文献速递头颈外周血管MRCT

7 T超高场磁共振飞行时间血管成像在骨肌皮瓣术前评估腓骨穿支动脉中的应用

Time-of-Flight Angiography in Ultra-High-Field 7 T MRI for the Evaluation of Peroneal Perforator Arteries Before Osseomyocutaneous Flap Surgery.
PubMed 文献 · Invest Radiol · 2022-09-13

前瞻性研究纳入10例患者,术前用7 T磁共振飞行时间血管成像与双能CTA评估腓骨穿支动脉,以40 keV虚拟单能重建为标准。TOF显示图像质量更优,能更常对穿支亚型进行具体分类(53 vs 39,P<0.05),穿支显示长度更长(50±11 mm vs 40±9 mm,P=0.001),并在60%病例中改变了口腔颌面外科医生的术前穿支选择决策。

要点

  • 7 T TOF血管成像可术前评估腓骨穿支动脉,图像质量优于双能CTA(两位读者均P<0.05)。
  • TOF对穿支亚型的具体分类例数多于CTA(53 vs 39,P<0.05),穿支显示长度更长(50±11 mm vs 40±9 mm,P=0.001)。
  • TOF使口腔颌面外科医生在60%病例中改变了术前所选穿支的最终决策。

核心结论

  • 7 T磁共振TOF血管成像用于腓骨穿支动脉术前评估是可行的,且在穿支分类与识别方面优于CTA,可能有助于重建手术规划。

研究设计与样本

  • 前瞻性研究,纳入10例患者(平均年龄59.9±14.9岁,7例男性),2019年7月至2020年2月术前采集双小腿TOF血管成像与CTA。

关键影像表现/征象

  • TOF血管成像采用专用28通道膝关节线圈,采集时间9分55秒,体素0.4×0.4×0.8 mm。
  • CTA采用第三代双源CT于同日采集,以40 keV光子能量虚拟单能重建作为穿支动脉识别与分型的参考标准。
  • 两位独立读者评估图像质量、数量、长度及按手术考量对穿支动脉分类,TOF图像质量优于CTA(两位读者均P<0.05)。

诊断标准与关键数值

  • TOF与CTA分别识别53条与51条腓骨穿支动脉。
  • TOF对穿支亚型进行具体分类的例数多于CTA(53 vs 39,P<0.05)。
  • 两位读者对所有患者的TOF诊断信心均高于CTA(读者间一致性κ=0.8,P<0.05)。
  • 穿支长度测量TOF为50±11 mm,CTA为40±9 mm(P=0.001)。

临床应用与阅片要点

  • TOF与CTA均用于术前皮瓣设计并由口腔颌面外科医生评估。
  • 与CTA相比,TOF使口腔颌面外科医生在60%病例中改变了术前所选穿支动脉的最终决策。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Presurgical identification and morphologic characterization of the peroneal perforator arteries (PPAs) are essential for osseomyocutaneous flap surgery. The aim of this study was to evaluate PPAs using time-of-flight (TOF) angiography in 7 T magnetic resonance imaging in comparison with dual-energy computed tomographic angiography (CTA).

MATERIALS AND METHODS: In this prospective study, TOF angiography and CTA of both lower legs were acquired before flap surgery from 07/2019 to 02/2020. Magnetic resonance imaging was performed using a dedicated 28-channel knee coil with an acquisition time of 9:55 minutes (voxel size: 0.4 × 0.4 × 0.8 mm). Computed tomographic angiography was acquired with a third-generation dual-source computed tomography on the same day. Virtual monoenergetic reconstructions at 40 keV photon energy served as the standard of reference for PPA identification and subtyping. Two independent readers assessed the image quality, quantity, length assessment, and classification according to surgical considerations of PPAs for TOF angiography and CTA. Both TOF angiography and CTA were used for presurgical flap design and were evaluated by an orofacial surgeon.

RESULTS: Ten patients (mean age, 59.9 ± 14.9 years; 7 men) were included. Time-of-flight angiography and CTA identified 53 and 51 PPAs in total, respectively. Time-of-flight angiography showed superior image quality (both readers, P < 0.05). Time-of-flight angiography enabled specific classification of PPA subtypes more often (53 vs 39; P < 0.05), and both readers reported higher diagnostic confidence for TOF angiography than CTA in all patients (interrater agreement κ = 0.8; P < 0.05). Regarding length assessment, PPAs were significantly more conspicuous with TOF angiography (TOF mean , 50 ± 11 mm; CTA mean , 40 ± 9 mm; P = 0.001). In comparison with CTA, TOF angiography prospectively changed the orofacial surgeon's final decision on the presurgical selected PPAs in 60% of cases.

CONCLUSIONS: Presurgical assessment of PPAs is feasible using TOF in 7 T magnetic resonance imaging. Moreover, TOF angiography was superior to CTA for classifying and identifying PPAs, which may facilitate the planning of reconstructive surgery.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Wiesmueller M, Meixner CR, Weber M, et al. Time-of-Flight Angiography in Ultra-High-Field 7 T MRI for the Evaluation of Peroneal Perforator Arteries Before Osseomyocutaneous Flap Surgery. Invest Radiol. 2022. PMID: 36165876. doi:10.1097/RLI.0000000000000926

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。