文献速递腹部技术与安全US

剪切波弹性成像联合剪切波频散成像在肝肿瘤患者术前肝实质评估中的临床应用

Clinical Application of Shear Wave Elastography With Shear Wave Dispersion Imaging in the Preoperative Evaluation of Hepatic Parenchyma in Patients With Liver Tumors.
PubMed 文献 · J Ultrasound Med · 2022-06-22

该前瞻性研究纳入174例肝肿瘤患者,术前用剪切波弹性成像(SWE)和剪切波频散成像(SWD)评估肝实质,以Scheuer标准病理分期为参考。SWE和SWD值与肝纤维化分期均高度相关(P<.05),与坏死性炎症活动度中度相关(P<.05),与脂肪变性不相关(P>.05)。SWE预测重度纤维化(S≥3)和肝硬化(S=4)的准确性高于SWD。

要点

  • SWE预测S≥1、S≥2、S≥3、S=4的AUC分别为0.982、0.977、0.969、0.984,最佳截断值分别为6.9、7.9、8.7、10.6 kPa。
  • SWD预测S≥1、S≥2、S≥3、S=4的AUC分别为0.967、0.960、0.925、0.954,最佳截断值分别为11.2、12.0、13.2、16.0 m/s/kHz。
  • SWE预测重度纤维化(S≥3)和肝硬化(S=4)的准确性高于SWD。

核心结论

  • SWE和SWD均可无创、准确地预测肝肿瘤患者术前肝纤维化分期,SWE预测重度纤维化(S≥3)和肝硬化(S=4)的准确性高于SWD。

研究设计与样本

  • 前瞻性研究,纳入174例肝肿瘤患者,术前行SWE和SWD检查,以Scheuer标准组织病理学确定的纤维化分期和坏死性炎症活动度为参考标准,比较SWE与SWD的诊断准确性。

关键影像表现/征象

  • SWE和SWD值与肝纤维化分期均高度相关(P<.05)。
  • SWE和SWD值与坏死性炎症活动度均中度相关(P<.05)。
  • SWE和SWD值与脂肪变性均不相关(P>.05)。
  • 不同肝纤维化分期患者的SWE和SWD值差异均有统计学意义(P<.001)。

诊断标准与关键数值

  • SWE预测S≥1、S≥2、S≥3、S=4的AUC分别为0.982、0.977、0.969、0.984,最佳截断值分别为6.9、7.9、8.7、10.6 kPa。
  • SWD预测S≥1、S≥2、S≥3、S=4的AUC分别为0.967、0.960、0.925、0.954,最佳截断值分别为11.2、12.0、13.2、16.0 m/s/kHz。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to compare the diagnostic accuracy of shear wave elastography (SWE) with that of shear wave dispersion (SWD) in evaluation of hepatic parenchyma in patients with liver tumors before resection.

METHODS: A total of 174 patients with liver tumors were prospectively enrolled. SWE and SWD examinations were performed. Fibrosis stage and necroinflammatory activity were determined histopathologically according to the Scheuer standard. We compared the diagnostic accuracy of SWE and SWD.

RESULTS: Both SWE and SWD values of the liver were highly correlated with liver fibrosis stage (P < .05, respectively). Both SWE and SWD values of the liver were moderately correlated with necroinflammatory activity (P < .05, respectively). Both SWE and SWD values of the liver were not correlated with steatosis (P > .05, respectively). Both SWE and SWD values were significantly different among the patients with different stages of liver fibrosis (P < .001, respectively). The area under the receiver operating characteristic (ROC) curve of SWE value was 0.982, 0.977, 0.969, and 0.984 for predicting S ≥ 1, S ≥ 2, S ≥ 3, and S = 4, respectively. The optimal cutoff SWE values were 6.9, 7.9, 8.7, and 10.6 kPa for S ≥ 1, S ≥ 2, S ≥ 3, and S = 4, respectively. The area under the ROC curve of SWD value was 0.967, 0.960, 0.925, and 0.954 for predicting S ≥ 1, S ≥ 2, S ≥ 3, and S = 4, respectively. The optimal cutoff SWD values were 11.2, 12.0, 13.2, and 16.0 m/s/kHz for S ≥ 1, S ≥ 2, S ≥ 3, and S = 4, respectively.

CONCLUSIONS: SWE and SWD could be noninvasive and accurate for predicting the stage of liver fibrosis in patients with liver tumors before surgery. SWE was more accurate than SWD in predicting severe fibrosis (S ≥ 3) and cirrhosis (S = 4).

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Wang K, Zhang S, Zhou W, et al. Clinical Application of Shear Wave Elastography With Shear Wave Dispersion Imaging in the Preoperative Evaluation of Hepatic Parenchyma in Patients With Liver Tumors. J Ultrasound Med. 2022. PMID: 35730210. doi:10.1002/jum.16029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。