基于冠状动脉CT血管成像的冠状动脉介入虚拟规划器的临床验证
这项多中心前瞻性研究纳入120例慢性冠脉综合征患者(123支血管),以有创FFR≤0.80定义显著病变,验证FFRCT规划器预测PCI术后FFR的准确性。规划器预测术后FFR为0.86±0.06,实测为0.88±0.06,平均差0.02±0.07,一致性界限-0.12至0.15;以术后OCT为参考,规划器最小支架面积5.0±2.2 mm²,OCT为5.60±2.01 mm²。
要点
- FFRCT规划器预测PCI术后FFR与实测值平均差仅0.02±0.07 FFR单位,一致性界限-0.12至0.15。
- 规划器最小支架面积5.0±2.2 mm²,OCT参考值5.60±2.01 mm²,平均差0.66±1.21 mm²。
- 在局限性和弥漫性病变、低钙和高钙负荷病例中,规划器的准确性和精确度均保持较高水平。
核心结论
- 基于FFRCT的技术在预测PCI术后FFR方面准确且精确。
研究设计与样本
- 多中心、研究者发起的前瞻性研究,筛查259例,最终分析120例患者(123支血管),纳入慢性冠脉综合征且基于有创FFR≤0.80的显著病变患者;将FFRCT规划器应用于FFRCT模型模拟PCI,以术后有创FFR和术后OCT为参考标准。
诊断标准与关键数值
- 主要目标为FFRCT规划器预测的术后FFR与实测术后FFR的一致性:实测术后FFR 0.88±0.06,规划器FFR 0.86±0.06,平均差0.02±0.07 FFR单位,一致性界限-0.12至0.15。
- 以术后OCT为参考评估规划器管腔尺寸准确性:OCT最小支架面积5.60±2.01 mm²,规划器最小支架面积5.0±2.2 mm²,平均差0.66±1.21 mm²,一致性界限-1.7至3.0。
- 在局限性和弥漫性病变以及低钙和高钙负荷病例中,规划器的准确性和精确度均保持较高水平。
临床应用与阅片要点
- FFRCT规划器可在PCI术前基于冠状动脉CTA模拟PCI,预测术后FFR,可能有助于手术规划。
- 规划器预测的术后FFR与实测值一致性界限较宽(-0.12至0.15 FFR单位),阅片和报告时需注意个体预测值存在波动。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Low fractional flow reserve (FFR) values after percutaneous coronary intervention (PCI) carry a worse prognosis than high post-PCI FFR values. Therefore, the ability to predict post-PCI FFR might play an important role in procedural planning. Post-PCI FFR values can now be computed from pre-PCI coronary computed tomography angiography (CTA) using the fractional flow reserve derived from coronary computed tomography angiography revascularization planner (FFRCT Planner).
OBJECTIVES: The aim of this study was to validate the accuracy of the FFRCT Planner.
METHODS: In this multicenter, investigator-initiated, prospective study, patients with chronic coronary syndromes and significant lesions based on invasive FFR ≤0.80 were recruited. The FFRCT Planner was applied to the fractional flow reserve derived from coronary computed tomography angiography (FFRCT) model, simulating PCI. The primary objective was the agreement between the predicted post-PCI FFR by the FFRCT Planner and measured post-PCI FFR. Accuracy of the FFRCT Planner's luminal dimensions was assessed by using post-PCI optical coherence tomography as the reference.
RESULTS: Overall, 259 patients were screened, with 120 patients (123 vessels) included in the final analysis. The mean patient age was 64 ± 9 years, and 24% had diabetes. Measured FFR post-PCI was 0.88 ± 0.06, and the FFRCT Planner FFR was 0.86 ± 0.06 (mean difference: 0.02 ± 0.07 FFR unit; limits of agreement: -0.12 to 0.15). Optical coherence tomography minimal stent area was 5.60 ± 2.01 mm2, and FFRCT Planner minimal stent area was 5.0 ± 2.2 mm2 (mean difference: 0.66 ± 1.21 mm2; limits of agreement: -1.7 to 3.0). The accuracy and precision of the FFRCT Planner remained high in cases with focal and diffuse disease and with low and high calcium burden.
CONCLUSIONS: The FFRCT-based technology was accurate and precise for predicting FFR after PCI. (Precise Percutaneous Coronary Intervention Plan Study [P3]; NCT03782688).
引用
- Sonck J, Nagumo S, Norgaard BL, et al. Clinical Validation of a Virtual Planner for Coronary Interventions Based on Coronary CT Angiography. JACC Cardiovasc Imaging. 2022. PMID: 35798401. doi:10.1016/j.jcmg.2022.02.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。