文献速递心血管CTDSA

广泛冠状动脉钙化稳定胸痛患者中FFRCT的诊断与临床价值:FACC研究

Diagnostic and Clinical Value of FFRCT in Stable Chest Pain Patients With Extensive Coronary Calcification: The FACC Study.
PubMed 文献 · JACC Cardiovasc Imaging · 2022-02-16

前瞻性多中心研究纳入260例疑似冠心病且Agatston评分>399的稳定患者,独立核心实验室盲法测量FFRCT,以有创冠状动脉造影和FFR为参考评估诊断准确性。共定位FFRCT诊断血流动力学显著冠心病的准确度71%、敏感度87%、特异度54%、AUC 0.75;采用患者最低FFRCT时准确度57%、敏感度95%、特异度32%、AUC 0.84。90天随访中FFRCT>0.80患者无主要临床事件。

要点

  • Agatston评分>399的稳定胸痛患者中,78%的患者FFRCT≤0.80。
  • 共定位FFRCT诊断血流动力学显著冠心病的AUC为0.75,敏感度87%、特异度54%。
  • 采用患者最低FFRCT时AUC为0.84,但特异度仅32%,敏感度95%。

核心结论

  • Agatston评分>399患者多数FFRCT≤0.80;以ICA/FFR为参考,共定位FFRCT诊断准确度中等,较患者最低FFRCT提高了准确度和特异度;90天随访良好,FFRCT>0.80患者无主要临床事件。

研究设计与样本

  • 前瞻性多中心研究,纳入260例疑似冠心病且Agatston评分>399的稳定患者,FFRCT由独立核心实验室盲法测量,所有患者接受有创冠状动脉造影及必要时FFR检查。

诊断标准与关键数值

  • FFRCT≤0.80为阳性阈值,与ICA/FFR定义的血流动力学显著冠心病(左主干≥50%或心外膜动脉≥70%狭窄和/或FFR≤0.80)进行一致性评估。
  • 共定位FFRCT(n=112)诊断血流动力学显著冠心病的准确度71%、敏感度87%、特异度54%,AUC为0.75。
  • 采用患者最低FFRCT(n=260)时,准确度57%、敏感度95%、特异度32%,AUC为0.84。

临床应用与阅片要点

  • 在Agatston评分>399的稳定胸痛患者中,共定位FFRCT较患者最低FFRCT测量提高了诊断准确度和特异度。
  • 85例接受血运重建的患者中,96% FFRCT≤0.80;随访期间3例(1.2%)发生主要临床事件,均FFRCT≤0.80。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The influence of extensive coronary calcifications on the diagnostic and prognostic value of coronary computed tomography angiography-derived fractional flow reserve (FFRCT) has been scantily investigated.

OBJECTIVES: The purpose of this study was to investigate the diagnostic and short-term role of FFRCT in chest pain patients with Agatston score (AS) >399.

METHODS: This was a prospective multicenter study of 260 stable patients with suspected coronary artery disease (CAD) and AS >399. FFRCT was measured blinded by an independent core laboratory. All patients underwent invasive coronary angiography (ICA) and FFR if indicated. The agreement of FFRCT ≤0.80 with hemodynamically significant CAD on ICA/FFR (≥50% left main or ≥70% epicardial artery stenosis and/or FFR ≤0.80) was assessed. Patients undergoing FFR had colocation FFRCT measured, and the lowest per-patient FFRCT was registered in all patients. The association among per-patient FFRCT, coronary revascularization, and major clinical events (all-cause mortality, myocardial infarction, or unstable angina hospitalization) at 90-day follow-up was evaluated.

RESULTS: Median age and AS were 68.5 years (IQR: 63-74 years) and 895 (IQR: 587-1,513), respectively. FFRCT was ≤0.80 in 204 patients (78%). Colocation FFRCT (n = 112) showed diagnostic accuracy, sensitivity, and specificity to identify hemodynamically significant CAD of 71%, 87%, and 54%. The area under the receiver-operating characteristics curve (AUC) was 0.75. When using the lowest FFRCT (n = 260), per-patient accuracy, sensitivity, and specificity were 57%, 95%, and 32%, respectively. The AUC was 0.84. A total of 85 patients underwent revascularization, and FFRCT was ≤0.80 in 96% of these. During follow-up, major clinical events occurred in 3 patients (1.2%), all with FFRCT ≤0.80.

CONCLUSIONS: Most patients with AS >399 had FFRCT ≤0.80. Using ICA/FFR as the reference revealed a moderate diagnostic accuracy of colocation FFRCT. Compared with the lowest per-patient FFRCT, colocation FFRCT measurement improved diagnostic accuracy and specificity. The 90-day follow-up was favorable with few coronary revascularizations and no major clinical events occurring in patients with FFRCT >0.80. (Use of FFR-CT in Stable Intermediate Chest Pain Patients With Severe Coronary Calcium Score [FACC]; NCT03548753).

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Mickley H, Veien KT, Gerke O, et al. Diagnostic and Clinical Value of FFRCT in Stable Chest Pain Patients With Extensive Coronary Calcification: The FACC Study. JACC Cardiovasc Imaging. 2022. PMID: 35680213. doi:10.1016/j.jcmg.2021.12.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。