单能与双能CT联合人工智能诊断肺结节的比较
前瞻性研究将682例接受胸部双能CT检查的患者随机分为单能模式组(S组,341例)和双能模式组(D组,341例),先用AI肺结节检测软件自动分析图像,再由经验丰富的放射科医师分析结节数量、病灶大小和结节类型建立参考诊断,比较AI的准确率、敏感度、假阳性率和漏诊率。D组图像质量优于S组(对比噪声比0.16±0.10 vs 0.00±0.17),辐射剂量低于S组(0.32±0.10 vs 0.62±0.11 mSv.cm);与S组相比,D组在结节识别、大小分类和结节类型方面的敏感度显著更高、准确率更低(均p<0.05,5-10 mm和钙化结节除外)。双能CT可能显著提高AI诊断肺结节的敏感度,适用于大规模人群肺结节筛查,且图像质量改善、电离辐射暴露减少,但准确率较差。
要点
- 双能CT较单能CT可显著提高AI诊断肺结节的敏感度,但准确率更低。
- 双能CT图像质量优于单能CT,辐射剂量低于单能CT。
- 5-10 mm和钙化结节的比较除外,其余结节识别、大小分类和类型差异均有统计学意义。
核心结论
- 与单能CT相比,双能CT可能显著提高AI诊断肺结节的敏感度,适用于大规模人群肺结节筛查。
- 双能CT检查图像质量改善且电离辐射暴露减少,但准确率较差。
研究设计与样本
- 前瞻性研究,682例接受胸部双能CT检查的患者随机分为单能模式组(S组,n=341)和双能模式组(D组,n=341)。
- CT图像先用AI肺结节检测软件自动分析,再由经验丰富的放射科医师分析结节数量、病灶大小和结节类型建立参考诊断。
诊断标准与关键数值
- D组对比噪声比0.16±0.10 vs S组0.00±0.17,提示D组图像质量优于S组。
- D组辐射剂量0.32±0.10 mSv.cm vs S组0.62±0.11 mSv.cm,D组低于S组。
- 与S组相比,D组在结节识别、大小分类和结节类型方面敏感度显著更高、准确率更低(均p<0.05,5-10 mm和钙化结节除外)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To explore the efficiency of single- and dual-energy computed tomography (CT) with artificial intelligence (AI) for the diagnosis of pulmonary nodules.
MATERIALS AND METHODS: In a prospective study, 682 patients undergoing a chest CT examination using a dual-energy system were divided randomly into two groups: single-energy mode (group S, n=341) and dual-energy mode (group D, n=341). CT images were first analysed automatically with the AI pulmonary nodule-detection software. CT features including nodule number, lesion size, and nodule type were then analysed by experienced radiologists to establish a reference diagnosis. Subsequently, the accuracy, sensitivity, false-positive rate, and miss rate of AI were calculated. Additionally, image quality and radiation dose were also compared between the two groups.
RESULTS: The contrast-to-noise ratio data suggested that the image quality of group D was superior to that of group S (0.16 ± 0.10 versus 0.00 ± 0.17), and the radiation dose of group D was lower than that of group S (0.32 ± 0.10 versus 0.62 ± 0.11 mSv.cm). Compared to group S, group D exhibited a significantly higher sensitivity and lower accuracy for nodule identification, size classification, and nodule type (all p<0.05, except for 5-10 mm and calcified nodules).
CONCLUSIONS: Compared with single-energy CT, dual-energy CT may significantly improve the sensitivity of AI for the diagnosis of pulmonary nodules and is practical for the screening of pulmonary nodules in a large population. In addition, dual-energy CT examination demonstrates improved image quality and is associated with reduced exposure to ionising radiation, but its accuracy is poorer.
引用
- X Zhu, Zhu L, D Song, et al. Comparison of single- and dual-energy CT combined with artificial intelligence for the diagnosis of pulmonary nodules. Clin Radiol. 2022. PMID: 36266099. doi:10.1016/j.crad.2022.09.114
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。