文献速递妇产影像US

超声引导下复位部分脱出宫内节育器的可行性描述性研究

Ultrasound-guided repositioning technique for partially expelled intrauterine device: descriptive feasibility study.
PubMed 文献 · Ultrasound Obstet Gynecol · 2023-01-01

这项描述性可行性研究纳入2016年1月至2020年2月门诊处理的55例部分脱出宫内节育器患者,在无镇静、无麻醉及预防性抗生素条件下,采用超声引导下Hartmann鳄嘴钳将节育器复位至宫底。复位成功率为92.7%(51/55),4例因疼痛未完成;成功复位的51例中6个月内9例(17.6%)再次脱出,6例失访,未发生子宫穿孔或感染相关并发症。作者认为该技术似乎是安全可行的。

要点

  • 超声引导下复位部分脱出宫内节育器成功率为92.7%(51/55)。
  • 复位过程未使用镇静、麻醉及预防性抗生素。
  • 成功复位的51例中6个月内9例(17.6%)再次脱出。

核心结论

  • 超声引导下复位技术似乎是处理部分脱出宫内节育器的安全可行方法。

研究设计与样本

  • 描述性可行性研究,纳入2016年1月至2020年2月在本门诊处理的55例部分脱出宫内节育器患者(35枚左炔诺孕酮节育器、20枚铜节育器),在超声引导下用Hartmann鳄嘴钳将节育器复位至宫底,未使用宫颈旁或宫颈内麻醉及预防性抗生素,数据来自病历记录及6个月随访。

关键影像表现/征象

  • 部分脱出定义为宫内节育器纵臂部分或完全穿过宫颈管。
  • 复位成功的判定标准为超声确认整个节育器位于宫颈内口以上。

诊断标准与关键数值

  • 复位成功率为92.7%(51/55),4例因疼痛未完成操作。
  • 55例操作中48例(87.3%)由妇产科受训医师在资深专家监督下完成。
  • 成功复位的51例中,6个月内9例(17.6%)节育器脱出,6例失访。
  • 操作后6个月内未发生子宫穿孔或感染相关并发症。

临床应用与阅片要点

  • 本研究中部分脱出宫内节育器的复位在超声引导下完成,未使用镇静、宫颈旁或宫颈内麻醉及预防性抗生素。
  • 复位成功的判定依据为超声确认整个节育器位于宫颈内口以上。
  • 作者认为该超声引导复位技术似乎是处理部分脱出宫内节育器的安全可行方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To describe the feasibility of an ultrasound-guided repositioning technique for partially expelled intrauterine devices (IUDs) without use of sedation.

METHODS: This was a descriptive feasibility study of patients with a partially expelled IUD managed in our outpatient clinic from January 2016 to February 2020. The partially expelled IUDs (vertical arm extending partially or entirely through the cervical canal) were repositioned at the uterine fundus using Hartmann alligator forceps under ultrasound guidance. Paracervical or intracervical anesthesia and prophylactic antibiotics were not used. Data related to the procedure and 6-month follow-up were extracted from patient medical records. The primary outcome was the success rate of the repositioning procedure, defined as ultrasound confirmation of the entire IUD located above the internal os. Secondary outcomes included the retention and expulsion rates of the repositioned IUD at 6 months after the procedure and description of complications.

RESULTS: We included data from 55 women with a partially expelled IUD (35 levonorgestrel IUDs and 20 copper IUDs) referred for repositioning. Ultrasound-guided repositioning of the IUD was successful in 51 (92.7%) cases, while the procedure was not completed in four patients due to pain. Of the 55 procedures, 48 (87.3%) were performed by obstetrics and gynecology trainees under the supervision of a senior specialist. Among the 51 successfully repositioned IUDs, nine (17.6%) were expelled within 6 months after the procedure and six patients were lost to follow-up. No uterine perforation or infection-related complications occurred within 6 months of the procedure.

CONCLUSION: The ultrasound-guided repositioning technique appears to be a safe and feasible approach for partially expelled IUDs. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Yamaguti EMM, Sontag Dos Reis ET, Martins WP, et al. Ultrasound-guided repositioning technique for partially expelled intrauterine device: descriptive feasibility study. Ultrasound Obstet Gynecol. 2023. PMID: 35793228. doi:10.1002/uog.26023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。