文献速递腹部泌尿生殖CT

多层螺旋CT能否准确鉴别弥漫性腹膜病变的良恶性病因

Is MDCT an accurate tool to differentiate between benign and malignant etiology in diffuse peritoneal disease?
PubMed 文献 · Abdom Radiol (NY) · 2022-08-17

回顾136例弥漫性腹膜病变患者,以网膜活检病理为金标准,评估腹部增强MDCT鉴别良恶性病因的效能。两名观察者诊断准确率分别为79.3%和86.7%,敏感度79.2%和74.6%,特异度79.4%和97%,Kappa 0.713;多项CT参数可区分结核性腹膜炎与腹膜癌病。

要点

  • 网膜厚度增加、网膜饼、>10mm结节、脏器扇贝样压迹、游离腹水、浆膜受累及双侧胸腔积液与恶性病因相关。
  • 肠系膜增厚/条索影、肠系膜淋巴结增大、坏死淋巴结、脾大及腹水CT值>20HU与良性病因相关。
  • 肠系膜增厚/条索影、脾大、腹水CT值>20HU、肠系膜淋巴结增大及坏死淋巴结更支持结核。

核心结论

  • 增强MDCT鉴别弥漫性腹膜病变良恶性病因具有较好的敏感度、特异度和准确率,多项常见CT参数可用于区分结核性腹膜炎与腹膜癌病。

研究设计与样本

  • 研究纳入136例弥漫性腹膜病变且后续行网膜活检的患者,以组织病理学为金标准,由两名观察者评估腹部CT上腹膜、肠系膜及网膜受累情况。

关键影像表现/征象

  • 高龄、网膜厚度增加(均值25.2mm)、网膜饼、>10mm肠系膜/腹膜结节、脏器扇贝样压迹、游离腹水、浆膜受累及双侧胸腔积液与恶性病因相关。
  • 肠系膜增厚/条索影、肠系膜淋巴结增大、坏死淋巴结、脾大及腹水CT值>20HU与良性病因相关。
  • 肠系膜增厚或条索影、脾大、腹水CT值>20HU、肠系膜淋巴结增大及坏死淋巴结更支持结核。

诊断标准与关键数值

  • 观察者1诊断准确率79.3%、敏感度79.2%、特异度79.4%;观察者2诊断准确率86.7%、敏感度74.6%、特异度97%;两名观察者间Kappa 0.713。
  • 网膜厚度均值25.2mm与恶性病因相关(p=0.004)。
  • 腹水CT值>20HU与良性病因相关(p<0.001),并更支持结核(p<0.01)。

临床应用与阅片要点

  • 阅片时应系统评估网膜厚度、网膜饼、结节大小、脏器扇贝样压迹、腹水及胸膜改变,以辅助良恶性鉴别。
  • 肠系膜增厚/条索影、肠系膜淋巴结增大及坏死淋巴结、脾大和腹水CT值>20HU提示良性病因,尤其需考虑结核。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: There is often considerable overlap of imaging findings in benign and malignant peritoneal diseases. We evaluated patients with diffuse peritoneal disease, to assess the diagnostic value of MDCT in predicting benign or malignant etiology in patients with unknown etiology, by analyzing the various patterns of involvement, particularly tuberculosis (TB) vs malignancy.

METHODS: One hundred and thirty-six patients with diffuse peritoneal disease who had abdominal CT and subsequently underwent omental biopsies were included in the study. Peritoneal, mesenteric and omental involvement by disease was evaluated on CT using specific parameters. The presence of lymphadenopathy, ascites, scalloping of organs, involvement of liver and spleen, were also compared between benign and malignant conditions using histopathology as the gold standard.

RESULTS: In 136 patients, 72 benign and 64 malignant pathologies were classified as per histopathology. Higher age (p < 0.001), increasing omental thickness (mean 25.2 mm, p = 0.004), omental caking (p < 0.001), > 10 mm mesenteric/peritoneal nodules (p < 0.03), visceral scalloping (p = 0.001), free ascites (p = 0.003), serosal involvement (p = 0.004) and bilateral pleural effusion (p = 0.02) were associated with malignant etiology. Mesenteric thickening/stranding (p = 0.02), mesenteric adenopathy (p < 0.001), necrotic nodes (p = 0.02), splenomegaly (p = < 0.001) and higher attenuation (> 20HU) of ascitic fluid (p < 0.001) were associated with benign etiology. The presence of mesenteric thickening or stranding (p = 0.01), splenomegaly (p = 0.02), higher ascitic fluid attenuation > 20HU (p = < 0.01), mesenteric adenopathy (p < 0.01), necrotic nodes (p = 0.03) favored tuberculosis. CT had diagnostic accuracy (79.3, 86.7%), sensitivity (79.2, 74.6%) and specificity (79.4, 97%) for observers 1 and 2, respectively (Kappa 0.713).

CONCLUSION: Contrast-enhanced MDCT has good sensitivity, specificity and accuracy in differentiating benign and malignant etiologies of diffuse peritoneal disease. Multiple common parameters can be used to differentiate between tuberculous peritonitis and peritoneal carcinomatosis.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. George S, Sathyakumar K, Bindra MS, et al. Is MDCT an accurate tool to differentiate between benign and malignant etiology in diffuse peritoneal disease? Abdom Radiol (NY). 2022. PMID: 35978185. doi:10.1007/s00261-022-03641-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。