3特斯拉结构MRI特征组合可准确刻画眼眶海绵状静脉畸形
本研究为单中心历史-前瞻性队列分析,纳入191例术前接受3T MRI的眼眶病变成人患者,其中30例(16%)为眼眶海绵状静脉畸形(OCVM)。两位阅片者盲法评估结构MRI特征,多因素分析得出两个特征组合:组合1(T2WI信号高于皮质+化学位移伪影)敏感度0.83、特异度0.94、准确率0.92;组合2(再加单一强化起点)敏感度0.97、特异度0.93、准确率0.93。结论认为结构MRI诊断OCVM具有高敏感度和特异度。
要点
- OCVM在T2WI上信号高于皮质者占89.7%(26/29),其他眼眶病变仅17.5%(28/160),P<0.001。
- OCVM出现化学位移伪影者占89.7%(26/29),其他病变仅10.3%(16/155),P<0.001。
- OCVM呈单一强化起点者占62.1%(18/29),其他病变仅2.5%(4/159),P=0.001。
核心结论
- 结构MRI诊断OCVM具有高敏感度和特异度;组合1(T2WI信号高于皮质+化学位移伪影)敏感度0.83、特异度0.94、准确率0.92,组合2(再加单一强化起点)敏感度0.97、特异度0.93、准确率0.93。
研究设计与样本
- IRB批准的历史-前瞻性单中心队列分析,纳入2015年12月至2021年5月术前接受3T MRI的连续成人眼眶病变患者191例,其中OCVM 30例(16%)、其他眼眶病变161例(84%)。
关键影像表现/征象
- OCVM在T2WI上信号强度高于皮质者26/29(89.7%),其他眼眶病变28/160(17.5%),P<0.001。
- OCVM出现化学位移伪影者26/29(89.7%),其他眼眶病变16/155(10.3%),P<0.001。
- OCVM呈单一强化起点者18/29(62.1%),其他眼眶病变4/159(2.5%),P=0.001。
诊断标准与关键数值
- 组合1(T2WI信号高于皮质+化学位移伪影)诊断OCVM的敏感度0.83、特异度0.94、准确率0.92。
- 组合2(组合1+单一强化起点)诊断OCVM的敏感度0.97、特异度0.93、准确率0.93。
临床应用与阅片要点
- 结构MRI特征组合(T2WI信号高于皮质、化学位移伪影、单一强化起点)可能易于用于常规临床实践。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To differentiate OCVM from other orbital lesions using structural MRI.
METHODS: This IRB-approved a historical-prospective cohort single-center analysis of a prospective cohort that included consecutive adult patients presenting with an orbital lesion undergoing a 3T MRI before surgery from December 2015 to May 2021. Two readers blinded to all data read all MRIs assessing structural MRI characteristics. A univariate analysis followed by a stepwise multivariate analysis identified structural MRI features showing the highest sensitivity and specificity when diagnosing OCVM.
RESULTS: One hundred ninety-one patients with 30/191 (16%) OCVM and 161/191 (84%) other orbital lesions were included. OCVM were significantly more likely to present with a higher signal intensity than that of the cortex on T2WI: 26/29 (89.7%) versus 28/160 (17.5%), p < 0.001, or with a chemical shift artifact (CSA): 26/29 (89.7%) versus 16/155 (10.3%), p < 0.001, or to present with a single starting point of enhancement, as compared to other orbital lesions: 18/29 (62.1%) versus 4/159 (2.5%), p = 0.001. The step-wise analysis identified 2 signatures increasing performances. Signature 1 combined a higher signal intensity than that of the cortex on T2WI and a CSA. Signature 2 included these two features and the presence of a single starting point of enhancement. Sensitivity, specificity, and accuracy were 0.83, 0.94, and 0.92 for signature 1 and 0.97, 0.93, and 0.93 for signature 2, respectively.
CONCLUSION: Structural MRI yields high sensitivity and specificity when diagnosing OCVM.
KEY POINTS: • Structural MRI shows high sensitivity and specificity when diagnosing orbital cavernous venous malformation. • We identified two signatures combining structural MRI features which might be used easily in routine clinical practice. • The combination of higher signal intensity of the lesion as compared to the cortex on T2WI and of a chemical shift artifact yields a sensitivity and specificity of 0.83 and 0.94 for the diagnosis of orbital cavernous venous malformation, respectively.
引用
- Elbaze S, Duron L, Mambour N, et al. A signature of structural MRI features at 3 Tesla allows an accurate characterization of orbital cavernous venous malformation. Eur Radiol. 2022. PMID: 36264311. doi:10.1007/s00330-022-09163-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。