文献速递神经儿科影像MR

儿童后颅窝肿瘤手术中的动脉自旋标记灌注指标

Arterial Spin-Labeling Perfusion Metrics in Pediatric Posterior Fossa Tumor Surgery.
PubMed 文献 · AJNR Am J Neuroradiol · 2022-09-22

研究对44例儿童后颅窝肿瘤患者在前、术后及3个月随访时进行多流入时间动脉自旋标记扫描,发现肿瘤切除后脑血流量升高、达峰时间缩短;术前需脑脊液分流的有症状梗阻性脑水患儿灌注变化更明显,术后发生小脑缄默综合征的8例患儿随访时脑血流量更高。

要点

  • 儿童后颅窝肿瘤切除后脑血流量升高、达峰时间缩短,随访仍维持此变化。
  • 术前需分流的有症状梗阻性脑水患儿基线平均脑血流量降低20.5 mL/100g/min。
  • 术后发生小脑缄默综合征者随访时脑血流量显著高于未发生者。

核心结论

  • 多流入时间动脉自旋标记有潜力作为无创工具评估儿童梗阻性脑水时的脑灌注,并显示小脑缄默综合征缓解后脑血流量升高。

研究设计与样本

  • 前瞻性研究,44例患儿,在术前、术后及3个月随访三个时间点行单流入时间和多流入时间动脉自旋标记序列扫描,采用配准解剖分区进行区域脑血流量和达峰时间分析,使用方差分析和多变量线性混合效应模型,研究注册于clinicaltrials.gov(NCT03471026)。

诊断标准与关键数值

  • 肿瘤切除后及随访扫描时脑血流量升高(P = .045)。
  • 肿瘤切除后及随访扫描时达峰时间缩短(P = .018)。
  • 与后颅窝肿瘤的小脑半球手术入路相比,中线入路后达峰时间延长(P = .058)。
  • 6例术前需脑脊液分流的有症状梗阻性脑水患儿区域灌注变化更明显,脑水使基线平均脑血流量降低20.5(标准误6.27)mL/100g/min。
  • 8/44(18.2%)诊断小脑缄默综合征的患儿随访时脑血流量显著高于未发生者(P = .040),术前和术后灌注参数无差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Pediatric posterior fossa tumors often present with hydrocephalus; postoperatively, up to 25% of patients develop cerebellar mutism syndrome. Arterial spin-labeling is a noninvasive means of quantifying CBF and bolus arrival time. The aim of this study was to investigate how changes in perfusion metrics in children with posterior fossa tumors are modulated by cerebellar mutism syndrome and hydrocephalus requiring pre-resection CSF diversion.

MATERIALS AND METHODS: Forty-four patients were prospectively scanned at 3 time points (preoperatively, postoperatively, and at 3-month follow-up) with single- and multi-inflow time arterial spin-labeling sequences. Regional analyses of CBF and bolus arrival time were conducted using coregistered anatomic parcellations. ANOVA and multivariable, linear mixed-effects modeling analysis approaches were used. The study was registered at clinicaltrials.gov (NCT03471026).

RESULTS: CBF increased after tumor resection and at follow-up scanning (P = .045). Bolus arrival time decreased after tumor resection and at follow-up scanning (P = .018). Bolus arrival time was prolonged (P = .058) following the midline approach, compared with cerebellar hemispheric surgical approaches to posterior fossa tumors. Multivariable linear mixed-effects modeling showed that regional perfusion changes were more pronounced in the 6 children who presented with symptomatic obstructive hydrocephalus requiring pre-resection CSF diversion, with hydrocephalus lowering the baseline mean CBF by 20.5 (standard error, 6.27) mL/100g/min. Children diagnosed with cerebellar mutism syndrome (8/44, 18.2%) had significantly higher CBF at follow-up imaging than those who were not (P = .040), but no differences in pre- or postoperative perfusion parameters were seen.

CONCLUSIONS: Multi-inflow time arterial spin-labeling shows promise as a noninvasive tool to evaluate cerebral perfusion in the setting of pediatric obstructive hydrocephalus and demonstrates increased CBF following resolution of cerebellar mutism syndrome.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Toescu SM, Hales PW, Cooper J, et al. Arterial Spin-Labeling Perfusion Metrics in Pediatric Posterior Fossa Tumor Surgery. AJNR Am J Neuroradiol. 2022. PMID: 36137658. doi:10.3174/ajnr.A7637

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。