文献速递神经MR

基于深度学习重建的去噪方法在快速FLAIR成像上量化多发性硬化病灶负荷的验证

Validation of a Denoising Method Using Deep Learning-Based Reconstruction to Quantify Multiple Sclerosis Lesion Load on Fast FLAIR Imaging.
PubMed 文献 · AJNR Am J Neuroradiol · 2022-07-28

前瞻性纳入28例多发性硬化患者,比较4种不同扫描时间的3D-FLAIR序列(4分54秒至1分15秒)在有无基于深度学习重建去噪时的图像质量与病灶分割性能。结果显示加速扫描时图像质量与定量指标均下降,但去噪能显著改善主观图像质量和定量性能,尤其对手动分割;2分35秒去噪序列与4分54秒参考序列的Dice相似系数相当。

要点

  • 加速FLAIR扫描会降低图像质量和病灶定量准确性,但深度学习去噪可部分恢复。
  • 2分35秒去噪FLAIR与4分54秒参考FLAIR的Dice相似系数相当。
  • 去噪有助于识别原本被噪声掩盖的多发性硬化病灶。

核心结论

  • 基于深度学习重建的去噪有助于识别加速FLAIR采集噪声中隐藏的多发性硬化病灶,可能是临床实践中有效缩短扫描时间的策略。

研究设计与样本

  • 前瞻性研究,纳入28例多发性硬化患者,采用4种递减扫描时间的3D-FLAIR序列(4分54秒、2分35秒、1分40秒、1分15秒),每种序列分别行无去噪和有去噪重建,共8个FLAIR序列/患者;以手动和自动病灶分割随机盲法对照金标准进行定量评估。

诊断标准与关键数值

  • 图像质量采用Likert量表、表观SNR和对比噪声比评估;病灶分割定量指标包括绝对体积差、真阳性率、阳性预测值、Dice相似系数、Hausdorff距离和基于病灶计数的F1评分;2分35秒去噪FLAIR与4分54秒参考FLAIR的Dice相似系数相当。

临床应用与阅片要点

  • 作者认为基于深度学习重建的去噪可能有助于识别加速FLAIR采集噪声中隐藏的多发性硬化病灶,并可能有效缩短临床实践中的扫描时间。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Accurate quantification of WM lesion load is essential for the care of patients with multiple sclerosis. We tested whether the combination of accelerated 3D-FLAIR and denoising using deep learning-based reconstruction could provide a relevant strategy while shortening the imaging examination.

MATERIALS AND METHODS: Twenty-eight patients with multiple sclerosis were prospectively examined using 4 implementations of 3D-FLAIR with decreasing scan times (4 minutes 54 seconds, 2 minutes 35 seconds, 1 minute 40 seconds, and 1 minute 15 seconds). Each FLAIR sequence was reconstructed without and with denoising using deep learning-based reconstruction, resulting in 8 FLAIR sequences per patient. Image quality was assessed with the Likert scale, apparent SNR, and contrast-to-noise ratio. Manual and automatic lesion segmentations, performed randomly and blindly, were quantitatively evaluated against ground truth using the absolute volume difference, true-positive rate, positive predictive value, Dice similarity coefficient, Hausdorff distance, and F1 score based on the lesion count. The Wilcoxon signed-rank test and 2-way ANOVA were performed.

RESULTS: Both image-quality evaluation and the various metrics showed deterioration when the FLAIR scan time was accelerated. However, denoising using deep learning-based reconstruction significantly improved subjective image quality and quantitative performance metrics, particularly for manual segmentation. Overall, denoising using deep learning-based reconstruction helped to recover contours closer to those from the criterion standard and to capture individual lesions otherwise overlooked. The Dice similarity coefficient was equivalent between the 2-minutes-35-seconds-long FLAIR with denoising using deep learning-based reconstruction and the 4-minutes-54-seconds-long reference FLAIR sequence.

CONCLUSIONS: Denoising using deep learning-based reconstruction helps to recognize multiple sclerosis lesions buried in the noise of accelerated FLAIR acquisitions, a possibly useful strategy to efficiently shorten the scan time in clinical practice.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Yamamoto T, Lacheret C, Fukutomi H, et al. Validation of a Denoising Method Using Deep Learning-Based Reconstruction to Quantify Multiple Sclerosis Lesion Load on Fast FLAIR Imaging. AJNR Am J Neuroradiol. 2022. PMID: 35902124. doi:10.3174/ajnr.A7589

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。