in immune checkpoint inhibitors-associated myocarditis. Eur J Radiol. 2022. PMID: 36265221. doi:10.1016/j.ejrad.2022.110558

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。