钆塞酸增强肝脏MRI多动脉期采集在高危患者中检出富血供肝细胞癌:压缩感知与视图共享技术的比较
回顾性纳入385例高危肝细胞癌患者,比较压缩感知(CS,224例)与视图共享(VS,161例)技术在钆塞酸增强MRI单次屏气多动脉期成像中的图像质量和病灶检出率;CS组最佳时机晚动脉期无短暂严重运动伪影的获取率更高(82.1% vs 71.4%,P=0.013),整体图像质量更优(3.42±0.70 vs 2.97±0.61,P<0.001),对富强化病灶的检出可发现度无显著差异(0.660 vs 0.665,P=0.890),但对LR-M病灶检出率更高(100.0% vs 44.4%,P=0.009)。
要点
- CS技术较VS显著提高最佳时机晚动脉期无短暂严重运动伪影的获取率(82.1% vs 71.4%)。
- CS技术整体图像质量评分显著优于VS(3.42±0.70 vs 2.97±0.61)。
- CS对LR-M病灶检出率显著高于VS(100.0% vs 44.4%),富强化病灶检出可发现度无显著差异。
核心结论
- 在高危HCC患者中,CS技术似乎更易获得无短暂严重运动伪影的最佳时机晚动脉期,且对LR-M病灶的检出率高于VS技术。
研究设计与样本
- 回顾性纳入385例行钆塞酸增强MRI(含三动脉期,CS组224例、VS组161例)的高危HCC患者,其中117例有171个局灶性肝脏病灶(中位直径1.3 cm),按LI-RADS v2018分类;由3名放射科医生以4分法评价图像质量和病灶显示度,采用jackknife替代自由响应受试者工作特征方法比较检出可发现度。
诊断标准与关键数值
- CS组最佳时机晚动脉期无短暂严重运动伪影的获取率为82.1%(184/224),VS组为71.4%(115/161),P=0.013;CS组整体图像质量评分为3.42±0.70,VS组为2.97±0.61,P<0.001;富强化病灶检出的品质因数CS组为0.660,VS组为0.665,P=0.890;LR-M病灶检出率CS组为100.0%(9/9),VS组为44.4%(8/18),P=0.009。
临床应用与阅片要点
- 作者认为,在高危HCC患者的钆塞酸增强MRI中,CS技术似乎更易获得最佳时机晚动脉期且无短暂严重运动伪影,对LR-M病灶的检出率高于VS技术。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to compare compressed sensing (CS) and view sharing (VS) techniques for single breath-hold multiarterial phase imaging with respect to image quality and focal liver observation detectability during gadoxetic acid-enhanced magnetic resonance imaging in patients at high risk for hepatocellular carcinoma (HCC).
MATERIALS AND METHODS: A total of 385 patients who underwent gadoxetic acid-enhanced magnetic resonance imaging, including triple arterial phases using either CS (n = 224) or VS (n = 161) techniques, were retrospectively included. Among them, 117 patients had 171 focal liver observations (median diameter, 1.3 cm), which were classified according to Liver Imaging Reporting and Data System version 2018. The acquisition rate of optimally timed late arterial phase (LAP) was assessed, and image quality, including respiratory motion artifact and observation conspicuity, was rated on a 4-point scale by 3 radiologists. The Mann-Whitney U test and nonparametric test for repeated measures data were used for image quality and observation conspicuity analysis. The jackknife alternative free-response receiver operating characteristics method was used to compare the observation detectability between the 2 techniques.
RESULTS: The CS technique showed significantly higher acquisition rate of optimally timed LAP without transient severe motion (82.1% [184/224] vs 71.4% [115/161]; P = 0.013) than the VS technique. The CS technique also demonstrated significantly improved overall image quality (3.42 ± 0.70 vs 2.97 ± 0.61; P < 0.001) compared with the VS technique. Regarding the detection of hyperenhancing observations, there was no significant difference between the figure of merits of CS and VS techniques (0.660 vs 0.665; P = 0.890). However, the CS technique showed a higher detection rate in Liver Imaging Reporting and Data System M (LR-M, probably or definitely malignant but not HCC specific) observations than the VS technique (100.0% [9/9] vs 44.4% [8/18]; P = 0.009).
CONCLUSION: The CS technique tended to provide optimally timed LAP without transient severe motion and demonstrated greater detection rate of LR-M observations than the VS technique in patients at high risk of HCC.
引用
- Kim JH, Yoon JH, Bae JS, et al. Multiarterial Phase Acquisition in Gadoxetic Acid-Enhanced Liver MRI for the Detection of Hypervascular Hepatocellular Carcinoma in High-Risk Patients: Comparison of Compressed Sensing Versus View Sharing Techniques. Invest Radiol. 2022. PMID: 35976759. doi:10.1097/RLI.0000000000000910
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。