胫骨结节-Roman弓(TT-RA)距离在评估膝骨关节炎患者冠状面力线不良时优于胫骨结节-滑车沟(TT-TG)距离
本研究纳入2016至2020年膝骨关节炎患者,按膝外翻与膝内翻分组并进行1:1匹配,在CT或X线图像上测量TT-TG距离、TT-RA距离、髌骨高度、髌骨倾斜、髋-膝-踝(HKA)角及Iwano髌股骨关节炎(PFOA)分级。结果显示TT-TG距离的观察者间与观察者内信度随PFOA程度增加而下降(ICC<0.75),而TT-RA距离在Iwano分级各期均呈优良一致性;膝外翻力线不良与重度PFOA是病理性TT-RA距离的显著危险因素。
要点
- TT-TG距离的信度随PFOA加重而下降(ICC<0.75),TT-RA距离在Iwano各期信度均优良。
- 膝外翻患者中HKA角与TT-TG距离(r=0.34,p=0.003)及TT-RA距离(r=0.39,p=0.001)均呈弱相关。
- 膝外翻力线不良与重度PFOA是病理性TT-RA距离的危险因素,OR分别为3.26与3.10。
核心结论
- 在膝骨关节炎患者中,TT-RA距离比TT-TG距离更可靠;膝外翻力线不良和重度PFOA是病理性TT-RA距离的危险因素。
研究设计与样本
- 研究纳入2016至2020年膝骨关节炎患者,分为膝外翻组与膝内翻组并进行1:1匹配,每组75膝,通过CT图像或X线片测量TT-TG距离、TT-RA距离、髌骨高度、髌骨倾斜、HKA角及Iwano PFOA分级。
关键影像表现/征象
- TT-TG距离的观察者间与观察者内信度随PFOA程度增加而下降(ICC<0.75)。
- TT-RA距离在Iwano分级不同分期间均显示优良一致性。
- 膝外翻膝中HKA角与TT-TG距离呈弱相关(r=0.34,p=0.003),与TT-RA距离亦呈弱相关(r=0.39,p=0.001)。
- HKA角每增加1度,TT-TG距离与TT-RA距离分别增加近0.45 mm与0.61 mm。
诊断标准与关键数值
- 膝外翻力线不良与病理性TT-RA距离显著相关,OR为3.26(95% CI [1.06-10.03],p=0.036)。
- 重度PFOA与病理性TT-RA距离显著相关,OR为3.10(95% CI [1.01-9.54],p=0.048)。
- TT-TG距离在PFOA程度增加时信度下降(ICC<0.75),TT-RA距离在Iwano各期信度优良。
临床应用与阅片要点
- 在评估膝骨关节炎患者冠状面力线不良时,TT-RA距离是TT-TG距离的可靠且可重复的替代指标,尤其适用于重度PFOA患者。
- 膝外翻力线不良或重度PFOA患者中,胫骨结节病理性外侧化更易被追踪,可能参与髌股关节力线不良。
- 膝外翻膝中TT-TG距离或TT-RA距离与HKA角存在显著关系,而膝内翻膝中这些参数间相关性不显著。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To verify tibial tubercle-Roman arch (TT-RA) distance is superior to tibial tubercle-trochlear groove (TT-TG) distance in preoperative assessment of patellofemoral joints in patients with knee osteoarthritis.
METHODS: Patients with knee osteoarthritis from 2016 to 2020 were considered eligible for inclusion in this study. We divided the patients into valgus group and varus group and did 1:1 matching for the two groups. We measured the TT-TG distance, TT-RA distance, patellar height, patella tilt, hip-knee-ankle (HKA) angle, and Iwano's classification of patellofemoral osteoarthritis (PFOA) by computed tomography images or radiographs. The intraclass correlation coefficient (ICC) of each measurement, the correlations and differences among the parameters, and binary logistic regression analysis were conducted.
RESULTS: Each group in this study included 75 knees. The inter-observer and intra-observer reliability of the TT-TG distance decreased with the increasing degree of PFOA (ICC < 0.75). The reliability of the TT-RA distance showed excellent agreement in different stages of Iwano's classification. The HKA angle was poorly correlated with the TT-TG distance (r = 0.34, p = 0.003) and the TT-RA distance (r = 0.39, p = 0.001) in valgus knees. As the HKA angle increased by 1 degree, the TT-TG and TT-RA distance increased by nearly 0.45 mm and 0.61 mm, respectively. Valgus malalignment and severe PFOA revealed significant ORs of 3.26 (95% CI [1.06-10.03], p = 0.036) and 3.10 (95% CI [1.01-9.54], p = 0.048) with regard to pathological TT-RA distance, respectively.
CONCLUSION: The TT-RA distance was more reliable than the TT-TG distance in patients with knee osteoarthritis. Valgus malalignment and severe PFOA were risk factors for pathological TT-RA distance.
KEY POINTS: • The TT-RA distance is a reliable and repeatable alternative to the TT-TG distance in evaluating coronal malalignment, especially in patients with severe PFOA. • We validated the significant relationships between TT-TG distance or TT-RA distance and HKA angle in valgus knees, while the correlations among such parameters were not significant in varus knees. • Pathological lateralization of the tibial tubercle was prone to be traced in patients with valgus malalignment or severe PFOA, which could contribute to the patellofemoral malalignment.
引用
- Chen J, Li X, Xu Z, et al. Tibial tubercle-Roman arch (TT-RA) distance is superior to tibial tubercle-trochlear groove (TT-TG) distance when evaluating coronal malalignment in patients with knee osteoarthritis. Eur Radiol. 2022. PMID: 35729426. doi:10.1007/s00330-022-08924-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。