前瞻性术前3-T MR神经成像对植入FAST-LIFE电极接口机械手的上肢截肢患者进行周围神经映射的技术报告
前瞻性初步研究纳入5例上肢截肢患者,术前行3-T MR神经成像、X线和电生理检查,MR神经成像显示正中神经和尺神经残端神经瘤及扩散特性改变,即使电生理无异常也能为FAST-LIFE接口术前规划提供解剖信息。
要点
- 3-T MR神经成像可清晰显示前臂和手部神经解剖及神经瘤,用于FAST-LIFE接口术前规划。
- 正中神经和尺神经残端神经瘤中位大小分别约10.5 mm和9.75 mm,ADC值升高。
- 电生理检查2/5无异常,但MR神经成像仍能显示神经瘤和扩散改变。
核心结论
- 3-T MR神经成像能极好地展示前臂和手部神经解剖、扩散特性改变及神经瘤,即使电生理无异常,也可用于FAST-LIFE(机械手)接口的术前规划。
研究设计与样本
- 前瞻性初步研究技术报告,纳入5例上肢截肢患者(年龄21-59岁),术前接受3-T MR神经成像、X线和电生理检查,MR神经成像表现与电生理报告相关联,采用描述性统计。
关键影像表现/征象
- X线显示3/5例为部分手截肢,2/5例为经桡骨截肢。
- 正中神经和尺神经残端球状神经瘤分别测量为10.1 ± 3.04 mm(范围5.5-14 mm,中位数10.5 mm)和10.9 ± 7.64 mm(范围2-22 mm,中位数9.75 mm)。
- 正中神经和尺神经ADC值分别升高至1.64 ± 0.1 × 10-3 mm2/s(范围1.5-1.8,中位数1.64 × 10-3 mm2/s)和1.70 ± 0.17 × 10-3 mm2/s(范围1.49-1.98 × 10-3 mm2/s,中位数1.65 × 10-3 mm2/s)。
- 其他识别的病变包括桡神经浅支和前骨间神经的神经瘤。
临床应用与阅片要点
- 电生理检查2/5报告无异常,2/5显示正中神经和尺神经混合运动感觉神经病伴桡神经感觉神经病,1/5显示前臂外侧皮神经感觉神经病。
- 所有患者均恢复了自然感觉和手指运动控制。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Fascicular targeting of longitudinal intrafascicular electrode (FAST-LIFE) interface enables hand dexterity with exogenous electrical microstimulation for sensory restoration, custom neural recording hardware, and deep learning-based artificial intelligence for motor intent decoding. The purpose of this technical report from a prospective pilot study was to illustrate magnetic resonance neurography (MRN) mapping of hand and nerve anatomy in amputees and incremental value of MRN over electrophysiology findings in pre-surgical planning of FAST-LIFE interface (robotic hand) patients.
MATERIALS AND METHODS: After obtaining informed consent, patients with upper extremity amputations underwent pre-operative 3-T MRN, X-rays, and electrophysiology. MRN findings were correlated with electrophysiology reports. Descriptive statistics were performed.
RESULTS: Five patients of ages 21-59 years exhibited 3/5 partial hand amputations, and 2/5 transradial amputations on X-rays. The median and ulnar nerve end bulb neuromas measured 10.1 ± 3.04 mm (range: 5.5-14 mm, median: 10.5 mm) and 10.9 ± 7.64 mm (2-22 mm, 9.75 mm), respectively. The ADC of median and ulnar nerves were increased at 1.64 ± 0.1 × 10-3 mm2/s (range: 1.5-1.8, median: 1.64 × 10-3 mm2/s) and 1.70 ± 0.17 × 10-3 mm2/s (1.49-1.98 × 10-3 mm2/s, 1.65 × 10-3 mm2/s), respectively. Other identified lesions were neuromas of superficial branch of the radial nerve and anterior interosseous nerve. On electrophysiology, 2/5 reports were unremarkable, 2/5 showed mixed motor-sensory neuropathies of median and ulnar nerves along with radial sensory neuropathy, and 1/5 showed sensory neuropathy of lateral cutaneous nerve of the forearm. All patients regained naturalistic sensations and motor control of digits.
CONCLUSION: 3-T MRN allows excellent demonstration of forearm and hand nerve anatomy, altered diffusion characteristics, and their neuromas despite unremarkable electrophysiology for pre-surgical planning of the FAST-LIFE (robotic hand) interfaces.
引用
- Mogharrabi B, Cheng J, Ratakonda R, et al. Prospective pre-operative 3-T MR neurography peripheral nerve mapping of upper extremity amputations implanted with FAST-LIFE electrode interfaces of robotic hands: technical report. Skeletal Radiol. 2022. PMID: 35635556. doi:10.1007/s00256-022-04079-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。